Bioengineering (Basel)
December 2023
Subject-specific hip capsule models could offer insights into impingement and dislocation risk when coupled with computer-aided surgery, but model calibration is time-consuming using traditional techniques. This study developed a framework for instantaneously generating subject-specific finite element (FE) capsule representations from regression models trained with a probabilistic approach. A validated FE model of the implanted hip capsule was evaluated probabilistically to generate a training dataset relating capsule geometry and material properties to hip laxity.
View Article and Find Full Text PDFThe forces applied during a spinal manipulation produce a neuromuscular response in the paraspinal muscles. A systematic evaluation of the factors involved in producing this muscle activity provides a clinical insight. The purpose of this study is to quantify the effect of (manipulation sequence and manipulation site) and (muscle layer, muscle location, and muscle side) on the neuromuscular response to spinal manipulation.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
May 2024
The hip capsule is a ligamentous structure that contributes to hip stability. This article developed specimen-specific finite element models that replicated internal-external (I-E) laxity for ten implanted hip capsules. Capsule properties were calibrated to minimize root mean square error (RMSE) between model and experimental torques.
View Article and Find Full Text PDFRepresentative data of asymptomatic, native-knee kinematics is important when studying changes in knee function across the lifespan. High-speed stereo radiography (HSSR) provides a reliable measure of knee kinematics to <1 mm of translation and 1° of rotation, but studies often have limited statistical power to make comparisons between groups or measure the contribution of individual variability. The purpose of this study is to examine in vivo condylar kinematics to quantify the transverse center-of-rotation, or pivot, location across the flexion range and challenge the medial-pivot paradigm in asymptomatic knee kinematics.
View Article and Find Full Text PDFBackground: Condyle-spanning plate-screw constructs have shown potential to lower the risks of femoral refractures after the healing of a primary Vancouver type B1 periprosthetic femoral fracture. Limited information exists to show how osteoporosis (a risk factor for periprosthetic femoral fractures) may affect the plate fixation during activities of daily living.
Methods: Using total hip arthroplasty and plate-implanted finite element models of three osteoporotic femurs, this study simulated physiological loads of three activities of daily living, as well as osteoporosis associated muscle weakening, and compared the calculated stress/strain, load transfer and local stiffness with experimentally validated models of three healthy femurs.
Secondary femoral fractures after the successful plate-screw fixation of a primary Vancouver type B1 periprosthetic femoral fracture (PFF) have been associated with the altered state of stress/strain in the femur as the result of plating. The laterally implanted condyle-spanning plate-screw constructs have shown promises clinically in avoiding secondary bone and implant failures as compared with shorter diaphyseal plates. Though the condyle-spanning plating has been hypothesized to avoid stress concentration in the femoral diaphysis through increasing the working length of the plate, biomechanical evidence is lacking on how plate length may impact the stress/strain state of the implanted femur.
View Article and Find Full Text PDFKinematic tracking of healthy joints in radiography sequences is frequently performed by maximizing similarities between computed perspective projections of 3D computer models and corresponding objects' appearances in radiographic images. Significant human effort associated with manual tracking presents a major bottleneck in biomechanics research methods and limits the scale of target applications. The current work introduces a method for fully-automatic tracking of tibiofemoral and patellofemoral kinematics in stereo-radiography sequences for subjects performing dynamic activities.
View Article and Find Full Text PDFPlate fractures after fixation of a Vancouver Type B1 periprosthetic femoral fracture (PFF) are difficult to treat and could lead to severe disability. However, due to the lack of direct measurement of in vivo performance of the PFF fixation construct, it is unknown whether current standard mechanical tests or previous experimental and computational studies have appropriately reproduced the in vivo mechanics of the plate. To provide a basis for the evaluation and development of appropriate mechanical tests for assessment of plate fracture risk, this study applied loads of common activities of daily living (ADLs) to implanted femur finite element (FE) models with PFF fixation constructs with an existing or a healed PFF.
View Article and Find Full Text PDFGait analysis based on inertial sensors has become an effective method of quantifying movement mechanics, such as joint kinematics and kinetics. Machine learning techniques are used to reliably predict joint mechanics directly from streams of IMU signals for various activities. These data-driven models require comprehensive and representative training datasets to be generalizable across the movement variability seen in the population at large.
View Article and Find Full Text PDFJoint contact and muscle forces estimated with musculoskeletal modeling techniques offer useful metrics describing movement quality that benefit multiple research and clinical applications. The expensive processing of laboratory data associated with generating these outputs presents challenges to researchers and clinicians, including significant time and expertise requirements that limit the number of subjects typically evaluated. The objective of the current study was to develop and compare machine learning techniques for rapid, data-driven estimation of musculoskeletal metrics from derived gait lab data.
View Article and Find Full Text PDFDislocation remains the leading indication for revision of total hip arthroplasty (THA). The objective of this study was to use a computational model to compare the overall resistance to both anterior and posterior dislocation for the available THA constructs commonly considered by surgeons attempting to produce a stable joint. Patient-specific musculoskeletal models of THA patients performing activities consistent with anterior and posterior dislocation were developed to calculate joint contact forces and joint positions used for simulations of dislocation in a finite element model of the implanted hip that included an experimentally calibrated hip capsule representation.
View Article and Find Full Text PDFFemoral strain is indicative of the potential for bone remodeling (strain energy density, SED) and periprosthetic femoral fracture (magnitude of principal strains) after total hip arthroplasty (THA). Previous modeling studies have evaluated femoral strains in THA-implanted femurs under gait loads including both physiological hip contact force and femoral muscle forces. However, experimental replication of the complex muscle forces during activities of daily living (ADLs) is difficult for in vitro assessment of femoral implant or fixation hardware.
View Article and Find Full Text PDFQuantitative assessments of patient movement quality in osteoarthritis (OA), specifically spatiotemporal gait parameters (STGPs), can provide in-depth insight into gait patterns, activity types, and changes in mobility after total knee arthroplasty (TKA). A study was conducted to benchmark the ability of multiple deep neural network (DNN) architectures to predict 12 STGPs from inertial measurement unit (IMU) data and to identify an optimal sensor combination, which has yet to be studied for OA and TKA subjects. DNNs were trained using movement data from 29 subjects, walking at slow, normal, and fast paces and evaluated with cross-fold validation over the subjects.
View Article and Find Full Text PDFInstability and dislocation remain leading indications for revision of total hip arthroplasty (THA). Many studies have addressed the links between implant design and dislocation; however, an understanding of the impact of alignment and kinematic variability on constraint of modern THA constructs to provide joint stability is needed. The objective of this study is to provide objective data to be considered in the treatment algorithm to protect against joint instability.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
August 2020
The objective of this study was to develop a probabilistic representation of the hip capsule, which is calibrated to experimental capsular torque-rotation behavior and captures the observed variability for use in population-based studies. A finite element model of the hip capsule was developed with structures composed of a fiber-reinforced membrane, represented by 2D quadrilateral elements embedded with tension-only non-linear spring. An average capsule representation was developed by calibrating ligament properties (linear stiffness, reference strain) so that torque-rotation behavior matched mean cadaveric data.
View Article and Find Full Text PDFLower extremity muscle strength training is a focus of rehabilitation following total hip arthroplasty (THA). Strength of the hip abductor muscle group is a predictor of overall function following THA. The purpose of this study was to investigate the effects of hip abductor strengthening following rehabilitation on joint contact forces (JCFs) in the lower extremity and low back during a high demand step down task.
View Article and Find Full Text PDFBackground: Component alignment is an important consideration in total hip arthroplasty. The impact of changes in alignment on muscle forces and joint contact forces during dynamic tasks are not well understood, and have the potential to influence surgical decision making. The objectives of this study were to assess the impact of femoral head/stem and cup component placement on hip muscle and joint contact forces during tasks of daily living and to identify which alignment parameters have the greatest impact on joint loading.
View Article and Find Full Text PDFJ Verif Valid Uncertain Quantif
September 2017
Joint kinetic measurement is a fundamental tool used to quantify compensatory movement patterns in participants with transtibial amputation (TTA). Joint kinetics are calculated through inverse dynamics (ID) and depend on segment kinematics, external forces, and both segment and prosthetic inertial parameters (PIPS); yet the individual influence of PIPs on ID is unknown. The objective of this investigation was to assess the importance of parameterizing PIPs when calculating ID using a probabilistic analysis.
View Article and Find Full Text PDFJ Manipulative Physiol Ther
May 2016
Objective: The purpose of this study was to determine electromyographic threshold parameters that most reliably characterize the muscular response to spinal manipulation and compare 2 methods that detect muscle activity onset delay: the double-threshold method and cross-correlation method.
Methods: Surface and indwelling electromyography were recorded during lumbar side-lying manipulations in 17 asymptomatic participants. Muscle activity onset delays in relation to the thrusting force were compared across methods and muscles using a generalized linear model.
J Manipulative Physiol Ther
May 2016
Objective: The purpose of this study was to evaluate differences in muscle activity in participants with and without low back pain during a side-lying lumbar diversified spinal manipulation.
Methods: Surface and indwelling electromyography at eight muscle locations were recorded during lumbar side-lying manipulations in 20 asymptomatic participants and 20 participants with low back pain. The number of muscle responses and muscle activity onset delays in relation to the manipulation impulse were compared in the 2 pain groups using mixed linear regressions.
Musculoskeletal models are powerful tools that allow biomechanical investigations and predictions of muscle forces not accessible with experiments. A core challenge modelers must confront is validation. Measurements of muscle activity and joint loading are used for qualitative and indirect validation of muscle force predictions.
View Article and Find Full Text PDFUncertainty that arises from measurement error and parameter estimation can significantly affect the interpretation of musculoskeletal simulations; however, these effects are rarely addressed. The objective of this study was to develop an open-source probabilistic musculoskeletal modeling framework to assess how measurement error and parameter uncertainty propagate through a gait simulation. A baseline gait simulation was performed for a male subject using OpenSim for three stages: inverse kinematics, inverse dynamics, and muscle force prediction.
View Article and Find Full Text PDFJ Manipulative Physiol Ther
May 2013
Objectives: The purposes of this study included the following: (1) to predict L3 contact force during side-lying lumbar manipulation by combining direct and indirect measurements into a single mathematical framework and (2) to assess the accuracy and confidence of predicting L3 contact force using common least squares (CLS) and weighted least squares (WLS) methods.
Methods: Five participants with no history of lumbar pain underwent 10 high-velocity, low-amplitude lumbar spinal manipulations at L3 in a side-lying position. Data from 5 low-force criterion standard trials where the L3 contact force was directly measured were used to generate participant-specific force prediction algorithms.
While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no studies have statistically evaluated the consistency of the accuracy across motions of varying intensity or between degrees of freedom.
View Article and Find Full Text PDF