Background: Patient-reported outcome (PRO) measures are essential for evaluating disease-related quality of life. The International Hip Outcome Tool 12 (iHOT12) assesses various aspects of hip-related symptoms, function, sports participation, and social limitations. This study aimed to adapt and validate an Italian version of the iHOT12 according to COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) guidelines.
View Article and Find Full Text PDFBackground: Tibiofemoral components rotational congruency affects the total knee arthroplasty (TKA) success. The smart insert sensor (I-S) helps to establish tibial component rotation reciprocally to a fixed femoral rotation. We aimed (1) to validate the use of I-S as a possible tool to reach reproducible reciprocal femorotibial rotation (RftR) in TKA independently from anatomic landmarks, reducing outliers in combined and mismatched femorotibial rotation (CftR and MMftR, respectively) positioning and (2) to validate the "curve-on-curve" method for a specific type of asymmetrical tibial component.
View Article and Find Full Text PDFThe medial unicompartmental knee arthroplasty (mUKA) has been recognized as an excellent treatment for medial knee osteoarthritis. The posterior tibial slope (PTS) is measured radiographically with the intramedullary axis (IMA) to the tibial baseplate on the sagittal plane radiograph. However, in most computer-navigated or robotic mUKAs, the PTS is set from a transmalleolar axis (TMA).
View Article and Find Full Text PDFBackground: Although total knee replacement (TKR) surgery has succeeded in improving pain and deformity, a proportion of patients remain incompletely satisfied with their outcome. This prospective study aims to assess the survivorship, clinical, and radiological outcomes using a novel 'kinematic retaining' (KR) implant.
Methods: 156 patients underwent TKR surgery for primary osteoarthritis using the Physica KR implant at three European Centres.
Patients with Haemophilia (PWH) need orthopaedic treatments and often they undergo surgery. Classically, PWH with inhibitors have to face such procedures earlier than other patients. Major orthopaedic surgery is not easy and complications are frequent.
View Article and Find Full Text PDFBackground And Objective: Proximal femoral replacement due to revision hip arthroplasty or catastrophic proximal femur fracture fixation failures with considerable proximal femur bone loss can lead to a substantial loss of function of the soft tissue around the hip and the abductor muscles in particular. Surgical techniques of gluteus medius repair and/or abductor mechanism reattachment/reconstruction are widely debated in the literature, but it is quite rarely dealt with in the context of megaprosthesis and femoral reconstruction, particularly in non-oncologic patients. The aim of this study is to present a narrative review of the literature on techniques for abductor reattachment in proximal femoral replacement for non-oncological reconstructions.
View Article and Find Full Text PDFBackground And Purpose: The aim of this study was to evaluate whether this system is associated with a reduced rate of failure and complications in patients treated for proximal femoral fractures with intramedullary nailing.
Materials And Methods: 742 Patients with AO-OTA 31-A intertrochanteric fractures were enrolled at a single Institution. Functional evaluation was assessed through the Functional Independence Measure (FIM™) instrument and Parker's New Mobility Score (NMS).
Introduction: Considering the advances in haemophilia management and treatment observed in the last decades, a new set of value-based outcome indicators is needed to assess the quality of care and the impact of these medical innovations.
Aim: The Value-Based Healthcare in Haemophilia project aimed to define a set of clinical outcome indicators (COIs) and patient-reported outcome indicators (PROIs) to assess quality of care in haemophilia in high-income countries with a value-based approach to inform and guide the decision-making process.
Methods: A Value-based healthcare approach based on the available literature, current guidelines and the involvement of a multidisciplinary group of experts was applied to generate a set of indicators to assess the quality of care of haemophilia.
Groin pain syndrome (GPS) is a controversial topic in Sports Medicine. The GPS Italian Consensus Conference on terminology, clinical evaluation and imaging assessment of groin pain in athletes was organized by the Italian Society of Arthroscopy in Milan, on 5 February 2016. In this Consensus Conference (CC) GPS etiology was divided into 11 different categories for a total of 63 pathologies.
View Article and Find Full Text PDFPurpose: The aim of this study was to evaluate the relationship between the Löwenstein Lateral view and the True Lateral view for the positioning of the cephalic hip screw, through a cadaveric study.
Materials And Methods: We placed two Kirschner wires in eight femur specimens using an Antero-Posterior view, Löwenstein Lateral view and True Lateral view. The distances between the Kirschner wires and the anterior, posterior, superior and inferior cortex were measured in all projections.
(1) Background: Total Knee Arthroplasty (TKA) in patient with haemophilia (PWH) has usually been performed with the use of cobalt-chrome femoral and titanium tibial components, coupled with standard polyethylene (PE) inserts. The aim of this retrospective study was to evaluate the long-term outcomes and survival rates of TKA in a series of consecutive PWH affected by severe knee arthropathy at a single institution. (2) Methods: We followed 65 patients undergoing 91 TKA, implanted using the same implant, characterized by an oxidized zirconium femoral component, coupled with a titanium tibial component, and a highly crosslinked PE.
View Article and Find Full Text PDFThe Medical Directors of nine Italian Hemophilia Centers reviewed and discussed the key issues concerning the replacement therapy of hemophilia patients during a one-day consensus conference held in Rome one year ago. Particular attention was paid to the replacement therapy needed for surgery using continuous infusion (CI) versus bolus injection (BI) of standard and extended half-life Factor VIII (FVIII) concentrates in severe hemophilia A patients. Among the side effects, the risk of development of neutralizing antibodies (inhibitors) and thromboembolic complications was addressed.
View Article and Find Full Text PDFEmicizumab is a humanized recombinant bispecific antibody, bridging together activated factor IX (FIXa) and factor X (FX), thus mimicking the activity of FVIII in vivo. Emicizumab is designed for long-term prophylaxis in patients with severe hemophilia A with and without inhibitors. This approach provides constant protection, with significant reduction in bleeding rate and improved quality of life.
View Article and Find Full Text PDFBackground: Hip hemiarthroplasty dislocation is a devastating complication. Among other preoperative risk factors, acetabular morphology has been rarely studied. The purpose of the study was to evaluate the influence of preoperative native acetabular morphology on hemiarthroplasty dislocation.
View Article and Find Full Text PDFIntroduction: Current treatment for haemophilia A involves factor VIII replacement or non-replacement (emicizumab) therapies, neither of which permanently normalise factor VIII levels. Gene therapy using adeno-associated viral (AAV) vectors is an emerging long-term treatment strategy for people with severe haemophilia A (PwSHA) that is likely to be available for clinical use in the near future.
Aim: This article proposes practical guidelines for the assessment, treatment, and follow-up of potential PwSHA candidates for AAV-based gene therapy.
Background: Although predictable implant longevity in total knee replacement (TKR) is now established, work continues to satisfy the demands of patients who seek full restoration of the painless function of the native knee following TKR. This prospective study examines the early clinical outcomes of 156 patients implanted with a novel 'kinematic-retaining' (KR) implant.
Methods: 156 Physica KR TKRs were implanted for primary osteoarthritis at three European centres.
Introduction: Lesser trochanter (LT) fixation to restore the continuity of the posteromedial fragment using a cerclage wire has been reported to provide a more stable reduction in the treatment of unstable femoral neck fractures with LT involvement. However, LT fixation is not commonly performed due to the complications associated with the traditional monofilament cerclage metal wires. In this study, we investigate the clinical and radiological outcomes of a new technique for LT fixation in conjunction with Intramedullary (IM) fixation with nail and screws when compared to isolated IM fixation.
View Article and Find Full Text PDFBackground: Knee varus alignment represents a notorious cause of knee osteoarthritis. It can be caused by tibial deformity, combined tibial-femoral deformity and/or ligament imbalance. Understanding malalignment is crucial in total knee arthroplasty to restore frontal plane neutral mechanical axis.
View Article and Find Full Text PDFIntroduction: Periprosthetic femoral fracture around hip arthroplasty are growing in the world, nevertheless management and treatment options for fractures "around the stem" are still debated due to lack of high-level studies.
Materials And Method: A 85-item survey were fill out by 40 Italian Orthopedic Surgeon member of SIOT (Società Italiana di Ortopedia e Traumatologia) and AIR (Associazione Italiana Riprotesizzazione) to assess their current opinion in the management of type B periprosthetic femoral fractures. Responses were summarized using proportions, and further stratified by practice type, case volume, surgeon age, and fellowship training.
Although synovitis is recognized as a marker of joint disease activity, its periodic assessment is not included in routine clinical surveillance of patients with haemophilia (PwH). In order to evaluate the current knowledge and to identify controversial issues, a preliminary literature search by the Musculoskeletal Committee of the Italian Association of Haemophilia Centres (AICE) has been conducted. Statements have been established and sent to the Italian AICE members to collect their level of agreement or disagreement by a Delphi process.
View Article and Find Full Text PDFAims: In case of severe bone loss, acetabular revision can be challenged using extra porous pure trabecular titanium (TT) revision cups designed to ensure enhanced iliac and ischiatic purchase. Aim of the study is to report on the clinical and radiological results of a TT acetabular component, evaluating functional outcome, restoration of the hip center of rotation and osteointegration.
Methods: 85 patients, who underwent acetabular revision with a TT revision cup system between October 2009 and December 2018, were included in a retrospective study.
Purpose: (1) To investigate correlations between different types of FAI and the ratio of acetabular volume (AV) to femoral head volume (FV) on MR arthrography. (2) To assess 2D/3D measurements in identifying different types of FAI by means of cut-off values of AV/FV ratio (AFR).
Materials And Methods: Alpha angle, cranial acetabular version, acetabular depth, lateral center edge angle, AV, and FV of 52 hip MR arthrography were measured.
Background: The use of proximal femoral replacements (PFR) has been recently described for catastrophic internal fixation failures. PFR is an attractive treatment option because it is technically straightforward and allows for immediate mobilization of the patient. The aim of the study was to determine the survivorship, functional outcome and complications' rate in a group of elderly patients who underwent proximal femoral replacement as a salvage treatment after femur cephalomedullary nails' mechanical failures.
View Article and Find Full Text PDFAim Uncommon and rare hip diseases are sources of pain and functional limitation particularly in young patients. Some of these conditions may be nowadays treated by arthroscopy due to the expertise and technical tips that high-volume hip arthroscopies have achieved during the last decades ensuring a wider range of indications for such a procedure. The aim of this study was to evaluate clinical results of arthroscopy in treating uncommon or rare diseases of the hip at a single Institution.
View Article and Find Full Text PDF