Publications by authors named "Cardiff P"

This paper presents an adaption of the finite-element based beam-to-beam contact interactions into a finite volume numerical framework. A previous work of the same authors, where a cell-centred based finite volume implementation of geometrically exact nonlinear Simo-Reissner beams was developed, is used as an underlying mathematical model. An implicit contact procedure is developed for both point-to-point and line-to-line beam frictionless contact interactions, and is implemented using the cell-centred finite volume method.

View Article and Find Full Text PDF

The assessment of stent fatigue in Transcatheter Aortic Valve Replacement (TAVR) systems is critical for the design of next-generation devices, both in vitro and in vivo. The mechanical properties of the bioprosthetic heart valves (BHVs) have a significant impact on the fatigue life of the metallic stent and thus must be taken into consideration when evaluating new TAVR device designs. This study aims to investigate the relationship between BHV anisotropic behaviour and the asymmetric deflections of the stent frame observed during in vitro testing.

View Article and Find Full Text PDF

The aim of the current study was to understand the importance of the joint alignment following triple arthrodesis by analysing the contact characteristics in a normal and arthritic ankle joint using a patient-specific numerical model developed using open source software. The alignment of the hindfoot with respect to tibia is calculated from CT scans and the ankle joint model was numerically analysed for neutral, valgus and varus positions in both normal and arthritic conditions. The contact area, the magnitude and distribution of the contact pressure on the articular surface of the talar dome was evaluated using a cell-centred Finite Volume Method implemented in open-source software OpenFOAM.

View Article and Find Full Text PDF

The properties of intracranial aneurysms (IAs) walls are known to be driven by the underlying hemodynamics adjacent to the IA sac. Different pathways exist explaining the connections between hemodynamics and local tissue properties. The emergence of such theories is essential if one wishes to compute the mechanical response of a patient-specific IA wall and predict its rupture.

View Article and Find Full Text PDF

Numerical simulations have been extensively used in the past two decades for the study of intracranial aneurysms (IAs), a dangerous disease that occurs in the arteries that reach the brain and affect overall 3.2% of a population without comorbidity with up to 60% mortality rate, in case of rupture. The majority of those studies, though, assumed a rigid-wall model to simulate the blood flow.

View Article and Find Full Text PDF

This article presents a novel total Lagrangian cell-centered finite volume formulation of geometrically exact beams with arbitrary initial curvatures undergoing large displacements and finite rotations. The choice of rotation parameterization, the mathematical formulation of the beam kinematics, conjugate strain measures, and the linearization of the strong form of governing equations are described. The finite volume based discretization of the computational domain and the governing equations for each computational volume are presented.

View Article and Find Full Text PDF

Toe caps are one of the most important components in safety footwear, but have a significant contribution to the weight of the shoe. Efforts have been made to replace steel toe caps by polymeric ones, since they are lighter, insulated and insensitive to magnetic fields. Nevertheless, polymeric solutions require larger volumes, which has a negative impact on the shoe's aesthetics.

View Article and Find Full Text PDF

A patient-specific numerical model of the ankle joint has been developed using open-source software with realistic material properties that mimics the physiological movement of the foot during the stance phase of the gait cycle. The patient-specific ankle geometry has been segmented as a castellated surface using 3DSlicer from the computed tomography image scans of a subject with no congenital or acquired pathology; subsequently, the bones are smoothed, and cartilage is included as a uniform thickness extruded layer. A high-resolution Cartesian mesh has been generated using cfMesh.

View Article and Find Full Text PDF

A good understanding of the mechanical stability of biofilms is essential for biofouling management, particularly when mechanical forces are used. Previous biofilm studies lack a damage-based theoretical model to describe the biofilm separation from a surface. The purpose of the current study was to investigate the interfacial separation of a mature biofilm from a rigid glass substrate using a combined experimental and numerical modelling approach.

View Article and Find Full Text PDF

Forces generated in the muscles and tendons actuate the movement of the skeleton. Accurate estimation and application of these musculotendon forces in a continuum model is not a trivial matter. Frequently, musculotendon attachments are approximated as point forces; however, accurate estimation of local mechanics requires a more realistic application of musculotendon forces.

View Article and Find Full Text PDF

This paper establishes a procedure for numerical analysis of a hip joint using the finite volume method. Patient-specific hip joint geometry is segmented directly from computed tomography and magnetic resonance imaging datasets and the resulting bone surfaces are processed into a form suitable for volume meshing. A high resolution continuum tetrahedral mesh has been generated, where a sandwich model approach is adopted; the bones are represented as a stiffer cortical shells surrounding more flexible cancellous cores.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiondbij15cid192gtju7ogeoup8j3m6sini): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once