Publications by authors named "Caes F"

Objectives: Concerns have been raised about the durability of the first-generation Mitroflow aortic bioprosthesis (model 12 A-LX) due to the lack of anticalcification treatment. This study reflects a 10-year experience with this prosthesis for aortic valve replacement.

Methods: From June 2003 to May 2012, the Mitroflow prosthesis was used for aortic valve replacement in 510 patients, of whom only 467 with complete clinical follow-up were included for analysis.

View Article and Find Full Text PDF

Objectives: To investigate the long-term results of a low international normalized ratio (INR)-anticoagulation program in selected patients after aortic valve replacement (AVR) with the Medtronic Open Pivot mechanical heart valve (OPMHV).

Methods: From January 1993 to December 2012, 909 OPMHV valves were used for single AVR. Patients with preserved sinus rhythm and left ventricular function (Low-INR, n  = 552), were managed to an INR of 1.

View Article and Find Full Text PDF

Significant mitral valve disease with atrial fibrillation after heart transplantation is unusual. We report the diagnosis and minimally invasive surgical treatment 17 years after transplantation, in which mitral valve repair together with left atrial ablation was performed, resulting in a satisfying clinical and echocardiographic improvement.

View Article and Find Full Text PDF

Background: Since May 1992 the Medtronic Open Pivot mechanical heart valve has been implanted routinely at the authors' institution. The study aim was to analyze, retrospectively, the 20-year clinical results of the valve.

Methods: Between May 1992 and December 2011 a total of 1,520 valves was inserted into 1,382 consecutive patients (1,012 aortic, 473 mitral, 26 tricuspid, 9 pulmonary).

View Article and Find Full Text PDF

Objectives: We studied a contemporary cohort of adult patients treated surgically for infective endocarditis (IE) in order to evaluate the surgical approach and predictors of outcomes, in relation to the intercurrent adaptation of the 2006 ACC/AHA guidelines.

Methods: One hundred and eighty-six consecutive patients operated on for active IE from August 1999 to September 2012 were reviewed retrospectively. Clinical presentation, surgical management and outcomes in the two study periods before and after January 2007 were compared (Period 1: n = 95 and Period 2: n = 91).

View Article and Find Full Text PDF

Background And Aim Of The Study: Since January 1990, a variety of mechanical valves (St. Jude Medical, CarboMedics, ATS Medical) have been implanted routinely at the authors' institution. The study aim was to analyze, retrospectively, the 20-year clinical results of those mechanical valves, and to challenge the anticoagulation policy employed over the years.

View Article and Find Full Text PDF

Objective: To report a case of fatal alveolar hemorrhage associated with the use of everolimus in a patient who underwent a solid organ transplant.

Case Summary: In a 71-year-old cardiac transplant patient, cyclosporine was replaced with everolimus because of worsening renal function. Over the following weeks, the patient developed nonproductive cough and increasing dyspnea.

View Article and Find Full Text PDF

Objectives: The objective of this study was to investigate the patient characteristics and outcomes in 1406 patients undergoing intra-aortic balloon pump (IABP) counterpulsation.

Methods: Between 1998 and 2008, 1406 consecutive patients were recorded in a prospective database. Based on the main clinical indication for IABP use, we defined 3 groups: group A, 630 cases of coronary ischaemia or infarction without serious left ventricular (LV) dysfunction; group B, 466 patients with left ventricular failure or cardiogenic shock; group C, 310 patients where IABP was used for miscellaneous procedures such as weaning from cardiopulmonary bypass or during high-risk angioplasty or surgery.

View Article and Find Full Text PDF

Background And Aim Of The Study: Since its introduction in May 1992, the bileaflet ATS Open Pivot valve has been implanted routinely at the authors' institution. The study aim was to analyze, retrospectively, the 15-year clinical results of these implanted ATS valves.

Methods: Between May 1992 and December 2005, a total of 1,160 ATS valves (749 aortic, 381 mitral, 21 tricuspid, nine pulmonary) was implanted in 1,047 consecutive patients (655 males, 392 females; mean age 62.

View Article and Find Full Text PDF

Objective: Based on the adverse relationship between left ventricular (LV) remodeling and clinical outcome in ischemic cardiomyopathy, surgical ventricular restoration (SVR) is proposed as a valuable adjunct procedure. This study reports on the short-term clinical and hemodynamical performance of SVR.

Methods: Using end-systolic LV volume as indication for SVR, 78 patients with ischemic cardiomyopathy are divided in two groups: group 1 comprised 55 patients treated by coronary revascularization and mitral annuloplasty, group 2 comprised 23 patients undergoing additional SVR.

View Article and Find Full Text PDF

Objective: To report on the midterm results of aortic valve replacement (AVR) with stented and stentless bioprosthesis in an elderly population by analyzing the factors affecting survival and hemodynamical performance.

Methods: In a retrospective study, 145 patients with a Toronto stentless prosthesis are compared with 110 patients with a stented Carpentier-Edwards valve. The 5- to 10-year clinical outcome, transprosthetic gradients, and early and late left ventricular mass (LVM) regression are analyzed in view of specific prosthesis- and patient-related factors.

View Article and Find Full Text PDF

Background: The design of the bileaflet ATS (ATS Medical Inc., Minneapolis, USA) mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of the blood at the pivot area was observed using 3-D computational fluid dynamics modelling.

View Article and Find Full Text PDF

A retrospective assessment of clinical and echocardiographic variables was performed in 145 patients who received a Toronto SPV aortic valve replacement. The majority (90%) of these elderly patients (mean age, 75.5 +/- 7.

View Article and Find Full Text PDF

Background: to determine the advantages and/or risks of minimal access aortic valve replacement compared to standard sternotomy procedure.

Methods: from January 1997 to December 2001, 271 consecutive adult patients underwent isolated aortic valve replacement of which 174 underwent a minimal access procedure (Group 1) and 97 a standard procedure (Group 2). The preoperative variables of both groups were comparable.

View Article and Find Full Text PDF

Background And Aim Of The Study: The design of the bileaflet ATS mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of blood at the pivot area seen using three-dimensional computational fluid dynamics modeling may make the valve less vulnerable for clot formation in patients without major thromboembolic risk factors.

Methods: Between January 1993 and June 1999, the ATS valve was implanted in the aortic position in 286 consecutive patients.

View Article and Find Full Text PDF

Objective: The aim of the study is to explore the feasibility and mid-term patency of an easier anastomotic technique for Minimally Invasive Direct Coronary Bypass Grafting (MIDCAB).

Methods: Eight mongrel dogs (+/-15 kg) underwent direct anastomosis between the left internal thoracic artery (LITA) and the left anterior descending coronary artery (LAD) via inferior sternotomy on the beating heart. After positioning the graft, the distal part of the LAD was opened to allow retrograde filling of the LITA-graft.

View Article and Find Full Text PDF

Objective: In a retrospective study, we compared two groups of consecutive patients operated by the same team during the year 2000 for coronary artery disease with the use of extracorporeal circulation (group 1, n=230) or on the beating heart using the Octopus II plus stabiliser (group 2, n=228). High-risk patients were identified by a EuroSCORE plus 6. EuroSCORE definitions and predicted risk models were utilized to compare the variables of the groups.

View Article and Find Full Text PDF

Objective: To compare the effects of cardiac surgery with and without extracorporeal circulation on the mechanics of the respiratory system, lung, and chest wall. We also determined the time course of those effects.

Design: Prospective, controlled study.

View Article and Find Full Text PDF

Objective: This study investigates the influence of foreign material and blood aspirated from nonvascular structures on activation of coagulation, hemolysis, and blood loss.

Methods: The series comprises 3 randomized groups (groups C, S, and S+P) of 10 patients undergoing routine coronary artery bypass grafting with cardiopulmonary bypass. In group C, the control group, all aspirated blood was returned into the circulation.

View Article and Find Full Text PDF

Return of blood activated by tissue factor is the main culprit for triggering the coagulation cascade. When this activated blood is diverted from the cardiopulmonary bypass (CPB) circuit, it becomes possible to evaluate the effect of surface treatment on platelet and complement activation. Twenty adult patients undergoing elective coronary artery bypass grafting (CABG) were randomly assigned either to a control group (n=10) or to a group in which the CPB circuit was completely coated with phosphorylcholine (n=10).

View Article and Find Full Text PDF

Background: Redo-CABG surgery remains extremely hazardous in the presence of open bypass grafts. In our patients with mitral valve pathology with open and well-functioning bypass grafts, we explored alternative approaches in order to avoid damage to the grafts by extensive dissection and direct clamping of the ascending aorta. The "Estech procedure," which uses the Estech remote access perfusion (RAP) endoclamp catheter (Estech Inc.

View Article and Find Full Text PDF

Background: Our study evaluated the efficacy and feasibility of a pumpless respiratory assist device and determined its capacity for carbon dioxide removal.

Methods: In five adult pigs the left femoral vein and artery were cannulated with a 20F cannula and connected to a low-pressure hollow-fiber artificial lung. After we had obtained baseline values of mean arterial pressure, cardiac output, and blood flow across the artificial lung, the mean arterial pressure was reduced 20% and 40% relative to baseline; in a second phase, it was raised 20% and 40.

View Article and Find Full Text PDF

Objective: To assess differences in indication and mid-term results between stentless and stented procedures in elderly patients, we followed aortic valve patients over a period of 5 years.

Methods: In a consecutive series of 154 elderly aortic patients in regular sinus rhythm from 1992 to 1997, we inserted 103 stentless (Toronto SPVTM, St Jude Medical Inc., St Paul, Minneapolis, MN) and 51 stented (Carpentier-Edwards supra annular porcine, Baxter Inc.

View Article and Find Full Text PDF

Two members of a family with (autosomal dominant) dilated cardiomyopathy and symptomatic short-lasting ventricular tachyarrhythmias were each treated with an ICD in the course of their disease. One patient had an episode of torsades de pointes induced by amiodarone, and the ICD failed to recognize some events. Cardiac arrest recurred in this setting.

View Article and Find Full Text PDF

Between May 1992 and March 1994, 100 consecutive patients had 119 new ATS mechanical bileaflet valves inserted (61 aortic, 50 mitral, eight tricuspid). The mean age of the patients was 63.7 (range 13-82) years.

View Article and Find Full Text PDF