Publications by authors named "Canan Bural"

This in vitro study was conducted to investigate the repeatability of the implant stability quotients (ISQ) measured with multipegs after numerous sterilizations and to detect the exact time when the readings start to deviate. Multipegs were sterilized with 3 different methods (autoclaved, autoclaved + ultrasonic cleaner, chemical disinfection + autoclaved) and grouped according to the method applied. All specimens were put into the autoclave with sealed packages every time they were sterilized.

View Article and Find Full Text PDF

Purpose: The validated translations of the OHIP-EDENT exist in different languages; however, there is no reliable and validated Turkish translation. The present study was conducted to evaluate the reliability and to validate the Oral Health Impact Profile in edentulous subjects translated to Turkish (OHIP-EDENT-T).

Materials And Methods: The study sample included 104 conventional complete denture wearers (58 women and 46 men, mean age: 61.

View Article and Find Full Text PDF

The establishment of dental implant stability is mandatory for successful osseointegration. Resonance frequency analysis (RFA) is the most frequently used method for the clinical measurement of implant stability. The purpose of the present study was to evaluate the reliability of the recently developed RF analyzer Penguin RFA and to compare it with the traditional RF analyzer Osstell ISQ.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the color stability of a heat polymerized resin, an auto-polymerizing resin, a urethane dimethacrylate resin and a CAD/CAM PMMA block resin stored in different storage media.

Materials And Methods: 60 disc-shaped specimens (15×2 mm) were fabricated for each group. A total of 240 disc-shaped specimens were thermal-cycled for 5,000 cycles.

View Article and Find Full Text PDF

The design of an implant has a great effect on primary stability. The purpose of this study was to determine the differences in primary stability between straight and tapered Neoss ProActive implants in type I and type III bones using resonance frequency analysis (RFA) and electronic percussive testing (EPT) methods. Fresh cow vertebrae and pelvis were used as models of type III and type i bone, respectively.

View Article and Find Full Text PDF

Background: It is unknown whether it is possible to measure implant stability with polyetheretherketone (PEEK) healing abutments using electronic percussive testing (EPT).

Purpose: To investigate the reliability of the percussive test values (PTVs) measured with PEEK healing abutments and to compare them with the PTVs measured with titanium healing abutments.

Material And Methods: Thirty dental implants were inserted into the fresh pelvis belonging to a cow.

View Article and Find Full Text PDF

Purpose: To investigate the effects of over-the-counter products on the healing of denture-induced ulcerations and patients' self-reported pain.

Materials And Methods: A total of 140 patients with acute denture-induced ulcerations were randomized into seven treatment groups: denture grinding (control); topical application of corn oil gel (placebo); triester glycerol oxide gel; D-panthenol gel; D-panthenol mouthwash; L-arginine mouthwash; and hyaluronic acid gel. Healing and self-reported pain were assessed after 1, 3, and 7 days of treatment.

View Article and Find Full Text PDF

This case report describes the fabrication of a distal extension removable partial denture (RPD) of a 65-year-old man with implant support. Loss of fibroelasticity of the peripheral tissues and reduced mandibular vestibular sulcular depth due to a previous surgical resection and radiotherapy at the right side were the main clinical factors that created difficulty for denture retention and stability. The fabrication of a mandibular RPD supported by anterior teeth and two bilaterally placed implants in the molar area to convert from Kennedy Class 1 design to Kennedy Class 3 implant-bounded RPD is reported.

View Article and Find Full Text PDF

Purpose: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone.

Materials And Methods: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively.

View Article and Find Full Text PDF

The aim of this study was to find an optimal value for tightening the Smartpegs for magnetic radiofrequency analysis devices (RFAs) devices. Thirty implants were placed in 3 cow ribs. The RFA value of each implant was measured in buccal and mesial directions after tightening the Smartpegs with 1, 3, 4, 8, 9, 10, and 11 Ncm.

View Article and Find Full Text PDF

Background: A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device.

Methods: Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.

View Article and Find Full Text PDF

Periotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs.

View Article and Find Full Text PDF

Purpose: To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants.

Material And Methods: Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed.

Results: The success rate was lower for short and maxillary implants.

View Article and Find Full Text PDF

Purpose: This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well as the location, dimension and type of the implants.

Materials And Methods: The data of demographics (age and gender), type of indication for implant therapy, anatomical location, dimensions (length and diameter) and type (bone and tissue level) of 1616 implants were recorded from patient charts between January 2000 and January 2010. Descriptive statistics were analyzed using a chi-squared test for demographic parameters, type of indication, tooth position, anatomical location, implant dimensions and type (α=.

View Article and Find Full Text PDF

Titanium and its alloys have been widely used for dental prosthetic devices because of their superior mechanical properties and biocompatibility. However, the incidence of titanium hypersensitivity or allergy is still unknown and the discussion about its existence is ongoing. Unexplained implant failures have also forced dental clinicians to investigate the possibility of titanium hypersensitivity or allergy.

View Article and Find Full Text PDF

Statement Of Problem: The closest speaking space (CSS) together with the vertical overlap of anterior teeth during the production of the /s/ sound have not been previously investigated with respect to differences in dental and skeletal orthodontic classifications.

Purpose: The purpose of this study was to investigate the CSS in dental and skeletal occlusions and to analyze the cause and effect relationship of the CSS and the amount of the vertical overlap of anterior teeth.

Material And Methods: Poly vinylsiloxane interocclusal registration material was placed bilaterally onto the occlusal surfaces of premolar and molar teeth of 155 native Turkish speaking adolescent and young adult dentate participants, who were then asked to pronounce the word seyis.

View Article and Find Full Text PDF

Oligodontia is the agenesis of 6 or more teeth, excluding third molars. The etiology of congenital absence of teeth is believed to be rooted in heredity or developmental anomalies. The absence of teeth in patients can cause aesthetic, functional, and psychological problems, particularly if the anterior region is involved.

View Article and Find Full Text PDF

Objectives: Residual methyl methacrylate (MMA) may leach from the acrylic resin denture bases and have adverse effects on the oral mucosa. This in vitro study evaluated and correlated the effect of the leaching residual MMA concentrations ([MMA]r) on in vitro cytotoxicity of L-929 fibroblasts.

Material And Methods: A total of 144 heat-polymerized acrylic resin specimens were fabricated using 4 different polymerization cycles: (1) at 74ºC for 9 h, (2) at 74ºC for 9 h and terminal boiling (at 100ºC) for 30 min, (3) at 74ºC for 9 h and terminal boiling for 3 h, (4) at 74ºC for 30 min and terminal boiling for 30 min.

View Article and Find Full Text PDF

Objectives: This study evaluated the effect of post-polymerization heat-treatments on degree of conversion (DC), residual methyl methacrylate concentration (MMA(r)) and in vitro cytotoxicity of autopolymerizing acrylic repair resin.

Methods: A total of 336 specimens were prepared by bench- and hydroflask-curing and subjected to post-polymerization heat-treatments: a) water immersion at 60°C for 30 min, b) microwaving at 500 W for 3 min, c) combined use of water immersion and microwaving d) no treatment (as control). Specimens were eluted in cell culture medium for 1, 2, 5 and 7 days.

View Article and Find Full Text PDF

Prosthetic management of maxillectomy cases is challenging, and a multidisciplinary approach is usually needed. This clinical report describes the treatment provided to a patient who presented with a moderately differentiated squamous cell carcinoma. A two-stage surgical protocol was followed for this purpose.

View Article and Find Full Text PDF

Objectives: Repair strength can be improved by treating fractured surfaces of a denture.

Background: This study investigated flexural properties of heat-polymerised acrylic resin specimens repaired with auto-polymerising and visible light curing (VLC) resins after the repair surfaces were wetted with monomers or acetone.

Materials And Methods: Fifty-four specimens (65 x 10 x 2.

View Article and Find Full Text PDF

Background/aims: End-stage renal disease (ESRD) patients have an increased risk of atherosclerotic complications. In both hemodialysis (HD) patients and the general population, it has become evident that inflammation plays an important role in the pathogenesis of atherosclerotic complications. Oral and dental problems in ESRD patients could be an important source of inflammation, thus treatment of these problems is important to protect these patients from potential infections.

View Article and Find Full Text PDF

Background. In previous studies, the oral and dental health statuses were compared in hemodialysis (HD) and peritoneal dialysis (PD) patients without taking into account the effect of educational levels on oral health. Hence we aimed to make a comparison of these parameters based upon the subjects educational levels.

View Article and Find Full Text PDF

For the partially edentulous patient, an interim denture can provide acceptable short-term function and esthetics by replacing missing teeth and tissues until a definitive restoration can be performed. This article presents two cases that required interim removable partial dentures to maintain function, phonation, and esthetics until clinical conditions allowed for the fabrication of definitive dentures.

View Article and Find Full Text PDF

This study compared the influence of different polymerization methods (heat, auto-, and microwave energy), different curing processes (in the case of heat- and autopolymerized specimens), and length of storage of the polymerized specimens in distilled water at 37 degrees C on the residual methyl methacrylate (MMA) content in dental acrylic resin specimens. Residual MMA of 120 resin specimens were measured using high-performance liquid chromatography. For the heat-polymerized resins, the lowest residual MMA content was obtained when they were given a long-term terminal boil and then stored in the distilled water for at least 1 day.

View Article and Find Full Text PDF