Publications by authors named "Carlos R Grandini"

Prosthetic joint infections (PJIs) remain a significant challenge, occurring in 1% to 2% of joint arthroplasties and potentially leading to a 20% to 30% mortality rate within 5 years. The primary pathogens responsible for PJIs include Staphylococcus aureus, coagulase-negative staphylococci, and Gram-negative bacteria, typically treated with intravenous antibiotic drugs. However, this conventional approach fails to effectively eradicate biofilms or the microbial burden in affected tissues.

View Article and Find Full Text PDF

The design of particle size and morphology are a promising approach to investigating the properties exhibited by different types of materials. In the present study, the silver phosphate microcrystals (AgPO) were first time synthesized using the hydrothermal and solvothermal method by combination of the solvents water/isopropyl alcohol (SP-IA), water/acetone (SP-AC), water/ammonium hydroxide (AP-AH), all in a ratio of 1:1 (v/v). The synthesized materials were structurally characterized by X-ray diffraction (XRD), Rietveld refinement, and Raman vibrational spectroscopy, where it was confirmed that the pure phase was achieved for all prepared samples.

View Article and Find Full Text PDF

β-type titanium alloys with a body-centered cubic structure are highly useful in orthopedics due to their low elastic modulus, lower than other commonly used alloys such as stainless steel and Co-Cr alloys. The formation of the β phase in titanium alloys is achieved through β-stabilizing elements such as Nb, Mo, and Ta. To produce new β alloys with a low modulus of elasticity, this work aimed to produce our alloy system for biomedical applications (Ti-50Nb-Mo).

View Article and Find Full Text PDF

Among the different surface modification techniques, micro-arc oxidation (MAO) is explored for its ability to enhance the surface properties of Ti alloys by creating a controlled and durable oxide layer. The incorporation of Cu ions during the MAO process introduces additional functionalities to the surface, offering improved corrosion resistance and antimicrobial activity. In this study, the β-metastable Ti-30Nb-5Mo alloy was oxidated through the MAO method to create a Cu-doped TiO coating.

View Article and Find Full Text PDF

This study aimed to produce Ti-15Nb alloy with a low elastic modulus, verify its biocompatibility, and determine whether the alloy indirectly influences cellular viability and morphology, as well as the development of the osteogenic phenotype in cells cultured for 2, 3, and 7 days derived from rat calvarias. Two heat treatments were performed to modify the mechanical properties of the alloy where the Ti-15Nb alloy was heated to 1000 °C followed by slow (-5 °C/min) (SC) and rapid cooling (RC). The results of structural and microstructural characterization (XRD and optical images) showed that the Ti-15Nb alloy was of the α + β type, with slow cooling promoting the formation of the α phase and rapid cooling the formation of the β phase, altering the values for the hardness and elastic modulus.

View Article and Find Full Text PDF

The technique of surface modification using electrolytic oxidation, called micro-arc oxidation (MAO), has been used in altering the surface properties of titanium alloys for biomedical purposes, enhancing their characteristics as an implant (biocompatibility, corrosion, and wear resistance). The layer formed by the micro-arc oxidation process induces the formation of ceramic oxides, which can improve the corrosion resistance of titanium alloys from the elements in the substrate, enabling the incorporation of bioactive components such as calcium, phosphorus, and magnesium. This study aims to modify the surfaces of Ti-25Ta-10Zr-15Nb (TTZN1) and Ti-25Ta-20Zr-30Nb (TTZN2) alloys via micro-arc oxidation incorporating Ca, P, and Mg elements.

View Article and Find Full Text PDF

It is crucial for clinical needs to develop novel titanium alloys feasible for long-term use as orthopedic and dental prostheses to prevent adverse implications and further expensive procedures. The primary purpose of this research was to investigate the corrosion and tribocorrosion behavior in the phosphate buffered saline (PBS) of two recently developed titanium alloys, Ti-15Zr and Ti-15Zr-5Mo (wt.%) and compare them with the commercially pure titanium grade 4 (CP-Ti G4).

View Article and Find Full Text PDF

Ti and its alloys are the most used metallic biomaterials devices due to their excellent combination of chemical and mechanical properties, biocompatibility, and non-toxicity to the human body. However, the current alloys available still have several issues, such as cytotoxicity of Al and V and high elastic modulus values, compared to human bone. β-type alloys, compared to α-type and (α + β)-type Ti alloys, have lower elastic modulus and higher mechanical strength.

View Article and Find Full Text PDF

There are several treatment methods available for bone repair, although the effectiveness becomes limited in cases of large defects. The objective of this pre-clinical protocol was to evaluate the grafting of hydroxyapatite/tricalcium phosphate (BCP) ceramic biomaterial (B; QualyBone BCP, QualyLive, Amadora, Portugal) together with the heterologous fibrin biopolymer (FB; CEVAP/UNESP Botucatu, Brazil) and with photobiomodulation (PBM; Laserpulse, Ibramed, Amparo, Brazil) in the repair process of bone defects. Fifty-six rats were randomly divided into four groups of seven animals each: the biomaterial group (G1/B), the biomaterial plus FB group (G2/BFB); the biomaterial plus PBM group (G3/B + PBM), and the biomaterial plus FB plus PBM group (G4/BFB + PBM).

View Article and Find Full Text PDF

The use of dental implants is growing rapidly for the last few decades and Ti-based dental implants are a commonly used prosthetic structure in dentistry. Recently, the combined effect of corrosion and wear, called tribocorrosion, is considered as a major driving process in the early failure of dental implants. However, no previous study has reported the prediction of tribocorrosion processes in advance.

View Article and Find Full Text PDF

In this study, hybrid composites based on β-alloy Ti-Nb and oxide nanotubes (NTs) have been successfully prepared. NTs of different sizes were grown on Ti-Nb substrates with different Nb contents (5, 25, and 50 wt %) via electrochemical anodization at 30 and 60 V. Scanning electron microscopy imaging revealed that vertically aligned nanotubular structures form on the surface of Ti-Nb alloy substrates and influence Nb content in alloys based on NT length.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate the response of osteogenic cell lineage and gingival fibroblastic cells to different surface treatments of grade IV commercially pure Titanium (cpTi) disks.

Material And Methods: Grade IV cpTi disks with different surfaces were produced: machined (M), sandblasting (B), sandblasting and acid subtraction (NP), and hydrophilic treatment (ACQ). Surface microtopography characteristics and chemical composition were investigated by scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDS).

View Article and Find Full Text PDF

Due to excellent biocompatibility and corrosion resistance, the application of titanium alloys in orthopedic and dental implants has been increasing since the 1970s. However, the elasticity of these alloys as measured by their Young's modulus is still about two to four times higher than that of human cortical bone. The most widely used titanium alloy for biomedical applications is Ti-6Al-4V, however, previous studies have shown that the vanadium used in this alloy causes allergic reactions in human tissue and aluminum, also used in the alloy, has been associated with neurological disorders.

View Article and Find Full Text PDF

Titanium alloys have been widely used as biomaterials, especially for orthopedic prostheses and dental implants, but these materials have Young's modulus almost three times greater than human cortical bones. Because of this, new alloys are being produced for the propose of decreasing Young's modulus to achieve a more balanced mechanical compatibility with the bone. In this paper, it is reported the development of Ti-25Ta alloys as a base material, in which was introduced zirconium, with concentration varying between 0 and 40 wt%, with the aim of biomedical applications.

View Article and Find Full Text PDF

Titanium alloys are widely used in the biomedical field due to their excellent resistance to corrosion, high mechanical strength/density ratio, low elastic modulus, and good biocompatibility. Niobium is a β-stabilizer element that has the potential to decrease elastic modulus and possesses excellent corrosion resistance. In this article, Ti-15Nb alloy was prepared via arc-melting, with the aim of using it in biomedical applications to replace implants that fail due to mechanical incompatibility with human bone.

View Article and Find Full Text PDF

Titanium and its alloys currently are used as implants, possessing excellent mechanical properties (more suited than stainless steel and Co-Cr alloys), good corrosion resistance and good biocompatibility. The titanium alloy used for most biomedical applications is Ti-6Al-4V, however, studies showed that vanadium and aluminum cause allergic reactions in human tissues and neurological disorders. New titanium alloys without the presence of these elements are being studied.

View Article and Find Full Text PDF

Materials and surfaces developed for dental implants need to withstand degradation processes that take place in the oral cavity. Therefore, the aim of the study was to develop and evaluate the topographical, mechanical, chemical, electrochemical and biological properties of Ti-xZr alloys (x = 5, 10, and 15 wt%) with two surface features (machined and double acid etched). Commercially pure titanium (cpTi) and Ti-6Al-4V alloy were used as controls.

View Article and Find Full Text PDF

Introduction: High levels of shrinkage stress caused by volumetric variations during the activation process are one of the main problems in the practical application of composite resins.

Objective: The aim of this study is to reduce the shrinkage stress and minimize the effects caused by composite resin volumetric variation due to the photopolymerization. In this way, this work proposes a systematic study to determine the optimal dimming function to be applied to light curing processes.

View Article and Find Full Text PDF

Objective: The aim of this study was to develop binary and ternary titanium (Ti) alloys containing zirconium (Zr) and niobium (Nb) and to characterize them in terms of microstructural, mechanical, chemical, electrochemical, and biological properties.

Methods: The experimental alloys - (in wt%) Ti-5Zr, Ti-10Zr, Ti-35Nb-5Zr, and Ti-35Nb-10Zr - were fabricated from pure metals. Commercially pure titanium (cpTi) and Ti-6Al-4V were used as controls.

View Article and Find Full Text PDF

Titanium has an allotropic transformation around 883°C. Below this temperature, the crystalline structure is hexagonal close-packed (α phase), changing to body-centered cubic (β phase). Zirconium has the same allotropic transformation around 862°C.

View Article and Find Full Text PDF

Cp-Ti is the most common material used for dental implants, but its elastic modulus is around five times higher than that of bone. Recently, promising alloys that add Nb, Ta, Zr and Mo to Ti have been developed. The mechanical properties of these alloys are directly related to its microstructure and the presence of interstitial elements, such as oxygen, carbon, nitrogen and hydrogen.

View Article and Find Full Text PDF

The mechanical properties of Ti alloys are changed significantly with the addition of interstitial elements, such as oxygen. Because oxygen is a strong stabilizer of the α phase and has an effect on hardening in a solid solution, it has aroused great interest in the biomedical area. In this paper, Ti-Zr alloys were subjected to a doping process with small amounts of oxygen.

View Article and Find Full Text PDF

The Ti-15Mo alloy has its mechanical properties strongly altered by heat treatments and by addition of interstitial elements, such as, oxygen, for example. In this sense, the objective of this paper is to analyze the effect of the introduction of oxygen in selected mechanical properties and the biocompatibility of Ti-15Mo alloy. The samples used in this study were prepared by arc-melting and characterized by density measurements, X-ray diffraction, scanning electron microscopy, microhardness, modulus of elasticity, and biocompatibility tests.

View Article and Find Full Text PDF

The most commonly used titanium (Ti)-based alloy for biological applications is Ti-6Al-4V, but some studies associate the vanadium (V) with the cytotoxic effects and adverse reactions in tissues, while aluminum (Al) has been associated with neurological disorders. Ti-Nb alloys belong to a new class of Ti-based alloys with no presence of Al and V and with elasticity modulus values that are very attractive for use as a biomaterial. It is well known that the presence of interstitial elements (such as oxygen, for example) changes the mechanical properties of alloys significantly, particularly the elastic properties, the same way that heat treatments can change the microstructure of these alloys.

View Article and Find Full Text PDF

Objective: This study evaluated the glass transition temperature (Tg) and degree of conversion (DC) of a light-cured (Fill Magic) versus a chemically cured (Concise) orthodontic composite.

Material And Methods: Anelastic relaxation spectroscopy was used for the first time to determine the Tg of a dental composite, while the DC was evaluated by infrared spectroscopy. The light-cured composite specimens were irradiated with a commercial LED light-curing unit using different exposure times (40, 90 and 120 s).

View Article and Find Full Text PDF