Background: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair.
View Article and Find Full Text PDFFront Cardiovasc Med
January 2024
Background: The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD).
View Article and Find Full Text PDFAim: To describe our initial experience with the indications and results of the 5/7 Occlutech® duct Occluder (ODO, Occlutech International AB, Helsingborg, Sweden). A small incremental increase in occluder sizes is of utmost importance for successful outcomes, especially in smaller patients in whom protrusion of the distal disk towards the aorta should be minimised.
Methods: Retrospective study of all patients undergoing PDA closure with the 5/7 ODO in three institutions since 2018.
Persistent patent ductus arteriosus is a very common condition in preterm infants. Although there is no management agreed by consensus, despite numerous randomized controlled trials, hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. Medical treatment is usually offered as first-line therapy, although it carries a limited success rate and potential severe adverse events.
View Article and Find Full Text PDFPediatr Allergy Immunol
January 2023
Catheter Cardiovasc Interv
January 2023
Introduction: The Atrial Flow Regulator (AFR) is a new self-expandable percutaneous-delivered fenestrated device providing an interatrial shunt. Its use in pediatric population has been reported in failing Fontan, pulmonary hypertension, or in patients with cardiomyopathy and venoarterial extracorporeal membrane oxygenator (ECMO) support. Its use in small children under 10 kg has not been reported.
View Article and Find Full Text PDFTranscatheter closure of perimembranous ventricular septal defect is an alternative to surgery in selected small to medium defects with a reasonable distance between the defect and the aortic or tricuspid valves. Surgical closure is generally preferred for large defects with an inlet to outlet extension, aortic malalignment, or deficient aortic rim. We report two successful cases of percutaneous closure of large perimembranous ventricular septal defects with inlet to outlet extension using an Amplatzer Vascular Plug-II via a retrograde approach.
View Article and Find Full Text PDFBackground: Multi-system inflammatory syndrome in children and Kawasaki disease have overlapping clinical features but comparative echocardiographic studies are lacking.
Methods: We reviewed echocardiography findings of all multi-system inflammatory syndrome cases between 1st April and 31st July, 2020 and typical Kawasaki disease patients with coronary arteries abnormalities consecutively followed between 1st October, 2016 and June 30th, 2019.
Results: We included 40 multi-system inflammatory syndrome children (25 males, 62.
Access to complex stenotic pulmonary arteries can be challenging due to their anatomy or secondary to prior multiple surgeries and interventions. Two techniques have been previously described to address this issue: the telescopic catheter-in-long sheath parallel to a stiff guidewire technique and the use of a microcatheter in a telescopic scope. We integrated and modified these techniques creating a super telescopic system with a SuperCross® microcatheter-in-catheter-in-long sheath, parallel to a contralateral stiff guidewire to access a previously repaired and stented left pulmonary artery.
View Article and Find Full Text PDFBackground: The persistent changes in cardiac structure and function in children who survived twin-to-twin transfusion syndrome remain a matter of concern and controversy. Current fetal echocardiographic parameters and their postnatal evolution can help improve our understanding of the subject.
Objective: To describe the echocardiographic changes of monochorionic fetuses affected by twin-to-twin transfusion syndrome, the recipient and the donor, before and after laser photocoagulation and to determine their evolution in the third trimester and during their first year of life.
Background: Transcatheter closure of a patent ductus arteriosus in children is widely performed to reduce symptoms and decrease the risk of endocarditis. Most arterial ducts are closed successfully with dedicated devices. However, in a tubular or "type C" patent ductus arteriosus with congestive heart failure, the occlusion is more challenging with these devices, with a higher risk of complications, such as aortic or left pulmonary stenosis and device embolization.
View Article and Find Full Text PDFBackground: Short-term sequelae of Multisystem Inflammatory Syndrome in Children (MIS-C), recently published by our institution, showed rapid improvement of the cardiac abnormalities within a few weeks after the onset of the disease. However, subtle residual abnormalities, affecting mainly the myocardial interstitium, were shown in some of the patients. The current study aimed to assess myocardial deformation with CMR shortly after MIS-C.
View Article and Find Full Text PDFEur Heart J Case Rep
November 2021
Background: The patient is a 15-year-old male with situs inversus, dextrocardia, bilateral superior caval veins, atrioventricular discordance with a single outlet, large perimembranous ventricular septal defect, aortic override, pulmonary atresia, and right aortic arch. The complex anatomy with a Ventricular Septal Defect (VSD) distant from the aorta (unsuitable for baffling to the aorta) meant he was unsuitable for biventricular repair and proceeded down a univentricular palliation pathway.
Case Summary: Post-total cavopulmonary connection his clinical course was uneventful until the age of 5 when he developed fatigability with desaturation.
Percutaneous closure of secundum atrial septal defect (sASD) in children with interrupted inferior vena cava is challenging, especially in case of deficient aortic rim. Trans-jugular access is generally preferred in this scenario. Patients with situs inversus and sASD also carry technical difficulties for transcatheter closure because of the orientation of the atrial septum.
View Article and Find Full Text PDFBackground: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization.
Case Presentation: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted.
Objectives: To describe presentation, hospital course, and predictors of bad outcome in multisystem inflammatory syndrome in children (MIS-C).
Methods: Retrospective data review of a case series of children meeting the published definition for MIS-C who were discharged or died between March 1, 2020, and June 15, 2020, from 33 participating European, Asian, and American hospitals. Data were collected through a Web-based survey and included clinical, laboratory, electrocardiographic, and echocardiographic findings and treatment management.
Persistent patent ductus arteriosus (PDA) is very common in preterm infants, especially in extremely preterm infants. Despite significant advances in management of these vulnerable infants, there has been no consensus on management of PDA-when should we treat, who should we treat, how should we treat and in fact there is no agreement on how we should define a hemodynamically significant PDA. Medical management with non-steroidal anti-inflammatory drugs (NSAIDs) remains the first line of therapy with moderate success rate in closing the PDA.
View Article and Find Full Text PDFBackground During the SARS-CoV2 pandemic, there has been increase in hyperinflammatory presentation in previously healthy children with a variety of cardiac manifestations. Our objective is to describe the cardiac manifestations found in an international cohort of 55 pediatric cases with multi-system inflammatory syndrome (MIS-C) during the SARS-CoV2 pandemic. Methods and Results We reviewed data on previously healthy pediatric patients (≤18 years) with structurally normal hearts who presented at hospitals in the United States, United Kingdom, Spain and Pakistan with MIS-C and had consultation with a pediatric cardiologist.
View Article and Find Full Text PDFAims: Patent ductus arteriosus (PDA) is common in preterm infants and can contribute to morbidity and mortality. We aimed to compare results and outcome of transcatheter closure using the Amplatzer Piccolo Occluder versus surgical closure in 2 matched groups of preterm infants weighing <3000 g.
Methods And Results: A total of 147 babies from three tertiary centres were retrospectively analysed.