The historical restriction of magnetic resonance imaging (MRI) for patients with cardiac implantable electronic devices (CIEDs) has been lifted by certified MRI-conditional systems in recent years. Mixed-brand CIED systems consisting of a generator from one manufacturer and at least one lead from another manufacturer are not certified for MRI. We evaluated the temporal trend in the prevalence of mixed-brand systems in the era of MRI-conditional systems.
View Article and Find Full Text PDFBackground: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE.
Objective: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence.
Aims: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies.
Methods And Results: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres.
Aims: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket.
View Article and Find Full Text PDFIntroduction: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds).
Methods And Results: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort.
Background: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood.
Objectives: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS).
Methods: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds).
Resilience is proven as a protective factor against the development of psychiatric disorders, and it has gained clinical relevance in the development and progression of cardiovascular pathology. The authors performed a longitudinal study on patients with implantable cardioverter defibrillator (ICD) with the primary aim to highlight the possible existence of a correlation between individual resilience capacity, depressive and anxiety symptoms, and quality of life in terms of outcomes. The secondary aim was to analyze the differences between patients with major cardiac events in the follow-up and patients without cardiac events with respect to the previous variables.
View Article and Find Full Text PDFPurpose: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients.
Methods: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry.
Results: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables.
Aims: There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation.
Methods And Results: We retrospectively analysed remote monitoring data from 1141 CRT defibrillators.
Late-onset migration of pacing leads in the left hemithorax is a rare but potentially life-threatening complication. Radiological examinations are required to detect any involvement of either left ventricle or lung parenchyma, prompting immediate surgical extraction in this setting. Identification of high-risk patients is mandatory to prevent this complex iatrogenic complication.
View Article and Find Full Text PDFIntroduction: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D).
Methods: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated.
Background: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted.
Aims: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique.
Aims: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing.
View Article and Find Full Text PDFIn patients with PLSVC, the use of an active fixation lead (like the Medtronic "Attain Stability") on the coronary sinus can lead to a successful and safe cardiac resynchronization, facilitating its positioning with a low long-term displacement rate.
View Article and Find Full Text PDFBackground: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D).
Methods: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE).
: In recent years, the increasing number of patients with a cardiac implantable electronic device (CIED) has required different approaches in terms of the device's control and surveillance. It is increasingly difficult to keep the traditional in-office protocol device's control: we must think of a different organization dedicated to the activity of remote control and monitoring (RC/RM) of devices and patients.A CIED team structured with nurses, technicians and physicians should be organized inside the hospital, with the aim of CIED patients' managing and of creating a network between the various departments.
View Article and Find Full Text PDFBackground: A two-incision technique, in association with inter-muscular positioning of the subcutaneous defibrillator (S-ICD), is now the most frequently adopted implantation approach in Europe. Ultrasound-guided serratus anterior plane block (SAPB) has been proposed to provide anesthesia/analgesia during S-ICD implantation.
Objective: We performed a case-control analysis in which a standardized SAPB approach was compared with the typical local anesthesia and sedation approach.
Objectives: This study evaluated the temporal association between atrial high-rate episodes (AHREs) and sustained ventricular arrhythmias (VAs) in a remotely monitored cohort with implantable cardioverter-defibrillators (ICD) with and/or without cardiac resynchronization therapy with a defibrillator (CRT-D).
Background: Clinical relevance of AHREs in terms of VA rate and survival has not been outlined yet.
Methods: This study analyzed data of patients with ICDs and CRT-Ds from the nationwide Home Monitoring Expert Alliance network.
Background: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor.
Hypothesis: The presence of an association between RR and the incidence of AHREs.
Introduction: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients.
Methods And Results: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network.