Background: The Centers for Medicare and Medicaid Services (CMS) developed the Severe Sepsis and Septic Shock Performance Measure bundle (SEP-1) metric to improve sepsis care, but evidence supporting this bundle is limited and harms secondary to compliance have not been investigated.
Objective: This study investigates the effect of an emergency department (ED) sepsis quality-improvement (QI) effort to improve CMS SEP-1 compliance, looking specifically at antibiotic overtreatment and harm from fluid resuscitation.
Methods: This was a retrospective observational study conducted between March and July 2021 with patients for whom a sepsis order set was initiated.
Objectives: Immediate recognition of out-of-hospital cardiac arrest (OHCA) by Emergency Medical Dispatch (EMD) operators is crucial to facilitate timely initiation of telephone cardiopulmonary resuscitation (T-CPR) and to enable the appropriate level of Emergency Medical Services (EMS) response. The goal of this study was to identify patterns that can increase EMD-level recognition of cardiac arrests prior to EMS arrival.
Methods: The Combined Communications Center in Alachua County, Florida provided audio recordings of all emergency calls from January 1, 2018 to November 16, 2018 dispatched as a chief complaint other than OHCA, but later identified as cardiac arrest.