Publications by authors named "Carl Ensfield"

There is considerable interest in portable emissions measurement systems (PEMS) for emission inventory and regulatory applications. For this study, four commercial PEMS were compared with a Federal Reference Method (FRM) for measuring emissions from a back-up generator (BUG) over steady-state loads and a diesel truck on transient and steady-state chassis dynamometer tests. The agreement between the PEMS and the FRM varied depending on the pollutant and the particular PEMS tested for both the BUG and chassis dynamometer testing.

View Article and Find Full Text PDF

A study was performed at a Gordon-Darby centralized inspection and maintenance (I/M) test lane in Phoenix, AZ, in December 1999 for the purpose of evaluating the accuracy of production Vehicle Mass Analysis System (VMAS) equipment relative to standard IM240 equipment. Simultaneous transient mass measurements were made on random vehicles using VMAS and IM240 systems on two test lanes during regular I/M testing. Cumulative mass emissions for 846 valid tests were correlated using least-squares regression analysis.

View Article and Find Full Text PDF