Publications by authors named "Cairu Wang"

Objective: To evaluate the feasibility and accuracy of virtual preoperative planning and 3D-printed templates for pre-contoured plates for the treatment of posterior wall fractures of the acetabulum.

Methods: A retrospective analysis of 29 patients with posterior acetabular wall fractures treated between August 2017 and March 2021 were divided into 2 groups based on whether to use preoperative virtual planning and 3D printed template. In 3D-printing group, there were 14 patients, including 10 males and 4 females; aged from 21 to 53 years old;CT-based virtual surgical planning was done using Mimics and 3-Matic software and 3D-printed templates for pre-contoured plates were adopted.

View Article and Find Full Text PDF

Purpose: The comparison of bone ingrowth between two types of porous titanium alloy rods with different micro-architectures including diamond crystal lattice (Re-rod) and biogenic lamellar configurations (Bi-rod) on femoral condyles was investigated in this study.

Methods: Twelve rabbits were used. Re-rod (Re-rod group) and Bi-rod (Bi-rod group) were implanted randomly in femoral condyles of each rabbits respectively.

View Article and Find Full Text PDF

Background: Chemoattractant is critical to recruitment of osteoclast precursors and stimulates tumor bone metastasis. However, the role of chemoattractant in bone metastasis of colorectal cancer (CRC) is still unclear.

Methods: Histochemistry analysis and TRAP staining were utilized to detect the bone resorption and activation of osteoclasts (OCs) after administration of CCL7 neutralizing antibody or CCR1 siRNA.

View Article and Find Full Text PDF

Purpose: This study investigated the ability of liquid nitrogen cryo-insults to induce early-stage osteonecrosis of the femoral head (ONFH) in small tail Han sheep.

Methods: 16 animals were subjected to unilateral cryo-insult using cryogen equipment with a cryo-insult probe, followed 1, 3, and 6 months later by X-ray, CT scanning, micro-CT scanning, and histological evaluation.

Results: X-ray evaluation of operative femoral heads (Op-FHs) at each time point showed low density areas under the cartilage surface that paralleled sclerosis belts, and CT scans showed sclerosis and cyst areas in Op-FHs.

View Article and Find Full Text PDF

There is no ideal implant for mechanical strut on early-stage osteonecrosis of the femoral head (ONFH) after core decompression. In this study, a biogenic trabecular porous titanium rod with lamellar configuration was designed and fabricated using selective laser melting technique. Early-stage ONFH of sheep induced by cryo-insult were dealt with core decompression combined with rod insertion (Rod group) and core decompression alone (CD group) after X-ray evaluation was used to assess the necrotic region one months after cryo-intervention.

View Article and Find Full Text PDF

Background: There is a controversy in terms of the efficacy of vitamin D supplementation in improving asthma symptom control. Moreover, whether there is a difference in the treatment effect with respect to baseline vitamin D status remains unknown. This meta-analysis was to assess the correlations of vitamin D status with asthma-related respiratory outcomes.

View Article and Find Full Text PDF

Instruments made of porous titanium alloy and fabricated with a 3D printed technique are increasingly used in experimental and clinical research. To date, however, few studies have assessed their use in early-stage osteonecrosis of the femoral head (ONFH). In this study, porous titanium alloy rods (Ti-Rod) with diamond crystal lattice, fabricated using an electron beam melting (EBM) technique, were implanted into sheep models (n=9) of early-stage ONFH for 6 months.

View Article and Find Full Text PDF

Type 2 diabetes mellitus (T2DM) is a chronic metabolic disease characterized by lack of insulin and high glucose levels. T2DM can cause bone loss and fracture, thus leading to diabetic osteoporosis. Promoting osteogenic differentiation of osteoblasts may effectively treat diabetic osteoporosis.

View Article and Find Full Text PDF

Background: The Western Ontario Rotator Cuff Index (WORC) is a scale designed to evaluate the impact of rotator cuff (RC) disorders on patients' general quality of life. Our study aims to adapt the WORC for Chinese patients and to assess its reliability, validity, and responsiveness in Chinese patients with RC disorders.

Methods: First, we developed the Chinese version of the WORC (C-WORC) in a five-step procedure of translation and cross-cultural adaptation.

View Article and Find Full Text PDF

MicroRNAs (miRNAs) play significant roles in multiple diseases by regulating the expression of their target genes. Type 2 diabetes mellitus (T2DM) is a chronic endocrine and metabolic disease with complex mechanisms. T2DM can result in diabetic osteoporosis (DO), which is characterized by bone loss, decreased bone mineral density and increased bone fractures.

View Article and Find Full Text PDF

Background Context: Polymethylmethacrylate (PMMA) is widely used for pedicle screw augmentation in osteoporosis. Intriguingly, there have been no biomechanical comparisons of the stability of pedicle screws augmented with different volumes of PMMA or studies of the relationship between screw stability and volume of PMMA, especially in different degrees of osteoporosis.

Purpose: The purposes of the study reported here were to compare screw stability by different volumes of PMMA augmentation, to analyze the relationship between screw stability and PMMA volume, and to make a preliminary determination of the optimum volume of PMMA augmentation for different degrees of osteoporosis.

View Article and Find Full Text PDF

This study was designed to compare screw stabilities augmented with different volumes of PMMA and analyze relationship between screw stability and volume of PMMA and optimum volume of PMMA in different bone condition. Osteoporotic and severely osteoporotic synthetic bone blocks were divided into groups A0-A5 and B0-B5, respectively. Different volumes of PMMA were injected in groups A0 to A5 and B0 to B5.

View Article and Find Full Text PDF

Titanium alloys with various porous structures can be fabricated by advanced additive manufacturing techniques, which are attractive for use as scaffolds for bone defect repair. However, modification of the scaffold surfaces, particularly inner surfaces, is critical to improve the osteointegration of these scaffolds. In this study, a biomimetic approach was employed to construct polydopamine-assisted hydroxyapatite coating (HA/pDA) onto porous Ti6Al4V scaffolds fabricated by the electron beam melting method.

View Article and Find Full Text PDF

Study Design: In this study, calcium sulfate (CS) was injected through pedicle into the osteoporotic vertebral body in vivo in sheep, and micro-computed tomography analysis, histologic observation, and biomechanical test were performed.

Objective: To investigate the improvement on microstructure and biomechanical performance of lumbar vertebrae augmented with CS in osteoporotic sheep.

Summary Of Background Data: The present treatments for osteoporosis relies on systemic medications intended to increase the bone mineral density (BMD).

View Article and Find Full Text PDF

Background: It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine.

View Article and Find Full Text PDF

There is no consensus on how to establish models of osteonecrosis of the femoral head (ONFH) in large mammals. The aim of this study was to investigate the effectiveness of a novel canine model of ONFH, induced by a navigated injection of absolute ethanol. Using three-dimensional reconstruction and rapid prototyping manufacturing techniques, a new template was designed and processed to navigate the ethanol injection.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to compare the effectiveness of two types of screws, expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS), for stability in sheep lumbar vertebrae.
  • Sixty sheep vertebrae were tested, where different screws were inserted and evaluated through biomechanical tests, X-rays, and histological exams, showing that both EPS and PMMA-PS provided better stability than conventional screws.
  • Although both EPS and PMMA-PS enhanced screw stability, there was no significant difference between the two, with PMMA forming a barrier that limited direct bone contact, while EPS created a more integrated "screw-bone
View Article and Find Full Text PDF