Publications by authors named "Carmen T Brindeiro"

Background: The relative importance of different ultraviolet-C (UV-C) emitter configurations on the attenuation of vegetative bacterial and fungal pathogens has not been assessed. We hypothesized that emitter configuration would impact the efficacy of UV-C attenuation of and ( pathogens.

Methods: American Type Culture Collection (ATCC) (ATCC 6538) and (ATCC MYA-5001 carriers (ReadyNowTM Test Carriers, Stratix Labs Corporation, Saint Paul, MN) were mounted on an aluminum stand along with three calibrated radiometers (International Light Technologies model ILT1270, Peabody, MA).

View Article and Find Full Text PDF

Background: The impact of ultraviolet-C (UV-C) emitter configuration on pathogen attenuation has not been assessed. We hypothesized that emitter configuration would impact UV-C efficacy for () attenuation.

Methods:  carriers (ReadyNow Test Carriers, Stratix Labs Corporation, Saint Paul, MN) inoculated with > 10 American Type Culture Collection (ATCC) 43593 (according to American Society for Testing and Materials (ASTM) 3135 standards) were obtained, and the following experiments were conducted from April to August of 2023.

View Article and Find Full Text PDF

Background: We hypothesized that ultraviolet-C (UV-C) irradiation (Surfacide, Waukesha, WI) following use of microfiber cloths (Sanny Shop LLC, Longmont, CO) soaked in water would be noninferior to surface disinfection wipes containing a quaternary ammonium compound and alcohol (PDI Healthcare, Woodcliff Lake, NJ) for the pathogenic () sequence type 5 (ST5).

Methods: This was a randomized laboratory study of disinfection approaches for  ST5. A total of 270 polycarbonate slides loaded with ST5 were prepared for the standard surface disinfection group (N=18) and water-soaked microfiber cloths and UV-C treatment group (N=144), along with positive and negative microbiological controls.

View Article and Find Full Text PDF

Purpose: Preventing the spread of pathogens in the anesthesia work area reduces surgical site infections. Improved cleaning reduces the percentage of anesthesia machine samples with ≥ 100 colony-forming units (CFU) per surface area sampled. Targeting a threshold of < 100 CFU when cleaning anesthesia machines may be associated with a lower prevalence of bacterial pathogens.

View Article and Find Full Text PDF