The purpose of this study was to compare the dosimetry of CG-Darc with three-dimensional conformal radiation therapy (3D CRT) and volumetric-modulated arc therapy (RapidArc) in the treatment of breast cancer with APBI. CG-Darc plans were generated using two tangential couch arcs combined with a simultaneous noncoplanar gantry arc. The dynamic couch arc was modeled by consecutive IMRT fields at 10° intervals.

View Article and Find Full Text PDF

Purpose: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes.

View Article and Find Full Text PDF

Purpose: When treatment intent is to include breast and internal mammary lymph nodes (IMNs) in the clinical target volume (CTV), a significant volume of the heart may receive radiation, which may result in late morbidity. The value of conformal intensity-modulated radiation therapy (IMRT) to avoid heart dose was studied.

Methods And Materials: Breast, IMNs, and normal tissues were contoured for 30 consecutive patients previously treated with RT after lumpectomy for left-sided breast cancer.

View Article and Find Full Text PDF

The purpose of this study was to determine the optimum beam number and orientation for inverse-planned, dynamic intensity-modulated radiation therapy (IMRT) for treatment of left-sided breast cancer and internal mammary nodes (IMNs) to improve target coverage while reducing cardiac and ipsilateral lung irradiation. Computed tomography (CT) data was used from 5 patients with left-sided breast cancer in whom the heart was close to the chest wall. The planning target volume (PTV) was the full breast plus ipsilateral IMNs.

View Article and Find Full Text PDF

Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility.

View Article and Find Full Text PDF