The analysis of pesticide residues and mycotoxins in baby food demands exceptionally low limits of quantitation, necessitating the use of highly sensitive instruments capable of conducting trace analyses. High-resolution instruments typically fail to detect such low levels. However, the latest advancements in liquid time-of-flight technology, when coupled with ion trapping, enable ion enrichment, thereby improving detection levels.
View Article and Find Full Text PDFIn this comprehensive study, we evaluated the feasibility of using hydrogen instead of helium as a carrier gas in a GC-MS/MS system for pesticide residue analysis, spanning three matrices: pepper, tomato, and zucchini. Initial assessments focused on the ion source's chemical inertness, employing nitrobenzene as a benchmark to monitor the hydrogenation process. A method with a duration of less than 12 minutes was developed, achieving good chromatographic peak resolution attributable to the enhanced chromatographic performance of hydrogen as a carrier gas.
View Article and Find Full Text PDFClean-up step is essential during the multiresidue sample preparation process to remove undesired matrix components that may cause analytical interferences or suppression effect. However, its application generally by specific sorbents entails time-consuming work producing low recoveries for some compounds. Moreover, it usually needs to be adapted to the different co-extractives from the matrix present in the samples by using different chemical sorbents increasing the number of validation procedures.
View Article and Find Full Text PDFBackground And Objective: The objective was to describe the clinical characteristics and prognosis of patients with nosocomial SARS-CoV-2 infection.
Methods: An observational and prospective study was performed in a referral hospital. We included all adult patients diagnosed with nosocomial SARS-CoV-2 infection in October 2020.
A fast and sensitive method was validated for the analysis of pesticide residues in baby food. After an QuEChERS-based extraction, the samples were analysed with a dual-channel liquid chromatography instrument coupled to a triple quadrupole mass spectrometer. The method consisted of two independent injections per sample.
View Article and Find Full Text PDFBackground And Objective: The objective was to describe the clinical characteristics and prognosis of patients with nosocomial SARS-CoV-2 infection.
Methods: An observational and prospective study was performed in a referral hospital. We included all adult patients diagnosed with nosocomial SARS-CoV-2 infection in October 2020.
Abundant studies have been published evaluating different parameters of reverse-phase liquid chromatography (LC) and supercritical fluid chromatography (SFC), both coupled to electrospray (ESI)/mass spectrometry (MS) for pesticide residue analysis. However, there is a lack of a comprehensive comparative study that facilitates deep knowledge about the benefits of using each technique. In the present study, the same mass spectrometer was used coupled to both liquid and supercritical fluid chromatographies with a multiresidue method of 215 compounds, for the analysis of pesticide residues in food samples.
View Article and Find Full Text PDFTalanta
June 2021
The use of high-resolution mass spectrometry (HRMS) for the simultaneous target and non-target analysis of pesticide residues in food control is a subject that has been studied over the last decade. However, proving its efficacy compared to the more established triple quadrupole mass spectrometers (QQQ-MS2) is challenging. Various HRMS platforms have been evaluated, seemingly showing this approach not to be as effective as QQQ-MS2 for quantitative analysis, especially in routine food testing laboratories.
View Article and Find Full Text PDFAnthraquinone has been linked to potential adverse effects on human health and the environment. The most commonly employed methods for the analysis of coffee and tea cause the extraction of matrix interferents such as the methylxanthines caffeine and theobromine, which hinder the analysis of anthraquinone. A new manual extraction method - using ethyl acetate as the extraction solvent with a dispersive solid-phase extraction clean-up step based on primary-secondary amines - has been developed.
View Article and Find Full Text PDFSerious difficulties in evaluating the fungicides captan and folpet by the usual chromatography systems coupled to mass spectrometry are well known. These compounds are highly prone to degradation due to different conditions into tetrahydrophthalimide (THPI) and phthalimide (PHI). Such an effect can be produced at different stages of the analytical procedure or during the growing crop, making their evaluation troublesome.
View Article and Find Full Text PDFEvaluation of chiral pesticides remains a frequently neglected matter in routine food control laboratories. This fact is due to the existence of many residue definitions but also due to the lack of robust instrumental methods for the evaluation of these isomeric compounds. However, supercritical fluid chromatography coupled to mass spectrometry (SFC-ESI-MS/MS) has been demonstrated to perform fast and highly efficient separations without the need to change the mobile phase employed in multiresidue pesticide analyses.
View Article and Find Full Text PDFIn the last decade, the consumption trend of organic food has increased dramatically worldwide. Since only a few pesticides are authorized in organic crops, concentrations are expected to range at zero or ultra-trace levels. In this context, the aim of the present study was to investigate the need for an improvement in the residue controls at very low concentrations (<0.
View Article and Find Full Text PDFThe introduction of sequential mass isolation window acquisition mode in high-resolution quadrupole time-of-flight analysers undoubtedly represents an important improvement in the MS/MS spectra obtained when working in non-target analysis. However, the advantages and limitations of this approach have not been sufficiently defined and evaluated. The present work seeks to fill this gap by considering its application in non-target multiresidue pesticide analysis.
View Article and Find Full Text PDFThermally labile pesticides (captafol, captan, dicofol, and folpet) are highly prone to suffer thermal degradation during sample introduction into a gas chromatograph (GC) to tetrahydrophthalimide (THPI), 4,4'-dichlorobenzophenone (DCBP), and phthalimide (PI), respectively, mainly produced in the glass liner of the injector. This undesired behavior leads to inaccurate qualitative and quantitative results. Direct on-column injection (OCI) technique is evaluated as an alternative to avoid or minimize compound alteration during the analysis.
View Article and Find Full Text PDFThe aim of the study is to evaluate demographics, epidemiology, clinical characteristics, treatment and outcomes of Clostridium difficile infection (CDI) in patients with and without concurrent cancer. This is a prospective cohort study of consecutive primary CDI episodes in adults (January 2006-December 2016). CDI was diagnosed on the presence of diarrhoea and positive stool testing for toxigenic C.
View Article and Find Full Text PDFAnaerobe
June 2018
Objective: Describe secular trends in the epidemiology and outcome of Clostridium difficile infection (CDI) at a tertiary hospital.
Methods: All consecutive primary CDI episodes in adults (January 2006-December 2015) were included. CDI was diagnosed on the presence of diarrhoea and a positive stool test for C.
This paper presents an efficiency evaluation of GC coupled with quadrupole Orbitrap MS for identification and quantitation in the multiresidue pesticide analysis of baby foods in full-scan mode. The identification criteria were studied following SANTE guidelines (retention time, mass accuracy, and ion ratio), comfortably complying with the values established, even at 0.003 mg/kg.
View Article and Find Full Text PDFAim: We aimed to explore the meaning of obesity in elderly persons with knee osteoarthritis (KO) and to determine the factors that encourage or discourage weight loss.
Background: Various studies have demonstrated that body mass index is related to KO and that weight loss improves symptoms and functional capacity. However, dietary habits are difficult to modify and most education programs are ineffective.
The use of yttria-stabilized zirconium dioxide nanoparticles as d-SPE clean-up sorbent for a rapid and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the determination of post-harvest fungicides (carbaryl, carbendazim, chlorpropham, diphenylamine, ethoxyquin, flutriafol, imazalil, iprodione, methomyl, myclobutanil, pirimiphos-methyl, prochloraz, pyrimethanil, thiabendazole, thiophanate-methyl and tolclofos-methyl) in orange and pear samples has been evaluated and validated. The sample preparation was a modification of the QuEChERS extraction method using yttria-stabilized zirconium dioxide and multi-walled carbon nanotubes (MWCNTs) nanoparticles as the solid phase extraction (d-SPE) clean-up sorbents prior to injecting the ten-fold diluted extracts into the LC system. By using the yttria-stabilized zirconium dioxide extraction method, more recoveries in the 70-120% range were obtained - thus this method was used for the validation.
View Article and Find Full Text PDFVenous catheter-related infections are a problem of particular importance, due to their frequency, morbidity and mortality, and because they are potentially preventable clinical processes. At present, the majority of hospitalized patients and a considerable number of outpatients are carriers of these devices. There has been a remarkable growth of knowledge of the epidemiology of these infections, the most appropriate methodology for diagnosis, the therapeutic and, in particular, the preventive strategies.
View Article and Find Full Text PDFRapid Commun Mass Spectrom
November 2013
Rationale: Dendrimer nanocarriers have become of increasing interest in the field of biomedicine for their drug delivery potential. Surface modifications and optimized nanosize control are the strategies being followed to enhance drug delivery efficacy and renal clearance, especially for dendrimers of a lower generation number. The aim of this study was the development and performance evaluation of an analytical method for the quantitative determination of polyamidoamine (PAMAM) dendrimers in urine.
View Article and Find Full Text PDFSeveral extraction methods were evaluated in terms of recoveries and extraction precision for 113 pesticides in avocado: QuEChERS with various d-SPE clean-ups (Z-Sep, Z-Sep+, PSA+C18 and silica), miniLuke and ethyl acetate. Extracts were analysed using liquid chromatography coupled with triple quadrupole mass spectrometer working in multi-reaction monitoring mode. Z-Sep and Z-Sep+ are new types of material for high lipid matrices - these two sorbents contain ZrO2, which improves fat removal from the extracts.
View Article and Find Full Text PDFDuring recent years matrix effects in liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) have quickly become a major concern in food analysis. The phenomenon of ion suppression can lead to errors in the quantification of the analytes of interest, as well as can affect detection capability, precision, and accuracy of the method. Sample dilution is an easy and effective method to reduce interfering compounds, and so, to diminish matrix effects.
View Article and Find Full Text PDFThe aim of this work was to study the effect of olive powder combined with high hydrostatic pressure (HHP) on the inactivation of Bacillus cereus spores, to use it as an additional control hurdle in beverages pasteurised by this technology. With this purpose, reference medium prepared at different concentrations of olive powder was inoculated with B. cereus spores and subjected to different pressure treatments.
View Article and Find Full Text PDF