This case report features a female patient with the chief complaint of needing to replace an anterior crown. After a comprehensive oral assessment and cone beam computed tomography (CBCT) radiographic examination, it was determined that the crown on Tooth #9 was subgingivally fractured. The procedure involved atraumatic extraction of Tooth #9, followed by immediate implant placement.
View Article and Find Full Text PDFRestorative dentistry often uses ceramic laminate veneers for aesthetic anterior teeth restorations due to their natural appearance and minimal invasiveness. However, the understanding of their clinical performance and how ceramic microstructure and processing affect longevity is limited. This study aimed to address this gap by determining the mechanical behavior, fracture load, and failure modes of CAD-CAM processed laminate veneers made of either lithium-disilicate-based glass ceramic (IPS e.
View Article and Find Full Text PDFBackground: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging.
Methods: Disk-shaped specimens (Ø10 × 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow, Venus Bulk-Fill Flow, and Estelite Bulk-Fill Flow). The specimens in each bulk-fill resin composite group were divided into two subgroups (n = 10 per subgroup) with two different shades, A1 (N = 30) and A3 (N = 30), and were polymerized with light curing (800 mW/cm/Valo LED Unit, Ultradent) and polished.
The incorporation of silver nanoparticles (AgNPs) into alginate-gelatin (Alg-Gel) hydrogels can enhance the properties of these materials for bone regeneration applications, due to the antimicrobial properties of AgNPs and non-cytotoxic concentrations, osteoinductive properties, and regulation of stem cell proliferation and differentiation. Here, the hydrogel formulation included 2% (/) sodium alginate, 4 µg/mL AgNPs, and 2.5% (/) gelatin.
View Article and Find Full Text PDFThe esthetics of immediate implant dentistry can be challenging. Clinical considerations for immediate implant placement have demonstrated long-term success rates comparable to traditional delayed implant protocols. However, it is a sensitive technique that requires proper treatment planning as well as meticulous execution to be predictable and successful in the long term.
View Article and Find Full Text PDFPostoperative pain is a common concern following root canal treatments (RCT), impacting both patients and oral health practitioners. This systematic review and meta-analysis aimed to evaluate the effectiveness of laser treatment modalities in reducing postoperative pain compared to conventional methods after primary and secondary RCT in permanent mature teeth. A search of three electronic databases (PubMed, ScienceDirect, and The Cochrane Library) was conducted, using a broad range of keywords and terms.
View Article and Find Full Text PDFThis case report presents the conservative management of a malposed implant in the maxillary anterior region caused by craniofacial bone remodeling. The patient expressed dissatisfaction with the position and shade of an implant that was placed almost three decades previously. After evaluating different treatment options, the patient opted to replace the implant prosthesis.
View Article and Find Full Text PDFAim: Current CAD/CAM techniques allow clinicians to design and 3D print tooth reduction guides that facilitate controlled preparations in the esthetic zone. The present case report describes the workflow for designing and printing a tooth reduction guide intended to assist ceramic veneer preparations. This 3D-printed guide divides the facial surface of the teeth into four areas and allows the measuring of all areas, including the incisal edge, with a periodontal probe.
View Article and Find Full Text PDFDesign: A single-center (university-setting), prospective, longitudinal, split-mouth, single-blind, randomized controlled clinical trial investigated peri-implant parameters of bone-level implants restored with either screw-retained prostheses connected directly to the implants or with intermediate abutments over a 3-year period. The study adhered to the ethical principles of the Helsinki Declaration and the CONSORT guidelines. Ethical approval was granted, and the trial was registered at Clinicaltrials.
View Article and Find Full Text PDFPurpose: This study investigated the fracture resistance and failure modes of custom-fabricated post- and core dental restorations using various CAD/CAM materials.
Materials And Methods: Seventy-five mandibular second premolars were allocated to five groups (n = 15) and prepared for standardized post and core restorations. The groups included a control group comprising cast metal and four CAD/CAM materials: Vita Enamic, Shofu HC, Trilor, and PEKK.
Computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry have significantly changed workflows in recent years. Restorations and devices can now be digitally designed and 3D-printed for dental care purposes. This clinical case report provides straightforward protocols for the digital design and 3D manufacture of gingivectomy and tooth preparation guides.
View Article and Find Full Text PDFBackground In light of the trend of using zirconia crowns, clinicians will likely face abutment included in removable partial dentures (RPD) designs with existing zirconia. However, the decision to replace the existing crown with a surveyed crown or modify the existing crown to accept the RPD is unclear. To the best of our knowledge, there is a lack of literature on the effect of preparing a rest seat on the existing monolithic zirconia crown in the patient's mouth on the fracture resistance of the crown.
View Article and Find Full Text PDFThis report describes multidisciplinary care combining orthodontics and restorative dentistry for a patient with Class II occlusion and stained mandibular and maxillary resin composite veneers. The orthodontic treatment improved severe overjet and malocclusion prior to restorative care. Occlusal assessment was provided with a novel digital device (PlaneSystem, Zirkonzahn) that is integrated with digital workflows for the evaluation of the occlusal plane and condylar path inclination.
View Article and Find Full Text PDFPurpose: This systematic review and meta-analysis aimed to evaluate the depth distortion and angular deviation of fully-guided tooth-supported static surgical guides (FTSG) in partially edentulous arches compared to partially guided surgical guides or freehand.
Material And Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, and outcome (PICO) question was: "In partially edentulous arches, what are the depth distortion and angular deviation of FTSG compared to partially guided surgical guides or freehand?" The search strategy involved four main electronic databases, and an additional manual search was completed in November 2023 by following an established search strategy.
Background: To evaluate the effectiveness of three minimally invasive techniques for managing patients with myofascial pain dysfunction, determine their association with sociodemographic factors, habits, medication usage, comorbidities, treatment history, pain duration, complaint intensity, and diagnosis limitations.
Material And Methods: This five-year observational study scrutinized 1,000 medical records from individuals treated at the TMD Orofacial Dental Research Center. TMD treatments were organized into Group 1 (thermotherapy, exercises, and CBT), Group 2 (Group 1 plus intramuscular manual therapy), and Group 3 (Group 1 and Group 2 plus occlusal appliances) and correlated with sociodemographic factors, habits, prior medication usage, comorbidities, history of prior treatments, duration of pain, intensity of complaint, and diagnosis limitations or without limitations regarding the symptoms of muscular temporomandibular disorders (TMD).
Focal microdontia is a dental anomaly characterized by the presence of a single abnormally small anterior or posterior tooth. The objective of this article is to provide an updated review of the literature on the advanced restorative management of focal microdontia, and to document a clinical case where the reviewed advanced restorative approaches were applied to treat a young adult presenting with a non-syndromic asymmetrical focal microdontia.We conducted a preliminary examination of the existing literature on the advanced restorative management of focal microdontia.
View Article and Find Full Text PDFBackground: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed.
Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers.
Materials And Methods: Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M).
Purpose: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access.
Materials And Methods: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite.
Aim: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses.
Materials And Methods: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.
Statement Of Problem: Minimally invasive treatments have gained popularity in recent years. However, research comparing the fracture resistance of lithium disilicate partial coverage veneer restorations with that of ceramic crowns is lacking.
Purpose: The purpose of this in vitro study was to evaluate and compare the fracture resistance of lithium disilicate restorations fabricated for preparations of various designs.
Purpose: To evaluate the fracture load of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) veneers fabricated with two conventional pre-crystallized and two fully crystallized lithium disilicate ceramic materials.
Materials And Methods: Seventy-five chairside CAD-CAM veneers (15 specimens/group) for maxillary right central incisors were fabricated with different lithium disilicate brands: (1) IPS e.max CAD; (2) Amber Mill; (3) Cerec Tessera; (4) n!ce Straumann; and (5) GC Initial LiSi Block.