Purpose/objectives: Retrospective analysis suggests that dose escalation to a biologically effective dose of more than 70 Gy may improve overall survival in patients with pancreatic ductal adenocarcinoma (PDAC), but such treatments in practice are limited by proximity of organs at risk (OARs). We hypothesized that CT-guided online adaptive radiotherapy (OART) can account for interfraction movement of OARs and allow for safe delivery of ablative doses.
Materials/methods: This is a single institution retrospective analysis of patients with PDAC treated with OART on the Ethos platform (Varian Medical Systems, a Siemens Healthineers Company, Palo Alto).
Purpose: The emerging online adaptive radiation therapy (OART) treatment strategy based on cone beam computed tomography allows for real-time replanning according to a patient's current anatomy. However, implementing this procedure requires a new approach across the patient's care path and monitoring of the "black box" adaptation process. This study identifies high-risk failure modes (FMs) associated with AI-driven OART and proposes an interdisciplinary workflow to mitigate potential medical errors from highly automated processes, enhance treatment efficiency, and reduce the burden on clinicians.
View Article and Find Full Text PDFAdaptive radiation therapy is a feedback process by which imaging information acquired over the course of treatment, such as changes in patient anatomy, can be used to reoptimize the treatment plan, with the end goal of improving target coverage and reducing treatment toxicity. This review describes different types of adaptive radiation therapy and their clinical implementation with a focus on CT-guided online adaptive radiation therapy. Depending on local anatomic changes and clinical context, different anatomic sites and/or disease stages and presentations benefit from different adaptation strategies.
View Article and Find Full Text PDFObjective: We aim to test the hypothesis that neurovascular bundle (NVB) displacement by rectal hydrogel spacer combined with NVB delineation as an organ at risk (OAR) is a feasible method for NVB-sparing stereotactic body radiotherapy.
Methods: Thirty-five men with low- and intermediate-risk prostate cancer who underwent rectal hydrogel spacer placement and pre-, post-spacer prostate MRI studies were treated with prostate SBRT (36.25 Gy in five fractions).
Background: The Gamma Knife (GK) Icon (Elekta AB) uses a cone-beam computed tomography (CBCT) scanner and an infrared camera system to support the delivery of frameless stereotactic radiosurgery (SRS). There are limited data on patients treated with frameless GK radiosurgery (GKRS).
Objective: To describe the early experience, process, technical details, and short-term outcomes with frameless GKRS at our institution.
Background: Multiple phase I-II clinical trials have reported on the efficacy and safety of prostate stereotactic body radiotherapy (SBRT) for the treatment of prostate cancer. However, few have reported outcomes for prostate SBRT using periprostatic hydrogel spacer (SpaceOAR; Augmenix). Herein, we report safety and efficacy outcomes from our institutional prostate SBRT experience with SpaceOAR placement.
View Article and Find Full Text PDFPurpose: Cone beam computed tomography (CBCT) imaging has been implemented on the Leksell Gamma Knife Icon™ for assessing patient positioning in mask-based Gamma Knife radiosurgery. The purpose of this study was to evaluate the performance of the CBCT-based patient positioning system as a tool for frameless Gamma Knife radiosurgery.
Methods: Daily quality assurance (QA) CBCT precision test results from a 12-month period were analyzed for the geometric accuracy and the stability of the imager.
Background: The SpaceOAR hydrogel is employed to limit rectal radiation dose during prostate radiotherapy. We identified a novel parameter - the product of angle θ and hydrogel volume - to quantify hydrogel placement. This parameter predicted rectum dosimetry and acute rectal toxicity in prostate cancer patients treated with stereotactic body radiotherapy to 36.
View Article and Find Full Text PDFValidation of biodosimetry assays is normally performed with acute exposures to uniform external photon fields. Realistically, exposure to a radiological dispersal device or reactor leak will include exposure to low dose rates and likely exposure to ingested radionuclides. An improvised nuclear device will likely include a significant neutron component in addition to a mixture of high- and low-dose-rate photons and ingested radionuclides.
View Article and Find Full Text PDFIn the event of a nuclear accident or radiological terrorist attack, there will be a pressing need for biodosimetry to triage a large, potentially exposed population and to assign individuals to appropriate treatment. Exposures from fallout are likely, resulting in protracted dose delivery that would, in turn, impact the extent of injury. Biodosimetry approaches that can distinguish such low-dose-rate (LDR) exposures from acute exposures have not yet been developed.
View Article and Find Full Text PDFBackground: The effects of dose-rate and its implications on radiation biodosimetry methods are not well studied in the context of large-scale radiological scenarios. There are significant health risks to individuals exposed to an acute dose, but a realistic scenario would include exposure to both high and low dose-rates, from both external and internal radioactivity. It is important therefore, to understand the biological response to prolonged exposure; and further, discover biomarkers that can be used to estimate damage from low-dose rate exposures and propose appropriate clinical treatment.
View Article and Find Full Text PDFPurpose: To quantify the potential advantages of prone position breast radiotherapy in terms of the radiation exposure to out-of-field organs, particularly, the breast or the lung. Several dosimetric studies have been reported, based on commercial treatment planning software (TPS). These TPS approaches are not, however, adequate for characterizing out-of-field doses.
View Article and Find Full Text PDFBackground: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated.
Methods: Radiation doses from CCTA to critical organs were determined using metal-oxide-semiconductor field-effect transistors positioned in a customized anthropomorphic whole-body dosimetry verification phantom.
Purpose: To determine radiation doses from coronary computed tomographic (CT) angiography performed by using a 320-detector row volume scanner and evaluate how the effective dose depends on scan mode and the calculation method used.
Materials And Methods: Radiation doses from coronary CT angiography performed by using a volume scanner were determined by using metal-oxide-semiconductor field-effect transistor detectors positioned in an anthropomorphic phantom physically and radiographically simulating a male or female human. Organ and effective doses were determined for six scan modes, including both 64-row helical and 280-row volume scans.
Proton radiotherapy represents a potential major advance in cancer therapy. Most current proton beams are spread out to cover the tumor using passive scattering and collimation, resulting in an extra whole-body high-energy neutron dose, primarily from proton interactions with the final collimator. There is considerable uncertainty as to the carcinogenic potential of low doses of high-energy neutrons, and thus we investigate whether this neutron dose can be significantly reduced without major modifications to passively scattered proton beam lines.
View Article and Find Full Text PDFRad9 and Atm regulate multiple cellular responses to DNA damage, including cell cycle checkpoints, DNA repair and apoptosis. However, the impact of dual heterozygosity for Atm and Rad9 is unknown. Using 50 cGy of X rays as an environmental insult and cataractogenesis as an end point, this study examined the effect of heterozygosity for one or both genes in mice.
View Article and Find Full Text PDFThe accelerated appearance of ocular cataracts at younger ages has been recorded in both astronauts and airline pilots, and is usually attributed to high-energy heavy ions in galactic cosmic ray radiation. We have previously shown that high-LET 1-GeV/nucleon (56)Fe ions are significantly more effective than X-rays in producing cataracts in mice. We have also shown that mice haploinsufficient for ATM develop cataracts earlier than wild-type animals, when exposed to either low-LET X-rays or high-LET (56)Fe ions.
View Article and Find Full Text PDFPurpose: To estimate the radiation-related cancer mortality risks associated with single or repeated full-body computed tomographic (CT) examinations by using standard radiation risk estimation methods.
Materials And Methods: The estimated dose to the lung or stomach from a single full-body CT examination is 14-21 mGy, which corresponds to a dose region for which there is direct evidence of increased cancer mortality in atomic bomb survivors. Total doses for repeated examinations are correspondingly higher.