Purpose: Anastomotic leak (AL) remains the most important complication after left-sided colic anastomoses and technical complications during anastomotic construction are responsible of higher leakage incidence. Powered circular stapler (PCS) in colorectal surgery has been introduced in order to reduce technical errors and post-operative complications due to the manual circular stapler (MCS).
Methods: A systematic review and meta-analysis were performed.
Outcomes of laparoscopic procedures for gastroesophageal reflux disease (GERD) are variable depending on surgical expertise and/or patient-related factors. Some procedures may be inadequate in patients with severe disease. Effectiveness of laparoscopic magnetic sphincter augmentation (MSA) has not been extensively tested in patients with severe disease.
View Article and Find Full Text PDFEur J Gastroenterol Hepatol
December 2021
Objective: Normative values for high-resolution manometry (HRM) have been obtained with the patient lying supine. The aim of the study was to compare supine, semirecumbent and sitting positions during HRM in terms of variation in normative metrics, diagnostic yield, and patient's comfort.
Methods: A prospective, single-center feasibility study was planned in consecutive patients referred to the esophageal function laboratory.
Neurogastroenterol Motil
October 2021
Background: Magnetic sphincter augmentation (MSA) is an innovative antireflux procedure that can improve lower esophageal sphincter (LES) competency and reduce symptoms of gastroesophageal reflux disease (GERD). Some patients report postoperative dysphagia. To date, no studies have described reference high-resolution manometry (HRM) values after MSA implantation.
View Article and Find Full Text PDFDiabetes Care
December 2020
Objective: Poor outcomes have been reported in patients with type 2 diabetes and coronavirus disease 2019 (COVID-19); thus, it is mandatory to explore novel therapeutic approaches for this population.
Research Design And Methods: In a multicenter, case-control, retrospective, observational study, sitagliptin, an oral and highly selective dipeptidyl peptidase 4 inhibitor, was added to standard of care (e.g.
Background/aims: According to the Chicago classification version 3.0, high-resolution manometry (HRM) should be performed in the supine position. However, with the patient in the upright/sitting position, the test could more closely simulate real-life behavior and may be better tolerated.
View Article and Find Full Text PDFBackground And Aim: Esophageal foreign bodies, including food bolus impaction, represent a common clinical problem. The prevalence of underlying esophageal disease depends on study design and degree of suspicion of a structural or functional esophageal abnormality. Aim of this study was to analyze factors associated with recurrent impaction.
View Article and Find Full Text PDFBackground: Magnetic sphincter augmentation with the Linx system is a novel laparoscopic procedure for the treatment of gastro-esophageal reflux disease (GERD). Only few data are available regarding the impact of Linx on high-resolution manometry (HRM) variables.
Methods: The prospectively collected database of patients who underwent Linx procedure at a single institution was queried.
Background: Persistent or de novo gastroesophageal reflux disease (GERD) may be a significant clinical issue after gastric/bariatric surgical procedures. We investigated the effect of magnetic sphincter augmentation (MSA) in the treatment of GERD after previous gastric/bariatric surgery.
Database: We conducted a systematic review according to the Preferred Reporting Items For Systematic Reviews and Meta-analyses statement.
Laparoscopic Heller myotomy (LHM), pneumatic dilatation (PD), and peroral endoscopic myotomy (POEM) are common treatments for esophageal achalasia. Literature evidence is restricted to pairwise analysis and PD versus POEM comparison is missing. The aim of this network meta-analysis (NMA) was to comprehensively compare outcomes within these three surgical approaches with those of esophageal achalasia.
View Article and Find Full Text PDFThe esophagus traverses three body compartments (neck, thorax, and abdomen) and is surrounded at each level by vital organs. Injuries to the esophagus may be classified as foreign body ingestion, caustic ingestion, esophageal perforation, and esophageal trauma. These lesions can be life-threatening either by digestive contamination of surrounding structures in case of esophageal wall breach or concomitant damage of surrounding organs.
View Article and Find Full Text PDFNegative allosteric modulators (NAMs) of the metabotropic glutamate receptor 5 (mGlu) hold great promise for the treatment of a variety of central nervous system disorders. We have recently reported that prop-2-ynylidenecycloalkylamine derivatives are potent and selective NAMs of the mGlu receptor. In this work, we explored the amide, carbamate, sulfonamide, and urea derivatives of prop-2-ynylidenecycloalkylamine compounds with the aim of improving solubility and metabolic stability.
View Article and Find Full Text PDFObjective: Esophageal Foreign Body (FB) impaction represents a major challenge for healthcare providers. Aim of this systematic review was to analyse the current literature evidence on prevalence, presentation, treatment, and outcomes of impacted esophageal FB.
Materials And Methods: Literature search was conducted between 2000 and 30th June 2018 according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement.
Background: Foreign body (FB) impaction accounts for 4% of emergency endoscopies in clinical practice. Flexible endoscopy (FE) is recommended as the first-line therapeutic option because it can be performed under sedation, is cost-effective, and is well tolerated. Rigid endoscopy (RE) under general anesthesia is less used but may be advantageous in some circumstances.
View Article and Find Full Text PDFForeign body ingestion is a common event; in the adult population, most ingestions occur in patients with mental disability, psychiatric disorders, alcohol intoxication or in prisoners seeking secondary gain. Removal through flexible endoscopy is generally the first-line approach but rescue oesophagotomy may be necessary for foreign bodies impacted in the upper oesophagus. A 27-year-old man was admitted in the emergency room after intentional ingestion of a wooden spherical object with a central hole.
View Article and Find Full Text PDFArundo donax L. (Giant cane) was used in a full-scale anaerobic digester (AD) plant (power of 380kWhEE) in partial substitution for corn to produce biogas and electricity. Corn substitution was made on a biomethane potential (BMP) basis so that A.
View Article and Find Full Text PDFMetabotropic glutamate receptor 5 (mGlu5) is a biological target implicated in major neurological and psychiatric disorders. In the present study, we have investigated structural determinants of the interaction of negative allosteric modulators (NAMs) with the seven-transmembrane (7TM) domain of mGlu5. A homology model of the 7TM receptor domain built on the crystal structure of the mGlu1 template was obtained, and the binding modes of known NAMs, namely MPEP and fenobam, were investigated by docking and molecular dynamics simulations.
View Article and Find Full Text PDFMesophilic anaerobic digestion (MAD) produces renewable energy, but it also plays a role in reducing the impact of digestates, both by reducing odor and pathogen content. Ten full-scale biogas plants characterized by different plant designs (e.g.
View Article and Find Full Text PDF