Background And Aims: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI.

Methods: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries.

View Article and Find Full Text PDF

Early treatment of HIV infection increases life expectancy and reduces infectivity; however, delayed HIV diagnosis remains common. Implementation and sustainability of hospital-based routine HIV testing in Vancouver, British Columbia, was evaluated to address a local HIV epidemic by facilitating earlier diagnosis and treatment. Public health issued a recommendation in 2011 to offer HIV testing to all patients presenting to three Vancouver hospitals as part of routine care, including all patients admitted to medical/surgical units with expansion to emergency departments (ED).

View Article and Find Full Text PDF

Aims: Multiple surgical revisions are often necessary in individuals with congenital heart defects affecting the RVOT or pulmonary valve. There are no multicentre data on the feasibility and safety of percutaneous pulmonary valve implantation (PPVI) using the SAPIEN 3 (S3) transcatheter heart valve. The aim of this study was to explore the short-term safety, feasibility, and haemodynamic outcomes of PPVI using the S3 transcatheter heart valve.

View Article and Find Full Text PDF

Background: Patients with congenital or acquired heart defects affecting the pulmonary valve and right ventricular outflow tract (RVOT) commonly require multiple surgical interventions, resulting in significant morbidity. A less invasive alternative is percutaneous pulmonary valve implantation (PPVI). Though studies have previously reported the safety and efficacy of the early generation transcatheter heart valves (THVs), data on more recent devices are severely lacking.

View Article and Find Full Text PDF

A 59-year-old female with Tetralogy of Fallot had a previous complete repair with RVOT patch enlargement. She developed subsequent severe symptomatic (NYHA III) pulmonary regurgitation with severe RV dilatation. She had a concomitant interstitial lung disease secondary to hypersensitivity pneumonitis that precluded her from cardiac surgery.

View Article and Find Full Text PDF

Currently there are more than 40 centres in Canada that perform more than 65,000 percutaneous coronary interventions (PCIs) in a year. Considering the high volume of procedures and number of operators, the potential for variation in processes of care is high, and might lead to variation in the quality of care. As part of its quality initiative, the Canadian Cardiovascular Society convened a working group to develop a set of PCI Quality Indicators (QIs) that would be relevant, scientifically acceptable, and feasible to measure and report.

View Article and Find Full Text PDF

Background: Markers of plaque destabilization and disruption may have a role in identifying non-STE- type 1 Myocardial Infarction in patients presenting with troponin elevation. We hypothesized that a plaque disruption index (PDI) derived from multiple biomarkers and measured within 24 hours from the first detectable troponin in patients with acute non-STE- type 1 MI (NSTEMI-A) will confirm the diagnosis and identify these patients with higher specificity when compared to individual markers and coronary angiography.

Methods: We examined 4 biomarkers of plaque destabilization and disruption: myeloperoxidase (MPO), high-sensitivity interleukin-6, myeloid-related protein 8/14 (MRP8/14) and pregnancy-associated plasma protein-A (PAPP-A) in 83 consecutive patients in 4 groups: stable non-obstructive coronary artery disease (CAD), stable obstructive CAD, NSTEMI-A (enrolled within 24 hours of troponin positivity), and NSTEMI-L (Late presentation NSTEMI, enrolled beyond the 24 hour limit).

View Article and Find Full Text PDF

Background: Guidelines recommend clopidogrel use for 6-12 months following drug-eluting stent (DES) implantation and 1-12 months following bare metal stent (BMS) implantation. The role of clopidogrel beyond 12 months is unclear.

Methods: We linked hospital administrative, community pharmacy and cardiac revascularization data to determine clopidogrel use and outcomes for all patients (those with acute presentations and those with stable angina) receiving a coronary stent in British Columbia 2004-2006, with follow-up until the end of 2008.

View Article and Find Full Text PDF

This position statement addresses issues in revascularization for multivessel coronary artery disease (CAD) from the perspective of both cardiologists and cardiac surgeons. Recommendations are made based on evidence from clinical trials and observational studies, with an emphasis on the increasing number of individuals with significant comorbid disease burden and functional debilitation who are being referred for definitive management of their multivessel CAD in the context of routine clinical practice. These types of individuals have traditionally not been included in the many clinical trials that have been the basis for guidelines and recommendations, and the objective of the proposed medical intervention or revascularization (or both) would not necessarily be to improve prognosis but to improve quality of life.

View Article and Find Full Text PDF

Background: Patients frequently experience difficulties with medication compliance after hospital discharge. We investigated the effect of a delay in filling a first clopidogrel prescription after hospital discharge on clinical outcomes subsequent to coronary stenting.

Methods And Results: Hospital administrative, community pharmacy, and cardiac revascularization data were determined for all patients receiving a coronary stent in British Columbia 2004-2006 with follow-up out to 2 years.

View Article and Find Full Text PDF

Background: Coronary angiography remains the most widely used tool for routine screening and diagnosis of cardiac allograft vasculopathy (CAV), a major pathologic process that develops in 50% of cardiac transplant recipients beyond the first year after transplant. Given the invasiveness, expense, discomfort, and risk of complications associated with angiography, a minimally invasive alternative that is sensitive and specific would be highly desirable for monitoring CAV in patients.

Methods: Plasma proteomic analysis using isobaric tags for relative and absolute quantitation-matrix-assisted laser desorption ionization double time-of-flight mass spectrometry was carried out on samples from 40 cardiac transplant patients (10 CAV, 9 non-significant CAV, 21 possible CAV).

View Article and Find Full Text PDF

We report the innovation of both a partly-covered and completely-covered, variable-diameter, balloon-expandable stent that was custom-designed by NuMed, Inc for percutaneous closure of a baffle leak after total caval pulmonary connection (TCPC). A 50-year-old patient, born with tricuspid atresia, who had undergone TCPC, developed severe persistent cyanosis due to a right-to-left shunt through a TCPC baffle leak. Re-operation was deemed too high risk.

View Article and Find Full Text PDF

The short lifespan of right ventricle-to-pulmonary artery (RV-PA) conduits used in repairs of complex congenital heart defects makes future surgical replacement inevitable. Percutaneous pulmonary valve implantation (PPVI) now offers an attractive alternative to surgery in some patients. The objectives of this study were to examine the pattern of conduit reoperations, the factors affecting conduit longevity, and to discuss the role of PPVI in these patients.

View Article and Find Full Text PDF

Although the treatment of aortic coarctation in adults with the use of stents has shown favourable results and reduced complications, there have been few studies involving elderly patients. We highlight the clinical challenges faced in the management of such patients, with attention to severe calcification at the coarctation site. The midterm results were good in our patient, showing an improvement in blood pressure control and maintenance of stent patency.

View Article and Find Full Text PDF

Objectives: This study sought to report on the pathology of transcatheter aortic valves explanted at early and late time points after transcatheter aortic valve implantation.

Background: Information on pathological findings following transcatheter aortic valve implantation is scarce, particularly late after transcatheter aortic valve implantation.

Methods: This study included 20 patients (13 men, median age 80 years [interquartile range: 72 to 84] years) with previous transcatheter aortic valve implantation with a valve explanted at autopsy (n = 17) or surgery (n = 3) up to 30 months after implantation (10 transapical and 10 transfemoral procedures).

View Article and Find Full Text PDF

Objectives: This study assesses if there exists a high-risk period for cerebrovascular events (CeV) after transcatheter aortic valve implantation (TAVI).

Background: Even though acute strokes after TAVI have been described, it is uncertain if stroke rates continue to remain high in the early months after TAVI. Furthermore, the optimal dose and duration of thromboprophylaxis is unclear.

View Article and Find Full Text PDF

Objectives: This study aims to assess the mid- to long-term follow-up of patients after valve embolization at the time of transcatheter aortic valve implantation (TAVI).

Background: Transcatheter heart valve (THV) embolization is a rare but serious complication during TAVI. Although various techniques have been developed to manage acute complications and reduce periprocedural morbidity/mortality, long-term clinical and hemodynamic consequences after these events are unknown.

View Article and Find Full Text PDF

Background: Bleeding following percutaneous coronary intervention (PCI) is common and may lead to transfusion and death. Although previous work has examined the effect of red blood cell (RBC) transfusion in patients with coronary disease, no study had investigated whether transfusion of non-RBC components was associated with mortality following PCI.

Methods: All subjects transfused in the 10 days following PCI were identified using the British Columbia Cardiac and Central Transfusion Registries.

View Article and Find Full Text PDF

Transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves have been reported. This strategy avoids performing high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has not been described.

View Article and Find Full Text PDF

Background: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited.

Methods And Results: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed.

View Article and Find Full Text PDF

More than 1/4 of patients who undergo invasive coronary angiography are found to have no visible or nonobstructive (<50% stenosis) coronary artery disease (CAD). With the rapid evolution of noninvasive imaging for CAD diagnosis, avoiding invasive coronary angiography in patients unlikely to require coronary revascularization is desirable. We undertook to develop a clinical prediction tool to identify patients with a low likelihood of obstructive (> or =50% stenosis) CAD.

View Article and Find Full Text PDF

Objectives: Endovascular stenting of aneurysms late after surgical repair of coarctation may have to deal with marked changes in aortic diameter proximal and distal to the aneurysm. We report our first-in-man successful use of a custom-made tapered (variable diameter) covered stent.

Methods: The aneurysm was 42 mm in diameter with a length of 40 mm.

View Article and Find Full Text PDF

Background: Blood transfusion has been associated with an increased mortality in patients undergoing percutaneous coronary intervention (PCI). Although the reasons for this remain unclear, it may be related to the structural and functional changes occurring within red blood cells (RBCs) during storage. We investigated whether RBC storage duration was associated with mortality in patients requiring transfusion after PCI.

View Article and Find Full Text PDF

Background: We performed the first human case of successful transapical transcatheter aortic valve implantation on a beating heart in October 2005, and therefore we have the longest follow-up on transapical aortic valve implantation in humans. We now report clinical and echocardiographic outcomes of transapical aortic valve implantation in 71 patients.

Methods: Between October 2005 and February 2009, 71 patients (44 female) underwent transcatheter transapical aortic valve implantation with either 23- or 26-mm Edwards Lifesciences transcatheter bioprostheses.

View Article and Find Full Text PDF

Background: The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative.

View Article and Find Full Text PDF