Objectives: To compare the image quality and hepatic metastasis detection of low-dose deep learning image reconstruction (DLIR) with full-dose filtered back projection (FBP)/iterative reconstruction (IR).
Methods: A contrast-detail phantom consisting of low-contrast objects was scanned at five CT dose index levels (10, 6, 3, 2, and 1 mGy). A total of 154 participants with 305 hepatic lesions who underwent abdominal CT were enrolled in a prospective non-inferiority trial with a three-arm design based on phantom results.
Zero tillage (ZT) is widely promoted throughout India's Eastern Indo-Gangetic Plains (IGP) because of its potential to increase wheat productivity and resilience to abiotic stresses. Weeds remain a major barrier to ZT adoption, yet it remains unclear how ZT will influence weed communities in the Eastern-IGP. The primary objective of this study was to characterise the composition of the germinable weed seedbank sampled just prior to the wheat phase of rice-wheat farms in Bihar and Eastern Uttar Pradesh, and examine whether adoption of ZT wheat has shifted weed community composition compared to conventional tillage (CT).
View Article and Find Full Text PDFObjective: To assess the diagnostic performance and reader confidence in determining the resectability of pancreatic cancer at computed tomography (CT) using a new deep learning image reconstruction (DLIR) algorithm.
Methods: A retrospective review was conduct of on forty-seven patients with pathologically confirmed pancreatic cancers who underwent baseline multiphasic contrast-enhanced CT scan. Image data sets were reconstructed using filtered back projection (FBP), hybrid model-based adaptive statistical iterative reconstruction (ASiR-V) 60 %, and DLIR "TrueFidelity" at low(L), medium(M), and high strength levels(H).
Plant-microbe interactions in the rhizosphere influence rates of organic matter mineralization and nutrient cycling that are critical to sustainable agricultural productivity. Agricultural intensification, particularly the introduction of synthetic fertilizer in the USA, altered the abundance and dominant forms of nitrogen (N), a critical plant nutrient, potentially imposing selection pressure on plant traits and plant-microbe interactions regulating N cycling and acquisition. We hypothesized that maize adaptation to synthetic N fertilization altered root functional traits and rhizosphere microbial nutrient cycling, reducing maize ability to acquire N from organic sources.
View Article and Find Full Text PDFThe purpose of this study was to validate a novel approach to estimating effective dose (E) in 'fast-kV switch dual energy computed tomography' using MOSFET detectors. The effective energy of the combined dual energy environment was characterized with the dual energy CT scanner and then MOSFETs were calibrated matching to the effective energy of the dual energy CT beam with a conventional CT beam. The calibration method was then experimentally validated by comparing the dose between MOSFET and an ion chamber (IC) using a standard CTDI body phantom.
View Article and Find Full Text PDFRoots are notoriously difficult to study. Soil is both a visual and mechanical barrier, making it difficult to track roots in situ without destructive harvest or expensive equipment. We present a customizable and affordable rhizobox method that allows the non-destructive visualization of root growth over time and is particularly well-suited to studying root plasticity in response to localized resource patches.
View Article and Find Full Text PDFPatient-centric care has garnered the attention of the radiology community. The authors describe a patient-centric approach to iodinated contrast administration designed to optimize the diagnostic yield of contrast-enhanced CT while minimizing patient iodine load and exposure to ionizing radiation, thereby enhancing patient safety while providing reasonable diagnostic efficacy. Patient-centric CT hardware settings and contrast media administration are important considerations for clinical CT quality and safety.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2016
A novel method was presented for the effective dose (ED) measurement with metal-oxide-semiconductor field-effect transistor (MOSFET) detectors in dual-energy (DE) dual-source (DS) computed tomography (CT) scanner. This study demonstrated that the mean energy of the combined spectrum in dual-source computed tomography can be used to measure the ED. For validation, the MOSFET dose at the centre cavity of a CT dose index (CTDI) body phantom was compared with the dose measured with an energy-independent ion chamber (IC).
View Article and Find Full Text PDFThe purpose of this study was two-fold: (a) to measure the dose to the brain using clinical protocols at our institution, and (b) to develop a scanner-independent dosimetry method to estimate brain dose. Radiation dose was measured with a pediatric anthropomorphic phantom and MOSFET detectors. Six current neuroradiology protocols were used: brain, sinuses, facial bones, orbits, temporal bones, and craniofacial areas.
View Article and Find Full Text PDFObjective: The purpose of this study is to measure the organ doses and effective dose (ED) for parathyroid 4D CT and scintigraphy and to estimate the lifetime attributable risk of cancer incidence associated with imaging.
Materials And Methods: Organ radiation doses for 4D CT and scintigraphy were measured on the basis of imaging with our institution's protocols. An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was scanned to measure CT organ dose.
The purpose of this study was to validate a novel approach of applying a partial volume correction factor (PVCF) using a limited number of MOSFET detectors in the effective dose (E) calculation. The results of the proposed PVCF method were compared to the results from both the point dose (PD) method and a commercial CT dose estimation software (CT-Expo). To measure organ doses, an adult female anthropomorphic phantom was loaded with 20 MOSFET detectors and was scanned using the non-contrast and 2 phase contrast-enhanced parathyroid imaging protocols on a 64-slice multi-detector computed tomography scanner.
View Article and Find Full Text PDFPurpose: The aim of the study was to assess the image quality of multi-detector-row computed tomography (CT) angiographic images of the thoracic aorta reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) at different kVp and mA settings.
Methods: A healthy 56.1-kg Yorkshire pig underwent sequential arterial CT angiograms on a 64-slice multi-detector-row CT scanner (Discovery CT 750HD; GE Healthcare Inc, Milwaukee, Wis) at progressively lower kVp and mA settings.
The purpose of this study was three-fold: (1) to measure the transmission properties of various lead shielding materials, (2) to benchmark the accuracy of commercial film badge readings, and (3) to compare the accuracy of effective dose (ED) conversion factors (CF) of the U.S. Nuclear Regulatory Commission methods to the MOSFET method.
View Article and Find Full Text PDFObjective: The purpose of this study was to measure the organ doses and estimate the effective dose for the standard brain perfusion CT protocol and erroneous protocols.
Materials And Methods: An anthropomorphic phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. Protocol 1 used a standard brain perfusion protocol with 80 kVp and fixed tube current of 200 mA.
Objective: To compare the effective doses (EDs) associated with imaging modalities for follow-up of patients with urolithiasis, including stone protocol non-contrast computed tomography (NCCT), kidney, ureter, and bladder radiograph (KUB), intravenous urogram (IVU), and digital tomosynthesis (DT).
Methods: A validated Monte-Carlo simulation-based software PCXMC 2.0 (STUK) designed for estimation of patient dose from medical X-ray exposures was used to determine the ED for KUB, IVU (KUB scout plus three tomographic images), and DT (two scouts and one tomographic sweep).
Purpose: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.
View Article and Find Full Text PDFObjective: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT.
Materials And Methods: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose.
Objective: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding.
Materials And Methods: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield.
Objective: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT.
Materials And Methods: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp.
Objective: The purpose of this study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for routine CT of the brain.
Materials And Methods: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in the brain of a male anthropomorphic phantom scanned three times with a routine clinical brain CT protocol on four scanners from one manufacturer in four configurations and on one 64-MDCT scanner from another manufacturer. Absorbed organ doses were measured for skin, cranium, brain, lens of the eye, mandible, and thyroid.
Objective: The objective of our study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for common body CT studies.
Materials And Methods: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in a medium-sized anthropomorphic phantom of a man. Pulmonary embolism and chest, abdomen, and pelvis protocols were used to scan the phantom three times with GE Healthcare scanners in four configurations and one 64-MDCT Siemens Healthcare scanner.
Objective: The purpose of this study was to corroborate the relation between the estimated absorbed fetal dose derived from directly measured uterine doses early in the first trimester and the volume CT dose index (CTDI(vol)) for 16- and 64-MDCT of the maternal chest, abdomen, and pelvis.
Materials And Methods: Estimated absorbed fetal dose was measured with a metal oxide semiconductor field effect transistor (MOSFET) dosimeter placed in the expected uterine location in an anthropomorphic phantom of a woman and scanned with 16- and 64-MDCT units of one vendor and a 64-MDCT unit of another vendor. A trauma chest, abdomen, and pelvis protocol and an abdomen and pelvis protocol were used.
Objective: The purpose of this study was to assess whether radiation dose savings using a lower peak kilovoltage (kVp) setting, bismuth breast shields, and automatic tube current modulation could be achieved while preserving the image quality of MDCT scans obtained to assess for pulmonary embolus (PE).
Materials And Methods: CT angiography (CTA) examinations were performed to assess for the presence or absence of pulmonary artery emboli using a 64-MDCT scanner with automatic tube current modulation (noise level=10 HU), two kVp settings (120 and 140 kVp), and bismuth breast shields. Absorbed organ doses were measured using anthropomorphic phantoms and metal oxide semiconductor field effect transistor (MOSFET) detectors.