Osteoimmunology is the crosstalk between cells from the immune and skeletal systems, suggesting a role of pro-inflammatory cytokines in the stimulation of osteoclast activity. Endotoxin or bacterial challenges to inflammatory cells are directly relevant to dental implant pathologies involving bone resorption, such as osseointegration failure and peri-implantitis. While the endotoxin amount on implant devices is regulated by standards, it is unknown whether commercially available dental implants elicit different levels of adherent-endotoxin stimulated cytokines.
View Article and Find Full Text PDFMicrorough, doubly acid etched titanium surfaces (Ti) were further modified by amination and covalent coupling of fibrillar collagen type I (ColTi). Human Mesenchymal Cells (HMC) adhesion and growth, and relevant osteogenic differentiation in nonosteogenic (basal) medium were evaluated by fluorescence microscopy, scanning electron microscopy, and RT-PCR for a three-week period. Results show strongly enhanced HMC adhesion and cell density at short experimental time on ColTi, together with complete spreading of the cell body over the microrough surface topography.
View Article and Find Full Text PDFThe goal of the study was the evaluation of the effect of biochemical surface modification by collagen on the bone response to acid-etched titanium surfaces. Fibrillar type I porcine collagen was adsorbed and covalently linked to acid-etched Ti disks and implants. Adhesion, growth, and specific alkaline phosphatase (ALP) activity of osteoblast-like SaOS2 cells were evaluated.
View Article and Find Full Text PDFThe surface of an implant device can be modified by immobilizing biological molecules on it to improve its integration into the host tissue. We have previously demonstrated that enzymatically tailored plant pectins are promising nanocoatings for biomaterials. This study investigates whether a coating of modified hairy region (rhamnogalacturonan-I) from apple pectin (MHR-alpha) which has anti-adhesive properties can inhibit the generation of inflammatory mediators by lipopolysaccharide (LPS)-activated macrophages.
View Article and Find Full Text PDFThe goal of this study was the in vivo evaluation of nanoporous titanium (Ti) implants bearing a covalently linked surface hyaluronan (HA) layer. Implant surface topography and surface chemistry were previously evaluated by scanning electron microscopy and X-ray photoelectron spectroscopy. Results showed that the surface modification process did not affect surface topography, yielding a homogeneously HA-coated nanotextured implant surface.
View Article and Find Full Text PDFImproved biocompatibility and performance of biomedical devices can be achieved through the incorporation of bioactive molecules on device surfaces. Five structurally distinct pectic polysaccharides (modified hairy regions (MHRs)) were obtained by enzymatic liquefaction of apple (MHR-B, MHR-A and MHR-alpha), carrot (MHR-C) and potato (MHR-P) cells. Polystyrene (PS) Petri dishes, aminated by a plasma deposition process, were surface modified by the covalent linking of the MHRs.
View Article and Find Full Text PDFJ Biomed Mater Res A
September 2008
Membranes in artificial organs and scaffolds for tissue engineering are often coated with biomimetic molecules (e.g., collagen) to improve their biocompatibility and promote primary cell adhesion and differentiation.
View Article and Find Full Text PDFThe goal of the study was the evaluation of the effect of modification of titanium implants by acrylic acid surface grafting-collagen I coupling. Tests were performed on titanium samples treated by galvanostatic anodization to create a porous surface topography. Surface characterization by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) confirms the biochemical modification of the surface and shows a surface topography characterized by pores mostly below 1 mum diameter.
View Article and Find Full Text PDFPolystyrene Petri dishes, aminated by a plasma deposition process, were surface modified by the covalent linking of two different enzymatically modified hairy regions (HRs) from pectin containing, for example, rhamnogalacturonan-I and xylogalacturonan structural elements. The two polysaccharide preparations share the same structural elements of apple pectin, but the relative amounts and lengths of the neutral side chains present differ. Surface analysis by X-ray photoelectron spectroscopy, contact angle measurement, and atomic force microscope (AFM) force-separation curves was used to characterize the effects on surface chemistry and interfacial forces of the surface modification process.
View Article and Find Full Text PDFBiomed Pharmacother
October 2004
Two different cationic antimicrobial molecules, chlorhexidine (CH) and poly(hexamethylenebiguanide) (PH), were adsorbed from aqueous solution to titanium implant devices surface-modified by the covalent coupling of collagen on a polyanionic acrylic acid overlayer. Results show that more antimicrobial was adsorbed on surface modified implants as compared to control titanium devices. Moreover, the kinetic of release was affected by the interaction between the polyanionic overlayer and the cationic antimicrobial, leading to slower kinetic of release in the case of CH and stable adsorption in the case of polycationic PH .
View Article and Find Full Text PDFCollagen was covalently linked to the surface of Titanium (Ti) by a surface modification process involving deposition of a thin film from hydrocarbon plasma followed by acrylic acid grafting. The composition and properties of surface-modified Ti were investigated by a number of surface sensitive techniques: XPS, ATR-IR, atomic force microscopy and AFM force-separation curves. In vitro tests were performed to check samples cytotoxicity and the behavior of osteoblast-like SaOS-2 cells.
View Article and Find Full Text PDF