Int J Numer Method Biomed Eng
June 2024
In microwave imaging, the adjoint method is widely used for the efficient calculation of the update direction, which is then used to update the unknown model parameter. However, the utilization and the formulation of the adjoint method differ significantly depending on the imaging scenario and the applied optimization algorithm. Because of the problem-specific nature of the adjoint formulations, the dissimilarities between the adjoint calculations may be overlooked.
View Article and Find Full Text PDFMagnetic particle imaging (MPI) offers unparalleled contrast and resolution for tracing magnetic nanoparticles. A common imaging procedure calibrates a system matrix (SM) that is used to reconstruct data from subsequent scans. The ill-posed reconstruction problem can be solved by simultaneously enforcing data consistency based on the SM and regularizing the solution based on an image prior.
View Article and Find Full Text PDFIEEE Trans Med Imaging
December 2022
Magnetic particle imaging (MPI) offers exceptional contrast for magnetic nanoparticles (MNP) at high spatio-temporal resolution. A common procedure in MPI starts with a calibration scan to measure the system matrix (SM), which is then used to set up an inverse problem to reconstruct images of the MNP distribution during subsequent scans. This calibration enables the reconstruction to sensitively account for various system imperfections.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Magnetic Particle Imaging (MPI) is a new imaging technique that allows high resolution & high frame-rate imaging of magnetic nanoparticles (MNP). It relies on the nonlinear response of MNPs under a magnetic field. The imaging process can be modeled linearly, and then image reconstruction can be case as an inverse problem using a measured system matrix (SM).
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Magnetic Particle Imaging (MPI) is an emerging modality that images the magnetic nanoparticle distribution inside the body. The method is based on the non-linear response of the magnetic nanoparticles to an applied magnetic field. In this study, we present simulation results for three-dimensional (3D) tomographic imaging using an open-bore MPI system that can electronically scan a field free line (FFL).
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2021
Angular spectrum (AS) methods enable efficient calculation of wave propagation from one plane to another inside homogeneous media. For wave propagation in heterogeneous media such as biological tissues, AS methods cannot be applied directly. Split-stepping techniques decompose the heterogeneous domain into homogeneous and perturbation parts, and provide a solution for forward wave propagation by propagating the incident wave in both frequency-space and frequency-wavenumber domains.
View Article and Find Full Text PDFIEEE Trans Med Imaging
December 2020
Superparamagnetic iron oxide nanoparticles (SPIONs) have a high potential for use in clinical diagnostic and therapeutic applications. In vivo distribution of SPIONs can be imaged with the Magnetic Particle Imaging (MPI) method, which uses an inhomogeneous magnetic field with a field free region (FFR). The spatial distribution of the SPIONs are obtained by scanning the FFR inside the field of view (FOV) and sensing SPION related magnetic field disturbance.
View Article and Find Full Text PDFIEEE Trans Med Imaging
September 2019
Magnetic particle imaging (MPI) is a relatively new medical imaging modality, which detects the nonlinear response of magnetic nanoparticles (MNPs) that are exposed to external magnetic fields. The system matrix (SM) method for MPI image reconstruction requires a time consuming system calibration scan prior to image acquisition, where a single MNP sample is measured at each voxel position in the field-of-view (FOV). The scanned sample has the maximum size of a voxel so that the calibration measurements have relatively poor signal-to-noise ratio (SNR).
View Article and Find Full Text PDFPurpose: Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (FFP), or a field free line (FFL), in which the magnetic field vanishes at a point, or on a line, respectively. FFL scanning has the advantage of improved sensitivity compared to FFP scanning as a result of higher signal-to-noise ratio.
View Article and Find Full Text PDFHarmonic motion microwave Doppler imaging (HMMDI) is a novel imaging modality for imaging the coupled electrical and mechanical properties of body tissues. In this paper, we used two experimental systems with different receiver configurations to obtain HMMDI images from tissue-mimicking phantoms at multiple vibration frequencies between 15 Hz and 35 Hz. In the first system, we used a spectrum analyzer to obtain the Doppler data in the frequency domain, while in the second one, we used a homodyne receiver that was designed to acquire time-domain data.
View Article and Find Full Text PDFThis study investigated thermal ablation and skull-induced heating with a 230 kHz transcranial MRI-guided focused ultrasound (TcMRgFUS) system in nonhuman primates. We evaluated real-time acoustic feedback and aimed to understand whether cavitation contributed to the heating and the lesion formation. In four macaques, we sonicated thalamic targets at acoustic powers of 34-560 W (896-7590 J).
View Article and Find Full Text PDFPurpose: Thermal ablation with transcranial MRI-guided focused ultrasound (FUS) is currently limited to central brain targets because of heating and other beam effects caused by the presence of the skull. Recently, it was shown that it is possible to ablate tissues without depositing thermal energy by driving intravenously administered microbubbles to inertial cavitation using low-duty-cycle burst sonications. A recent study demonstrated that this ablation method could ablate tissue volumes near the skull base in nonhuman primates without thermally damaging the nearby bone.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
October 2015
Harmonic Motion Microwave Doppler Imaging (HMMDI) method is recently proposed as a non-invasive hybrid breast imaging technique for tumor detection. The acquired data depend on acoustic, elastic and electromagnetic properties of the tissue. The potential of the method is analyzed with simulation studies and phantom experiments.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
October 2015
Harmonic Motion Microwave Doppler Imaging (HMMDI) is a hybrid method proposed for breast tumor detection, which images the coupled dielectric and elastic properties of the tissue. In this paper, the performance of a data acquisition system for HMMDI method is evaluated on breast phantom materials. A breast fat phantom including fibro-glandular and tumor phantom regions is produced.
View Article and Find Full Text PDFIEEE Trans Med Imaging
February 2014
A hybrid method for tissue imaging using dielectric and elastic properties is proposed and investigated with simple bi-layered breast model. In this method, local harmonic motion is generated in the tissue using a focused ultrasound probe. A narrow-band microwave signal is transmitted to the tissue.
View Article and Find Full Text PDF