Background: Patients presenting with periprosthetic osteolysis or fracture between ipsilateral hip and knee arthroplasties are challenging to treat successfully. Long-stem implants, osteopenic bones, and patient comorbidities all represent considerable surgical challenges. Poor results of fracture fixation in this group, coupled with the desire to retain well-performing implants and minimize soft-tissue trauma led to the developmentof the custom cement-over megaprostheses (CCOM).
View Article and Find Full Text PDFThe design freedom afforded by additive manufacturing (AM) is now being leveraged across multiple applications, including many in the fields of imaging for personalised medicine. This study utilises a pellet-fed, multi-material AM machine as a route to fabricating new imaging phantoms, used for developing and refining algorithms for the detection of subtle soft tissue anomalies. Traditionally comprising homogeneous materials, higher-resolution scanning now allows for heterogeneous, multi-material phantoms.
View Article and Find Full Text PDFIntroduction: It is increasingly accepted that young people need to be centrally involved in research on issues that affect them. The aim of this study was to explore young people's perceptions of the benefits for them of being involved in mental health research and the processes that enabled these benefits.
Methods: Qualitative interviews were conducted by co-researchers (young people with lived experience and/or interest in mental health) with 13 young people (aged 13-24 years) who had experience of being involved in mental health research when they were between 11 and 16 years of age.
Background: There are limited randomized controlled trials with long-term outcomes comparing autologous chondrocyte implantation (ACI) versus alternative forms of surgical cartilage management within the knee.
Purpose: To determine at 5 years after surgery whether ACI was superior to alternative forms of cartilage management in patients after a failed previous treatment for chondral or osteochondral defects in the knee.
Study Design: Randomized controlled trial; Level of evidence, 1.
Introduction: Custom acetabular components have become an established method of treating massive acetabular bone defects in hip arthroplasty. Complication rates, however, remain high and migration of the cup is still reported. Ischial screw fixation (IF) has been demonstrated to improve mechanical stability for non-custom, revision arthroplasty cup fixation.
View Article and Find Full Text PDFJ Pharmacol Toxicol Methods
November 2021
Idiopathic pulmonary fibrosis (IPF) is a disease that causes scarring and destruction of lung tissue that is ultimately fatal. There is a need to develop improved treatments for IPF. One problem with identifying novel treatments of IPF is the poor predictability of current preclinical models.
View Article and Find Full Text PDFPurpose: Hip precautions are movement restrictions that are often advised following primary total hip arthroplasty (PTHA) for osteoarthritis (OA), but there is limited evidence supporting their effectiveness in preventing dislocation. This study aimed to explore the clinical reasoning behind the continuation and discontinuation of hip precautions following PTHA for OA.
Materials And Methods: Semi-structured interviews were conducted with therapists and surgeons at six centres using precautions and six centres not using precautions across secondary or tertiary NHS sites in England.
Background: Multiply revised total knee arthroplasties (TKAs) may present with large anterior soft tissue defects, which can be challenging to reconstruct. In the rare cases where local flaps are insufficient, we use free latissimus dorsi (LD) myocutaneous flaps to achieve soft tissue coverage. This study looked to determine implant survivorship, infection status, and patient-reported outcomes of patients undergoing simultaneous revision TKA and LD flaps in a tertiary unit.
View Article and Find Full Text PDFBackground: Autologous chondrocyte implantation (ACI) is a NICE-approved technique to regenerate hyaline cartilage in chondral and osteochondral defects (OCDs). The drawbacks of ACI include that it requires a two-stage approach, involves a lengthy rehabilitation process and is expensive. Bone marrow harvest with mesenchymal stem cell transplantation using a single-stage procedure and an accelerated rehabilitation programme has been developed to overcome this.
View Article and Find Full Text PDFThe coronavirus disease 2019 (COVID-19) pandemic caused by SARS-CoV-2 infections has led to a substantial unmet need for treatments, many of which will require testing in appropriate animal models of this disease. Vaccine trials are already underway, but there remains an urgent need to find other therapeutic approaches to either target SARS-CoV-2 or the complications arising from viral infection, particularly the dysregulated immune response and systemic complications which have been associated with progression to severe COVID-19. At the time of writing, in vivo studies of SARS-CoV-2 infection have been described using macaques, cats, ferrets, hamsters, and transgenic mice expressing human angiotensin I converting enzyme 2 (ACE2).
View Article and Find Full Text PDFBackground: FluoroSim, a novel fluoroscopic simulator, can be used to practice dynamic hip screw (DHS) guidewire insertion in a high-fidelity clinical scenario. Our aim was to demonstrate a training effect in undergraduate medical students who are not familiar with this operation and its simulation.
Methods: Forty-five undergraduate medical students were recruited and randomized to either training (n = 23) or control (n = 22) cohorts.
Idiopathic pulmonary fibrosis (IPF) is a fatal interstitial lung disease with a poor prognosis and limited treatment options. Many compounds have shown efficacy in preclinical models of this condition, but only pirfenidone and nintedanib have been approved for clinical use. It is widely accepted that the current animal models of IPF need to be improved and in this review we have critically evaluated the current state of play of preclinical models of IPF and discuss the challenges facing this field.
View Article and Find Full Text PDFObjectives: Treatment escalation plans (TEPs) are vital in communicating a ceiling of care. However, many patients still deteriorate and die without a pre-established ceiling of care for attending clinicians to rely on. We aimed to increase the proportion of suitable patients that have TEPs in place in a rural district general hospital.
View Article and Find Full Text PDFBackground and purpose - Simulation is an adjunct to surgical education. However, nothing can accurately simulate fluoroscopic procedures in orthopedic trauma. Current options for training with fluoroscopy are either intraoperative, which risks radiation, or use of expensive and unrealistic virtual reality simulators.
View Article and Find Full Text PDFBackground: Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures.
View Article and Find Full Text PDFAims: Pigmented villonodular synovitis (PVNS) is a rare, locally aggressive and potentially recurrent synovial disease. We present the largest single-centre experience of knee PVNS. Our aim was to evaluate our tertiary hospital's experience in the management of knee PVNS.
View Article and Find Full Text PDFPurpose: The first aim of this study was to assess plan quality using a conformity index (CI) and analyse its influence on patient outcome. The second aim was to identify whether clinical and technological factors including planning treatment volume (PTV) volume and treatment delivery method could be related to the CI value.
Methods And Materials: By extending the original concept of the mean distance to conformity (MDC) index, the OverMDC and UnderMDC of the 95 % isodose line (50Gy prescribed dose) to the PTV was calculated for 97 patients from the UK SCOPE 1 trial (ISCRT47718479).
Purpose: Using radiobiological modelling to estimate normal tissue toxicity, this study investigates the effects of dose escalation for concurrent chemoradiation therapy (CRT) in lower third oesophageal tumours on the stomach.
Methods And Materials: 10 patients with lower third oesophageal cancer were selected from the SCOPE 1 database (ISCRT47718479) with a mean planning target volume (PTV) of 348 cm(3). The original 3D conformal plans (50 Gy3D) were compared to newly created RapidArc plans of 50 GyRA and 60 GyRA, the latter using a simultaneous integrated boost (SIB) technique using a boost volume, PTV2.
Introduction. Metal-on-metal (MoM) hip resurfacings have been associated with a variety of complications resulting from adverse reaction to metal debris. Pseudotumors have rarely been reported to cause deep venous thrombosis (DVT).
View Article and Find Full Text PDFThe long term biological effects of wear products following total hip arthroplasty (THA) are unclear. However, the indications for THA are expanding, with increasingly younger patients undergoing the procedure. This prospective, randomised study compared two groups of patients undergoing THA after being randomised to receive one of two different bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal (MoM) n = 23.
View Article and Find Full Text PDFBackground: Over one million patients worldwide are estimated to have a metal-on-metal hip arthroplasty. To improve the management of these patients and reduce surgeon uncertainty regarding decision-making, we designed an Internet-enhanced multidisciplinary team (iMDT) working approach.
Methods: From August 2012 to April 2014, the iMDT discussed 215 patients with 266 metal-on-metal hip arthroplasties.
Background And Purpose: Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time.
View Article and Find Full Text PDF