Publications by authors named "Cabot F"

Purpose: To determine whether patient-customized paraxial eye models that do not rely on exact ray tracing and do not consider aberrations can accurately predict pseudophakic refraction.

Setting: Bascom Palmer Eye Institute, Miami, Florida.

Design: Prospective study.

View Article and Find Full Text PDF

We have combined an anterior segment (AS) optical coherence tomography (OCT) system and a wavefront-based aberrometer with an approach that senses ocular wavefront aberrations using the OCT beam. Temporal interlacing of the OCT and aberrometer channels allows for OCT images and refractive error measurements to be acquired continuously and in real-time. The system measures refractive error with accuracy and precision comparable to that of clinical autorefractors.

View Article and Find Full Text PDF
Article Synopsis
  • * The average attenuation coefficient for the sclera was 4.13 ± 1.42 mm, showing a slight decline with age (p = 0.053), while the ciliary muscle's coefficient was averaged at 1.72 ± 0.88 mm, potentially underestimated due to multiple scattering.
  • * Variations in scleral attenuation could affect the quality of transscleral OCT images and the effectiveness of transscleral laser therapies.
View Article and Find Full Text PDF

Purpose: To present a rare presentation of pyogenic granuloma arising almost 4 decades after a scleral buckle for retinal detachment.

Method: We describe the clinical presentation, diagnostic workup, and management of a suspicious conjunctival lesion in an immunocompromised patient. We report the histopathological findings and the postoperative outcome.

View Article and Find Full Text PDF

The lens equivalent refractive index (RI) is commonly used in calculations of crystalline lens power. However, accurate determination of the equivalent RI is challenging due to the need of multiple measurements with different ocular biometry devices. A custom extended-depth Spectral Domain-OCT system was utilized to provide measurements of corneal and lens surface curvatures and all intraocular distances required for determination of the lens equivalent RI.

View Article and Find Full Text PDF

Purpose: To study outcomes after surgical removal of epithelial ingrowth (EI) in post-laser in situ keratomileusis patients, specifically comparing visual results and recurrence rates between 2 different EI management techniques.

Methods: In this retrospective chart review of 67 eyes of 54 patients who underwent surgical treatment for EI after laser in situ keratomileusis between July 1999 and July 2014 at the Bascom Palmer Eye Institute, Miami, FL, surgical techniques, recurrence rates, visual acuity (VA), and refractive error were assessed.

Results: Of the 67 eyes, 56 eyes (83.

View Article and Find Full Text PDF

Purpose: To assess aqueous humor concentration of prostaglandin E (PGE) after capsulotomy creation using a femtosecond laser (FLAC) in patients pretreated with short-term topical ketorolac versus patients without pretreatment.

Methods: This prospective study comprised consecutive patients scheduled to undergo cataract surgery using a femtosecond laser platform to perform only capsulotomies. An identical protocol for preoperative mydriasis was used for all the eyes included in the study, while aqueous humor was extracted from the anterior chamber of all patients immediately after the initial side port incision.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) offers new options for imaging the ciliary muscle allowing direct visualization. However, variation in image quality along the length of the muscle prevents accurate delineation and quantification of the muscle. Quantitative analyses of the muscle are accompanied by variability in segmentation between examiners and between sessions for the same examiner.

View Article and Find Full Text PDF

It has been suggested that accommodation induces increases in axial eye length which could contribute to the development of myopia. However, it is debated whether changes in eye length occur during accommodation as the degree of change varies widely across literature. In this study, an extended-depth optical coherence tomography (OCT) system that provides dynamic whole eye biometry was utilized to assess changes in lens thickness (LT) and axial eye length (AEL) in young subjects responding to step disaccommodation stimuli of amplitude 2D, 4D, and 6D.

View Article and Find Full Text PDF

The NASA Soil Moisture Active Passive (SMAP) satellite mission was launched on January 31, 2015 to provide global mapping of high-resolution soil moisture and freeze-thaw state every 2-3 days using an L-band (active) radar and an L-band (passive) radiometer. The Level 2 radiometer-only soil moisture product (L2_SM_P) provides soil moisture estimates posted on a 36-km Earth-fixed grid using brightness temperature observations from descending passes. This paper provides the first comparison of the validated-release L2_SM_P product with soil moisture products provided by the Soil Moisture and Ocean Salinity (SMOS), Aquarius, Advanced Scatterometer (ASCAT), and Advanced Microwave Scanning Radiometer 2 (AMSR2) missions.

View Article and Find Full Text PDF

Purpose: To assess pupil diameter before and after femtosecond laser-assisted capsulotomy in patients who were pretreated with a short-term topical nonsteroidal anti-inflammatory drug (NSAID) (ketorolac) versus those without pretreatment.

Methods: This prospective, randomized, observational case series included consecutive patients scheduled to undergo cataract extraction using the Catalys femtosecond laser platform (Abbott Medical Optics, Inc., Santa Ana, CA) to perform only capsulotomies.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of femtosecond laser-assisted (FA) tunnel creation as a pretreatment for creating a big bubble (BB) to pneumo-dissect the corneal stroma from Descemet membrane.

Methods: Five human cadaver eyes received pretreatment using a femtosecond laser. An intrastromal tunnel, along with a side cut, was achieved using customized femtosecond corneal disruption (custom mask).

View Article and Find Full Text PDF

Two SD-OCT systems and a dual channel accommodation target were combined and precisely synchronized to simultaneously image the anterior segment and the ciliary muscle during dynamic accommodation. The imaging system simultaneously generates two synchronized OCT image sequences of the anterior segment and ciliary muscle with an imaging speed of 13 frames per second. The system was used to acquire OCT image sequences of a non-presbyopic and a pre-presbyopic subject accommodating in response to step changes in vergence.

View Article and Find Full Text PDF

Purpose: To develop a nomogram for femtosecond laser astigmatic keratotomy (AK) to treat post-keratoplasty astigmatism.

Setting: Three academic medical centers.

Design: Retrospective interventional case series.

View Article and Find Full Text PDF

Purpose: To assess pupil diameter before and after femtosecond laser-assisted cataract surgery (FLACS) pretreatment and compare the outcomes of three laser platforms.

Methods: This prospective observational case series included consecutive patients scheduled to undergo cataract extraction using FLACS between August 2013 and February 2015. All eyes received FLACS pretreatment using three laser platforms: LenSx (Alcon Laboratories, Inc.

View Article and Find Full Text PDF

Purpose: To assess the surgically induced corneal astigmatism (SIA) introduced by femtosecond laser-assisted clear corneal incisions (CCIs) for cataract extraction and to compare it with the SIA of manually created CCIs.

Setting: Bascom Palmer Eye Institute, Miller School of Medicine, Miami, Florida, USA.

Design: Prospective nonrandomized comparative case series.

View Article and Find Full Text PDF

Purpose: To compare capsulotomy outcomes between two femtosecond laser platforms for cataract surgery.

Methods: This retrospective case series included 205 eyes of 162 consecutive patients (75 male and 87 female) aged 68.32 ± 10.

View Article and Find Full Text PDF

We present a method for measuring lens power from extended depth OCT biometry, corneal topography, and refraction using an improvement on the Bennett method. A reduced eye model was used to derive a formula for lens power in terms of ocular distances, corneal power, and objective spherical equivalent refraction. An error analysis shows that the formula predicts relaxed lens power with a theoretical accuracy of ± 0.

View Article and Find Full Text PDF

Purpose: To assess the causes for intrastromal corneal ring segment (Intacs; Addition Technology Inc., Lombard, IL) explantation in patients with keratoconus, and technique for explantation, long-term outcomes, and secondary procedures to correct visual acuity.

Methods: Ten eyes of 8 patients with a history of Intacs explantation between 2004 and 2012 were included in a retrospective study performed at the Bascom Palmer Eye Institute, Miami, Florida.

View Article and Find Full Text PDF

A 26-year-old woman presented with signs and symptoms of acute angle-closure glaucoma (ACG) in her left eye. Extended-depth spectral-domain optical coherence tomography (SD-OCT) was performed to biometrically assess the anterior chamber depth and crystalline lens conformation. Extended-depth SD-OCT imaging of the crystalline lens showed bilateral spherophakia without dislocation.

View Article and Find Full Text PDF

Purpose: To assess if a change in refractive index of the anterior chamber during femtosecond laser-assisted cataract surgery can affect the laser beam focus position.

Methods: The index of refraction and chromatic dispersion of six ophthalmic viscoelastic devices (OVDs) was measured with an Abbe refractometer. Using the Gullstrand eye model, the index values were used to predict the error in the depth of a femtosecond laser cut when the anterior chamber is filled with OVD.

View Article and Find Full Text PDF