Purpose: This study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept.

Materials And Methods: Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed.

View Article and Find Full Text PDF

Purpose: This in vitro study compared the adaptation of denture bases fabricated by injection molding (IM), compression molding (CM), liquid crystal display (LCD), and digital light processing (DLP) techniques.

Material And Methods: A definitive maxillary cast was duplicated using a silicone mold to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. For the DLP and LCD groups, 20 denture bases (10 in each group) were virtually designed and manufactured referring to the digitalized data.

View Article and Find Full Text PDF

Purpose: The primary stability of dental implants is one of the most crucial factors for providing long-term success of osseointegration. Vertical deficiencies, such as those due to maxillary sinus pneumatization, may cause a severe vertical limitation to residual bone height. This study aimed to examine the primary stabilization of implants without apical contacts.

View Article and Find Full Text PDF

The aim of this study was to examine the primary stabilization of different vertically impacted bone implants. Implant stability was measured by resonance frequency analysis. Forty-five dental implants were used and divided into 3 groups.

View Article and Find Full Text PDF

Statement Of Problem: Digital scanning systems have become popular, but whether these systems are adequate for complete-arch implant-supported fixed dental prostheses is unclear.

Purpose: The purpose of this in vitro study was to evaluate the trueness of 10 different dental intraoral scanners.

Material And Methods: Six implant analogs were installed, and an edentulous mandibular model composed of scannable Type 4 gypsum was scanned with 10 different intraoral scanners (3D Progress, Omnicam, Bluecam, Apollo DI, Planscan, E4D Tech, TRIOS MonoColor Cart, TRIOS Color Cart, TRIOS Color Pod, Lythos), 10 times each after the scan body was placed on the implant abutments.

View Article and Find Full Text PDF

Objectives: Both direct and indirect techniques are used for composite resin material (CRM) restorations. Polishing processes are needed in both techniques after intraoral adjustment. However, it is unclear as to which polishing technique should be preferred with respect to decreasing biofilm.

View Article and Find Full Text PDF

Purpose: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone.

Materials And Methods: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively.

View Article and Find Full Text PDF

The aim of this study was to find an optimal value for tightening the Smartpegs for magnetic radiofrequency analysis devices (RFAs) devices. Thirty implants were placed in 3 cow ribs. The RFA value of each implant was measured in buccal and mesial directions after tightening the Smartpegs with 1, 3, 4, 8, 9, 10, and 11 Ncm.

View Article and Find Full Text PDF

This study evaluates the influence of interimplant distance (ID) on patient satisfaction and quality of life (QOL) of 55 patients who received mandibular overdentures supported by two implants. IDs were measured over the residual ridge crest and linearly on all of the patients' mandibular casts. The crestal detours of all patients were determined by subtracting these two values from each other.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers.

Materials And Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments.

View Article and Find Full Text PDF

Background: A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device.

Methods: Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.

View Article and Find Full Text PDF

Periotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs.

View Article and Find Full Text PDF

The aim of this clinical study was to evaluate the prosthodontic maintenance requirements during the first year of service of mandibular overdentures supported by interforaminal implants and to assess the influence of attachment type, implant number, and bite force on these requirements. Fifty-nine patients treated with mandibular implant overdentures between the years 2004 and 2009 and appearing in the 12th-month recall were included in this study. The overdentures constituted 4 groups: 2 single interforaminal implants (1 group with locator and 1 group with ball attachments), 3 single interforaminal implants, 3 splinted interforaminal implants (bar), and 4 splinted interforaminal implants (bar).

View Article and Find Full Text PDF