Preliminary data in a randomly selected pediatric cohort study in 8-year-olds suggested a rate of positivity to a methacholine challenge test that was unexpectedly high, roughly 30%. The current recommendation for a negative methacholine test is a 20% decrease in the forced expiratory volume in one second at a dose greater than 400 μg. This was derived from studies in adults using the obsolete English Wright nebulizer.
View Article and Find Full Text PDFThe purpose of this study was to resolve an anomalously high measure of extra-fine particle fraction (EPF) determined by the abbreviated cascade impactor possibly relevant for human respiratory tract (AIM-HRT) in the experiment described in Part 1 of this two-part series, in which the relative precision of abbreviated impactors was evaluated in comparison with a full resolution Andersen eight-stage cascade impactor (ACI). Evidence that the surface coating used to mitigate particle bounce was laterally displaced by the flow emerging from the jets of the lower stage was apparent upon microscopic examination of the associated collection plate of the AIM-HRT impactor whose cut point size defines EPF. A filter soaked in surfactant was floated on top of this collection plate, and further measurements were made using the same pressurized metered-dose inhaler-based formulation and following the same procedure as in Part 1.
View Article and Find Full Text PDFThe purpose of this study was to compare relative precision of two different abbreviated impactor measurement (AIM) systems and a traditional multi-stage cascade impactor (CI). The experimental design was chosen to provide separate estimates of variability for each impactor type. Full-resolution CIs are useful for characterizing the aerosol aerodynamic particle size distribution of orally inhaled products during development but are too cumbersome, time-consuming, and resource-intensive for other applications, such as routine quality control (QC).
View Article and Find Full Text PDFBackground: Delivery of bronchodilator to infants and small children from a pressurized metered-dose inhaler with valved holding chamber (pMDI-VHC) is limited by airway narrowness, short respiratory cycle time, and small tidal volume (V(T)). There is a need for a versatile, efficient VHC, given the variety of treatment modalities.
Methods: We tested the AeroChamber Mini VHC (the internal geometry of which is optimized for aerosol delivery, and which accepts a pMDI canister that has a dose counter) in experiments to determine differences in the delivery of hydrofluoroalkane-propelled albuterol (90 microg/actuation) during: mechanical ventilation via endotracheal tube (ETT); manual resuscitation via ETT; and spontaneous breathing via face mask.
Introduction: Electrostatic attraction of aerosolized particles to the inner walls of an aerosol holding chamber (HC) made from a nonconducting material can reduce medication delivery, particularly if there is a delay between actuation and inhalation.
Objective: Compare total emitted mass and fine-particle mass (mass of particles < 4.7 microm) of hydrofluoroalkane-propelled albuterol from similar-sized HCs manufactured from conductive material (Vortex), charge-dissipative material (AeroChamber Max), and nonconductive material (OptiChamber Advantage, ProChamber, Breathrite, PocketChamber, and ACE), with and without wash/rinse pretreatment of the HC interior with ionic detergent, and with 2-s and 5-s delays between actuation and inhalation.
The purpose of this research was to compare three different methods for the aerodynamic assessment of (1) chloroflurocarbon (CFC)--fluticasone propionate (Flovent), (2) CFC-sodium cromoglycate (Intal), and (3) hydrofluoroalkane (HFA)--beclomethasone dipropionate (Qvar) delivered by pressurized metered dose inhaler. Particle size distributions were compared determining mass median aerodynamic diameter (MMAD), geometric standard deviation (GSD), and fine particle fraction <4.7 microm aerodynamic diameter (FPF(<4.
View Article and Find Full Text PDFUnlabelled: We describe a laboratory investigation comparing the delivery of chlorofluorocarbon (CFC)- and hydrofluoroalkane (HFA)-formulated beclomethasone dipropionate (BDP) by metered-dose inhaler and holding chamber (AeroChamber HC MV) in a simulation of a mechanically ventilated adult patient.
Methods: We equipped each HC MV (n = 5) with an 8.0 mm diameter endotracheal tube (ETT), locating the HC MV in the inspiratory limb of a breathing circuit linked to a mechanical ventilator set to simulate tidal breathing at tidal volume = 830 mL, respiratory rate = 15 breaths/min, inspiratory-expiratory ratio of 1:2.
Background: Current American Thoracic Society and American Association for Respiratory Care guidelines for the delivery of aerosol agents such as methacholine chloride (MC) for bronchoprovocation testing require the use of pneumatic jet nebulizers that have well-defined droplet size and mass output. A recently developed disposable, breath-actuated nebulizer (AeroEclipse) may offer bronchoprovocation testers an alternative to existing devices.
Methods: We studied the performance of 5 AeroEclipse nebulizers with regard to mass of MC delivered with various MC solution concentrations and numbers of inhalations, using a model of adult tidal breathing.