Patient-specific implant placement in the case of pelvic tumour resection is usually a complex procedure, where the planned optimal position of the prosthesis may differ from the final location. This discrepancy arises from incorrect or differently executed bone resection and improper final positioning of the prosthesis. In order to overcome such mismatch, a navigation solution is presented based on an augmented reality application for HoloLens 2 to assist the entire procedure.
View Article and Find Full Text PDFRev Esp Cir Ortop Traumatol
November 2024
Background And Objectives: 3D-printed patient-specific instruments (PSIs), also known as 3D guides, have been shown to improve accuracy in resection of pelvic tumors in cadaver studies and achieve better surgical margins in vivo. This study evaluates the clinical impact of 3D-printed guides on medium-term local and distant disease control, as well as disease-free and overall survival in patients.
Material And Methods: A cohort study included 25 patients with primary pelvic or sacral sarcomas: 10 in the 3D group and 15 in the control group, with a median follow-up of 47 months.
Background And Objectives: 3D-printed patient-specific instruments (PSIs), also known as 3D guides, have been shown to improve accuracy in resection of pelvic tumors in cadaver studies and achieve better surgical margins in vivo. This study evaluates the clinical impact of 3D-printed guides on medium-term local and distant disease control, as well as disease-free and overall survival in patients.
Material And Methods: A cohort study included 25 patients with primary pelvic or sacral sarcomas: 10 in the 3D group and 15 in the control group, with a median follow-up of 47 months.
The number of elderly patients diagnosed with cancer is increasing. However, knowledge regarding cancer in elderly patients is very scarce. The aim of this study is to analyze the differences in management and outcomes of high-grade extremity sarcomas between elderly and middle-aged patients.
View Article and Find Full Text PDFClin Biomech (Bristol)
January 2024
Introduction: Pelvic ring tumours pose a challenge due to the difficulty in obtaining adequate surgical margins. Tools such as surgical navigation or 3D printing for the fabrication of patient-specific surgical positioning templates help in preoperative planning and intraoperative execution. Their correct positioning is essential in complex locations such as the pelvis, so it is necessary to identify positioning errors.
View Article and Find Full Text PDFThis work analyzed the use of Microsoft HoloLens 2 in orthopedic oncological surgeries and compares it to its predecessor (Microsoft HoloLens 1). Specifically, we developed two equivalent applications, one for each device, and evaluated the augmented reality (AR) projection accuracy in an experimental scenario using phantoms based on two patients. We achieved automatic registration between virtual and real worlds using patient-specific surgical guides on each phantom.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
October 2022
Introduction: The correct positioning of the implant in revision total hip arthroplasty (rTHA) is critical to obtaining substantial functional outcomes, and to avoiding complications. Current literature supports three-dimensional (3D)-printed models as potentially useful tools for preplanning, as well as the "do it yourself (DIY)" methodology to reduce both the time and costs of this procedure. However, no study has determined the efficacy of both methods combined in a cohort of patients with severe acetabular defects.
View Article and Find Full Text PDFPatient-specific instruments (PSIs) have become a valuable tool for osteotomy guidance in complex surgical scenarios such as pelvic tumor resection. They provide similar accuracy to surgical navigation systems but are generally more convenient and faster. However, their correct placement can become challenging in some anatomical regions, and it cannot be verified objectively during the intervention.
View Article and Find Full Text PDFRev Esp Cir Ortop Traumatol
August 2021
Introduction: Pelvic ring tumors pose a challenge due to the difficulty in obtaining adequate surgical margins. Tools such as surgical navigation or 3D printing for the fabrication of patient-specific surgical positioning templates help in preoperative planning and intraoperative execution. Their correct positioning is essential in complex locations such as the pelvis, so it is necessary to identify positioning errors.
View Article and Find Full Text PDFBackground: The integration of 3D printing technology in hospitals is evolving toward production models such as point-of-care manufacturing. This study aims to present the results of the integration of 3D printing technology in a manufacturing university hospital.
Methods: Observational, descriptive, retrospective, and monocentric study of 907 instances of 3D printing from November 2015 to March 2020.
Background: 3D printing technology in hospitals facilitates production models such as point-of-care manufacturing. Orthopedic Surgery and Traumatology is the specialty that can most benefit from the advantages of these tools. The purpose of this study is to present the results of the integration of 3D printing technology in a Department of Orthopedic Surgery and Traumatology and to identify the productive model of the point-of-care manufacturing as a paradigm of personalized medicine.
View Article and Find Full Text PDFDuring the last decade, orthopedic oncology has experienced the benefits of computerized medical imaging to reduce human dependency, improving accuracy and clinical outcomes. However, traditional surgical navigation systems do not always adapt properly to this kind of interventions. Augmented reality (AR) and three-dimensional (3D) printing are technologies lately introduced in the surgical environment with promising results.
View Article and Find Full Text PDFPurpose: 3D-printed patient-specific instruments have become a useful tool to improve accuracy in pelvic tumour resections. However, their correct placement can be challenging in some regions due to the morphology of the bone, so it is essential to be aware of the possible placement errors in each region. In this study, we characterize these errors in common pelvic osteotomies.
View Article and Find Full Text PDFRev Esp Cir Ortop Traumatol (Engl Ed)
October 2021
3D printing (I3D) is an additive manufacturing technology with a growing interest in medicine and especially in the specialty of orthopaedic surgery and traumatology. There are numerous applications that add value to the personalised treatment of patients: advanced preoperative planning, surgeries with specific tools for each patient, customised orthotic treatments, personalised implants or prostheses and innovative development in the field of bone and cartilage tissue engineering. This paper provides an update on the role that the orthopaedic surgeon and traumatologist plays as a user and prescriber of this technology and a review of the stages required for the correct integration of I3D into the hospital care flow, from the necessary resources to the current legal recommendations.
View Article and Find Full Text PDFThe real degree of constriction of rotating hinge knee (RHK) and condylar constrained prostheses (CCK) is a matter of discussion in revision knee arthroplasty. The objectives of this study are to compare the tibial rotation of both implants and validate the use of inertial sensors with optical tracking system as movement measurement tools. A total of 16 cadaver knees were used.
View Article and Find Full Text PDFAugmented reality (AR) has great potential in education, training, and surgical guidance in the medical field. Its combination with three-dimensional (3D) printing (3DP) opens new possibilities in clinical applications. Although these technologies have grown exponentially in recent years, their adoption by physicians is still limited, since they require extensive knowledge of engineering and software development.
View Article and Find Full Text PDFIn intraoperative electron radiation therapy (IOERT) the energy of the electron beam is selected under the conventional assumption of water-equivalent tissues at the applicator end. However, the treatment field can deviate from the theoretic flat irradiation surface, thus altering dose profiles. This patient-based study explored the feasibility of acquiring intraoperative computed tomography (CT) studies for calculating three-dimensional dose distributions with two factors not included in the conventional assumption, namely the air gap from the applicator end to the irradiation surface and tissue heterogeneity.
View Article and Find Full Text PDFCraniosynostosis must often be corrected using surgery, by which the affected bone tissue is remodeled. Nowadays, surgical reconstruction relies mostly on the subjective judgement of the surgeon to best restore normal skull shape, since remodeled bone is manually placed and fixed. Slight variations can compromise the cosmetic outcome.
View Article and Find Full Text PDFRev Esp Cir Ortop Traumatol (Engl Ed)
December 2019
Background: The management of complete bone defects in hip and knee periprosthetic infection is still a real surgical challenge.
Material And Methods: We present a technical modification for performing a biarticular total femoral spacer with a femoral nail without the need to approach the proximal tibia.
Results: Three patients were operated with this technique.