Tremendous breakthroughs are being made in cancer drug discovery and development. However, such breakthroughs come at a high financial cost. At a time when there is increasing pressure on drug pricing, in part because of increased life expectancy, it is more important than ever to drive new therapeutics towards patients as efficiently as possible.
View Article and Find Full Text PDFA new generation of monomolecular imaging probes (MOMIP) based on a distyryl-BODIPY (BODIPY=boron-dipyrromethene) coupled with three DOTA macrocycles has been prepared (DOTA=1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid). The MOMIP presents good fluorescence properties and is very stable in serum. The bimodal probe was conjugated to trastuzumab, and an optical in vivo study showed high accumulation of the imaging agent at the tumor site.
View Article and Find Full Text PDFUnlabelled: AKT (a serine/threonine-specific protein kinase) regulates many cellular processes contributing to cytotoxic drug resistance. This study's primary objective examined the relationship between GSK2141795, an oral, pan-AKT inhibitor, and (18)F-FDG PET markers of glucose metabolism in tumor tissue to determine whether (18)F-FDG PET could be used to guide personalized dosing of GSK2141795. Biomarker analysis of biopsies was also undertaken.
View Article and Find Full Text PDFSince twenty years, many nanoparticles based on high atomic number elements have been developed as radiosensitizers. The design of these nanoparticles is limited by the classical rules associated with the development of nanoparticles for oncology and by the specific ones associated to radiosensitizers, which aim to increase the effect of the dose in the tumor area and to spare the health tissues. For this application, systemic administration of nanodrugs is possible.
View Article and Find Full Text PDFBackground: The recent introduction of biological anticancer therapy has renewed the interest in functional imaging of tumor-associated angiogenesis (TAA) as a tool to monitor early therapy response. The present study evaluated imaging of TAA using P1227, a novel, small molecular magnetic resonance imaging (MRI) probe targeting αvβ3 integrin.
Methods: HT29 human colorectal cancers were grown in athymic mice.
Aim: The main objective of the survey was to determine the frequency of the mono and polysensitizations in patients consulting for respiratory allergy, rhinitis or/and asthma. The secondary objectives were to evaluate the severity, the number and the type of the sensitizations, the frequency of the asthma or rhinitis as a function of the sensitizations, the evolution of the sensitizations with age, and identify the principal responsible pneumallergens.
Patients And Methods: The multicentric survey included a patient questionnaire allowing the collection and anonymous treatment of data on socio-demographic characteristics, clinical symptoms, cutaneous tests and sensitizations.
Objectives: To investigate whether a magnetic resonance (MR) blood pool contrast agent enables both evaluation of myocardial perfusion and viability in nonreperfused infarction in pigs.
Materials And Methods: An optimized MR protocol using the blood pool contrast agent P792 (0.026 mmol/kg, twice the clinical dose, Guerbet, France) was investigated to evaluate nonreperfused myocardial infarction in an animal model.
In the present study we investigated the effects of water exchange between intra- and extravascular compartments on absolute quantification of regional myocardial blood flow (rMBF) using a saturation-recovery sequence with a rather long inversion time (TI, 176 ms) and a T1-shortening intravascular contrast agent (CMD-A2-Gd-DOTA). Data were acquired in normal and ischemically injured pigs, with radiolabeled microsphere flow measurements used as the gold standard. Five water exchange rates (fast, 6 Hz, 3 Hz, 1 Hz, and no exchange) were tested.
View Article and Find Full Text PDFAim: : We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach in an animal model under acquisition conditions as close as possible to clinical reality.
View Article and Find Full Text PDFMagnetic resonance imaging is a popular and powerful non-invasive imaging technique. Automated analysis has become mandatory to efficiently cope with the large amount of data generated using this modality. However, several artifacts, such as intensity non-uniformity, can degrade the quality of acquired data.
View Article and Find Full Text PDF