Publications by authors named "Campen D"

Here, we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm, allowing for multiple samples and/or large samples to be mounted.

View Article and Find Full Text PDF

Objective: In the last decade, repetitive transcranial magnetic stimulation (rTMS) has been introduced as a non-invasive neuromodulation therapy for depression. Little is known, however, about (serious) adverse events (AE) of rTMS in older adults with a depression. In this article, we want to study what is known about (serious) AE of rTMS in older adults (>60 years) with late-life depression (LLD).

View Article and Find Full Text PDF

This paper describes a new large-range rapid-scan X-ray fluorescence (XRF) imaging station at beamline 6-2 at the Stanford Synchrotron Radiation Lightsource at SLAC National Accelerator Laboratory. This station uses a continuous rapid-scan system with a scan range of 1000 × 600 mm and a load capacity of up to 25 kg, capable of 25-100 µm resolution elemental XRF mapping and X-ray absorption spectroscopy (XAS) of a wide range of objects. XRF is measured using a four-element Hitachi Vortex ME4 silicon drift detector coupled to a Quantum Detectors Xspress3 multi-channel analyzer system.

View Article and Find Full Text PDF

Vanadium and its surface oxides were studied as a potential nitrogen-selective membrane material for indirect carbon capture from coal or natural gas power plants. The effects of minor flue gas components (SO, NO, NO, HO, and O) on vanadium at 500-600 °C were investigated by thermochemical exposure in combination with X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and in situ X-ray diffraction (XRD). The results showed that SO, NO, and NO are unlikely to have adsorbed on the surface vanadium oxides at 600 °C after exposure for up to 10 h, although NO and NO may have exhibited oxidizing effects (e.

View Article and Find Full Text PDF

Investment in brighter sources and larger and faster detectors has accelerated the speed of data acquisition at national user facilities. The accelerated data acquisition offers many opportunities for the discovery of new materials, but it also presents a daunting challenge. The rate of data acquisition far exceeds the current speed of data quality assessment, resulting in less than optimal data and data coverage, which in extreme cases forces recollection of data.

View Article and Find Full Text PDF

Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. Here we present the application of radiative thermal annealing, an easily scalable processing method for synthesizing formamidinium lead iodide (FAPbI) perovskite solar absorbers.

View Article and Find Full Text PDF

Combinatorial materials science strategies have accelerated materials development in a variety of fields, and we extend these strategies to enable structure-property mapping for light absorber materials, particularly in high order composition spaces. High throughput optical spectroscopy and synchrotron X-ray diffraction are combined to identify the optical properties of Bi-V-Fe oxides, leading to the identification of BiVFeO as a light absorber with direct band gap near 2.7 eV.

View Article and Find Full Text PDF

Typical X-ray diffraction measurements are made by moving a detector to discrete positions in space and then measuring the signal at each stationary position. This step-scanning method can be time-consuming, and may induce vibrations in the measurement system when the motors are accelerated and decelerated at each position. Furthermore, diffraction information between the data points may be missed unless a fine step-scanning is used, which further increases the total measurement time.

View Article and Find Full Text PDF

Screen-printing provides an economically attractive means for making Ag electrical contacts to Si solar cells, but the use of Ag substantiates a significant manufacturing cost, and the glass frit used in the paste to enable contact formation contains Pb. To achieve optimal electrical performance and to develop pastes with alternative, abundant and non-toxic materials, a better understanding the contact formation process during firing is required. Here, we use in situ X-ray diffraction during firing to reveal the reaction sequence.

View Article and Find Full Text PDF

Rapid thermal processing (RTP) is widely used for processing a variety of materials, including electronics and photovoltaics. Presently, optimization of RTP is done primarily based on ex-situ studies. As a consequence, the precise reaction pathways and phase progression during the RTP remain unclear.

View Article and Find Full Text PDF

Discovery of new materials drives the deployment of new technologies. Complex technological requirements demand precisely tailored material functionalities, and materials scientists are driven to search for these new materials in compositionally complex and often non-equilibrium spaces containing three, four or more elements. The phase behavior of these high-order composition spaces is mostly unknown and unexplored.

View Article and Find Full Text PDF

The crystal structure of thin films grown by atomic layer deposition (ALD) will determine important performance properties such as conductivity, breakdown voltage, and catalytic activity. We report the design of an atomic layer deposition chamber for in situ x-ray analysis that can be used to monitor changes to the crystal structural during ALD. The application of the chamber is demonstrated for Pt ALD on amorphous SiO2 and SrTiO3 (001) using synchrotron-based high resolution x-ray diffraction, grazing incidence x-ray diffraction, and grazing incidence small angle scattering.

View Article and Find Full Text PDF

Transmission X-ray microscopy has been used to investigate individual Co/TiO2 Fischer-Tropsch (FT) catalyst particles in 2-D and 3-D with 30 nm spatial resolution. Tomographic elemental mapping showed that Co is heterogeneously concentrated in the centre of the catalyst particles. In addition, it was found that Co is mostly metallic during FT at 250 °C and 10 bar.

View Article and Find Full Text PDF

Objective: In April 2005, the US Food and Drug Administration issued a public health advisory warning to health care clinicians about the cardiovascular (CV) safety of nonsteroidal anti-inflammatory drugs (NSAIDs). Although the warning about cyclooxygenase-2 selective NSAIDs was anticipated, little data exists about the CV safety of nonselective NSAIDs. We analyzed data from a group of NSAID users to determine if specific nonselective agents were associated with an increased risk of myocardial infarctions (MIs) and sudden cardiac death (SCD).

View Article and Find Full Text PDF

Objective: To evaluate the safety and effectiveness of a simvastatin-to-lovastatin therapeutic conversion program.

Study Design: Observational database study of a therapeutic conversion in members of the Northern and Southern California regions of Kaiser Permanente, using a pretest/posttest design.

Methods: All patients actively converted from simvastatin to lovastatin between April 1, 2002, and March 31, 2003, were identified for inclusion in the analysis.

View Article and Find Full Text PDF

Background: Controversy has surrounded the question about whether high-dose rofecoxib increases or naproxen decreases the risk of serious coronary heart disease. We sought to establish if risk was enhanced with rofecoxib at either high or standard doses compared with remote non-steroidal anti-inflammatory drug (NSAID) use or celecoxib use, because celecoxib was the most common alternative to rofecoxib.

Methods: We used data from Kaiser Permanente in California to assemble a cohort of all patients age 18-84 years treated with a NSAID between Jan 1, 1999, and Dec 31, 2001, within which we did a nested case-control study.

View Article and Find Full Text PDF

Objective: To investigate the degree to which physicians use clinical factors to focus use of Cox-2 selective NSAIDs within an arthritis population.

Methods: Diagnostic codes in the medical records of a large group-model HMO in northern California with approximately 3 million members were examined to identify patients with either rheumatoid arthritis (RA) or non-RA (osteoarthritis or degenerative joint disease). RA and non-RA patients were stratified in deciles of relative risk for gastrointestinal (GI) complications according to patient characteristics identified on the Standardized Calculator of Risk for Events (SCORE) that were associated with use of Cox-2 selective NSAIDs.

View Article and Find Full Text PDF

Quinacrine has been used for voluntary female non-surgical sterilization for its ability to produce tubal occlusion. Safety issues regarding quinacrine have been raised because it has been shown to intercalate with DNA. Therefore, safety issues need to be resolved by appropriate toxicology studies to support a review for human transcervical use.

View Article and Find Full Text PDF

The aim of this work is to reproduce the experimentally measured linear dependence of cardiac muscle oxygen consumption on stress-strain area using a model, composed of a three-state Huxley-type model for cross-bridge interaction and a phenomenological model of Ca2+-induced activation. By selecting particular cross-bridge cycling rate constants and modifying the cross-bridge activation model, we replicated the linear dependence between oxygen consumption and stress-strain area together with other important mechanical properties of cardiac muscle such as developed stress dependence on the sarcomere length and force-velocity relationship. The model predicts that (1) the amount of the "passenger" cross bridges, i.

View Article and Find Full Text PDF

The strain of muscle fibers in the heart is likely to be distributed uniformly over the cardiac walls during the ejection period of the cardiac cycle. Mathematical models of left ventricular (LV) wall mechanics have shown that the distribution of fiber strain during ejection is sensitive to the orientation of muscle fibers in the wall. In the present study, we tested the hypothesis that fiber orientation in the LV wall is such that fiber strain during ejection is as homogeneous as possible.

View Article and Find Full Text PDF

We have applied an in vitro digestion/Caco-2 cell culture model to the assessment of iron availability from human milk and a generic cow's milk-based infant formula. Experiments were designed to determine the availability of iron from human milk relative to infant formula and whether known promoters of iron absorption would increase Caco-2 cell iron uptake and availability from the infant formula. In addition, we sought to determine if decreasing the citrate concentration in the infant formula would increase the iron uptake.

View Article and Find Full Text PDF

Mathematical models of left ventricular (LV) wall mechanics show that fiber stress depends heavily on the choice of muscle fiber orientation in the wall. This finding brought us to the hypothesis that fiber orientation may be such that mechanical load in the wall is homogeneous. Aim of this study was to use the hypothesis to compute a distribution of fiber orientation within the wall.

View Article and Find Full Text PDF