Radiat Prot Dosimetry
November 2020
The aim of this work was to estimate patient's organ absorbed doses from pediatric helical head computed tomography (CT) examinations using the Size-Specific Dose Estimate (SSDE) methodology and to determine organ dose to SSDE conversion coefficients for clinical routine. Patient-specific organ and tissue absorbed doses from 139 Head CT scans performed in pediatric patients from 0 to 15 years old in a Public Hospital in Tunja, Colombia were estimated. The calculations were made through Monte Carlo simulations, based on patient-specific information, dosimetric CT quantities (CTDIvol, DLP) and age-specific computational human phantoms matched to patients on the basis of gender and size.
View Article and Find Full Text PDFBiomed Phys Eng Express
November 2019
Recent epidemiological studies suggested to lower the threshold dose for radiation induced cataract in the eye lens. Therefore, eye lens radiation protection became to play a more important role in personal dosimetry. The main objective of this work is to propose a new methodology for prototyping and benchmarking of an eye lens dosimter based on the equivalent dose to the sensitive part of the eye lens, using CAD Software and Geant4 Monte Carlo simulations with mesh modelling and 3D printing.
View Article and Find Full Text PDFThe purpose of bowtie filters in CT scanners is to homogenize the x-ray intensity measured by the detectors in order to improve the image quality and at the same time to reduce the dose to the patient because of the preferential filtering near the periphery of the fan beam. For CT dosimetry, especially for Monte Carlo calculations of organ and tissue absorbed doses to patients, it is important to take the effect of bowtie filters into account. However, material composition and dimensions of these filters are proprietary.
View Article and Find Full Text PDFThe purpose of this study is the development of paediatric reference phantoms for newborn and 1-year-old infants to be used for the calculation of organ and tissue equivalent doses in radiation protection. The study proposes a method for developing anatomically highly sophisticated paediatric phantoms without using medical images. The newborn and 1-year-old hermaphrodite phantoms presented here were developed using three-dimensional (3D) modelling software applied to anatomical information taken from atlases, textbooks and images provided by the Department of Anatomy of the Federal University of Pernambuco, Brazil.
View Article and Find Full Text PDFTwo skeletal dosimetry methods using µCT images of human bone have recently been developed: the paired-image radiation transport (PIRT) model introduced by researchers at the University of Florida (UF) in the US and the systematic–periodic cluster (SPC) method developed by researchers at the Federal University of Pernambuco in Brazil. Both methods use µCT images of trabecular bone (TB) to model spongiosa regions of human bones containing marrow cavities segmented into soft tissue volumes of active marrow (AM), trabecular inactive marrow and the bone endosteum (BE), which is a 50 µm thick layer of marrow on all TB surfaces and on cortical bone surfaces next to TB as well as inside the medullary cavities. With respect to the radiation absorbed dose, the AM and the BE are sensitive soft tissues for the induction of leukaemia and bone cancer, respectively.
View Article and Find Full Text PDFPurpose: The purpose of this study is the development of reference pediatric phantoms for 5- and 10-year-old children to be used for the calculation of organ and tissue equivalent doses in radiation protection.
Methods: The study proposes a method for developing anatomically highly sophisticated pediatric phantoms without using medical images. The 5- and 10-year-old male and female phantoms presented here were developed using 3D modeling software applied to anatomical information taken from atlases and textbooks.
Computational anthropomorphic human phantoms are useful tools developed for the calculation of absorbed or equivalent dose to radiosensitive organs and tissues of the human body. The problem is, however, that, strictly speaking, the results can be applied only to a person who has the same anatomy as the phantom, while for a person with different body mass and/or standing height the data could be wrong. In order to improve this situation for many areas in radiological protection, this study developed 18 anthropometric standing adult human phantoms, nine models per gender, as a function of the 10th, 50th and 90th mass and height percentiles of Caucasian populations.
View Article and Find Full Text PDFWhen the human body is exposed to ionizing radiation, among the soft tissues at risk are the active marrow (AM) and the bone endosteum (BE) located in tiny, irregular cavities of trabecular bone. Determination of absorbed fractions (AFs) of energy or absorbed dose in the AM and the BE represent one of the major challenges of dosimetry. Recently, at the Department of Nuclear Energy at the Federal University of Pernambuco, a skeletal dosimetry method based on µCT images of trabecular bone introduced into the spongiosa voxels of human phantoms has been developed and applied mainly to external exposure to photons.
View Article and Find Full Text PDFDoes the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as in the supine posture. The recently published FASH (female adult mesh) and MASH (male adult mesh) phantoms have the standing posture. In a first step, both phantoms were updated with respect to their anatomy: glandular tissue was separated from adipose tissue in the breasts, visceral fat was separated from subcutaneous fat, cartilage was segmented in ears, nose and around the thyroid, and the mass of the right lung is now 15% greater than the left lung.
View Article and Find Full Text PDFAmong computational models, voxel phantoms based on computer tomographic (CT), nuclear magnetic resonance (NMR) or colour photographic images of patients, volunteers or cadavers have become popular in recent years. Although being true to nature representations of scanned individuals, voxel phantoms have limitations, especially when walled organs have to be segmented or when volumes of organs or body tissues, like adipose, have to be changed. Additionally, the scanning of patients or volunteers is usually made in supine position, which causes a shift of internal organs towards the ribcage, a compression of the lungs and a reduction of the sagittal diameter especially in the abdominal region compared to the regular anatomy of a person in the upright position, which in turn can influence organ and tissue absorbed or equivalent dose estimates.
View Article and Find Full Text PDFFemale and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been developed in the first part of this study using 3D animation software and anatomical atlases to replace the image-based FAX06 and the MAX06 voxel phantoms. 3D modelling methods allow for phantom development independent from medical images of patients, volunteers or cadavers. The second part of this study investigates the dosimetric implications for organ and tissue equivalent doses due to the anatomical differences between the new and the old phantoms.
View Article and Find Full Text PDF