Study Design: Retrospective cohort study.
Objective: Screw loosening in spinal fusion is poorly defined. Accordingly, its prevalence rates range from 1% to 60%, and its risk factors remain undefined.
Background: Arterial injury secondary to acute knee dislocation (KD) is a rare but devastative complication. The aim of this study is to evaluate functional sequelae and factors of poor prognosis.
Methods: A retrospective monocentric series of consecutive KD with acute ischemia by popliteal artery injury was analyzed between 2005 and 2017.
BMC Med Res Methodol
January 2018
Background: This article corresponds to a literature review and analyze how heterogeneity of treatment (HTE) is reported and addressed in cohort studies and to evaluate the use of the different measures to HTE analysis.
Methods: prospective cohort studies, in English language, measuring the effect of a treatment (pharmacological, interventional, or other) published among 119 core clinical journals (defined by the National Library of Medicine) in the last 16 years were selected in the following data source: Medline. One reviewer randomly sampled journal articles with 1: 1 stratification by journal type: high impact journals (the New England Journal of Medicine, JAMA, LANCET, Annals of Internal Medicine, BMJ and Plos Medicine) and low impact journal (the remaining journals) to identify 150 eligible studies.
Purpose: Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE).
View Article and Find Full Text PDFPurpose: Recently introduced cobalt-chromium (CoCr) rods that rely solely on pedicle screws produce very good results in correcting scoliotic curves. All-pedicle screws constructs are also suspected of decreasing thoracic kyphosis. The current study was designed to evaluate sagittal correction in adolescent idiopathic scoliosis patients, using 6-mm CoCr rods and all-screw constructs.
View Article and Find Full Text PDFOBJECTIVE Adjacent-segment disease (ASD) is an increasingly problematic complication following lumbar fusion surgery. The purpose of the current study was to determine the risk of ASD requiring surgical treatment after short lumbar or lumbosacral fusion. Primary spinal disease and surgical factors associated with an increased risk of revision were also investigated.
View Article and Find Full Text PDFPurpose: Hip fusion conversion has shown mixed results, in particular a higher rate of failure than primary total hip replacement. Conversion is usually carried out by a lateral approach.
Methods: We reported a series of 37 hip fusion conversions performed by an anterior approach.
Background: Charnley low-friction torque total hip arthroplasty (THA) remains the gold standard in THA. The main cause for failure is wear of the socket. Highly crosslinked polyethylene (HXLPE) has been associated with reduced wear rates.
View Article and Find Full Text PDFAlthough cemented all polyethylene (PE) cups have been routinely used in total hip arthroplasty for decades, no computer-assisted method for measurement of radiographic wear has ever been specifically validated for these implants. Using a validated hip phantom model, AP plain hip radiographs were obtained consecutively for eight simulated wear positions. A version of Martell's Hip Analysis Suite software dedicated to all polyethylene sockets was used by three different examiners of varied experience.
View Article and Find Full Text PDFPurpose: Highly cross-linked polyethylenes (PE) have been developed with encouraging results in terms of wear. Another body of the literature has indicated potential catastrophic failures related to reduced fatigue properties and oxidation. Each PE available on the market has its own processing characteristics.
View Article and Find Full Text PDFPurpose: The purpose of this study was to identify the shortest possible length of an established cemented hip stem in order to reduce stress shielding and optimise its bending behaviour.
Methods: Twenty-five prototypes from the same batch (five for each stem length) were included. Lengths resulted from the original length (100 %) and four distal shortenings to 94, 88, 83 and 78 % of original length.
Purpose: The aim of this study was to evaluate the osseointegration of a new coating directly deposited on PE at room temperature.
Methods: Thirty-six (36) male New Zealand rabbits were randomly assigned to receive one out of three types of implants: two tested implants, i.e.