Publications by authors named "C-J Jakobsen"

Article Synopsis
  • Out-of-hospital cardiac arrest is a major global health issue, necessitating effective vascular access for drug administration during resuscitation.
  • A clinical trial comparing intraosseous and intravenous methods found that both had similar effectiveness for restoring circulation, with around 30% of patients in each group succeeding.
  • At 30 days post-arrest, survival rates and favorable neurologic outcomes also showed no significant differences between the two methods, indicating both approaches are equally viable.
View Article and Find Full Text PDF
Article Synopsis
  • Decisions to implant an ICD in children are complex due to factors like their longer lifespan and higher risk of complications, but they often benefit the most from such devices.
  • This study reviewed data from pediatric patients (≤ 15 years) in Denmark who received ICDs from 1982 to 2021, focusing on their demographics, complications, and mortality outcomes.
  • Results showed no significant differences in outcomes between primary and secondary prevention ICDs, with a notable 41% complication rate and a 10-year appropriate therapy incidence of 70%, indicating that children have higher therapy and complication rates than adults.
View Article and Find Full Text PDF

The fraction of χ_{c1} and χ_{c2} decays in the prompt J/ψ yield, F_{χ_{c}→J/ψ}=σ_{χ_{c}→J/ψ}/σ_{J/ψ}, is measured by the LHCb detector in pPb collisions at sqrt[s_{NN}]=8.16  TeV. The study covers the forward (1.

View Article and Find Full Text PDF

Background: The use of cerebral oximetry monitoring in the care of extremely preterm infants is increasing. However, evidence that its use improves clinical outcomes is lacking.

Methods: In this randomized, phase 3 trial conducted at 70 sites in 17 countries, we assigned extremely preterm infants (gestational age, <28 weeks), within 6 hours after birth, to receive treatment guided by cerebral oximetry monitoring for the first 72 hours after birth or to receive usual care.

View Article and Find Full Text PDF

Background: Biodegradable polymer drug-eluting stents were developed to improve safety and efficacy outcomes for patients undergoing percutaneous coronary intervention. However, few long-term follow-up efficacy studies are available. The study sought to investigate 5-year results from the SORT OUT VII trial (Scandinavian Organization for Randomized Trials With Clinical Outcome) comparing the biodegradable polymer ultrathin-strut sirolimus-eluting Orsiro stent (O-SES) versus the biodegradable polymer biolimus-eluting Nobori stent (N-BES).

View Article and Find Full Text PDF

Anticoagulant therapy is essential in pregnant women with mechanical heart valves to prevent valve thrombosis. The risk of bleeding complications in these patients has not gained much attention. This systematic review and meta-analysis investigate the prevalence of bleeding peri-partum and post-partum in women with mechanical heart valves and also investigate whether bleeding risk differed across anticoagulant regimens or according to delivery mode.

View Article and Find Full Text PDF

The goal of this trial was to investigate whether an eHealth lifestyle coaching programme led to significant weight loss and decreased Haemoglobin A1c (HbA1c) in patients with type 2 diabetes. In an RCT, 170 patients were enrolled from 2018 to 2019 for intervention or control. Inclusion criteria were diagnosed with type 2 diabetes, BMI 30−45 kg/m2, and aged 18−70 years.

View Article and Find Full Text PDF

Background: Targeted temperature management is recommended for patients after cardiac arrest, but the supporting evidence is of low certainty.

Methods: In an open-label trial with blinded assessment of outcomes, we randomly assigned 1900 adults with coma who had had an out-of-hospital cardiac arrest of presumed cardiac or unknown cause to undergo targeted hypothermia at 33°C, followed by controlled rewarming, or targeted normothermia with early treatment of fever (body temperature, ≥37.8°C).

View Article and Find Full Text PDF

Background And Purpose: The computed tomography angiography or contrast-enhanced computed tomography based spot sign has been proposed as a biomarker for identifying on-going hematoma expansion in patients with acute intracerebral hemorrhage. We investigated, if spot-sign positive participants benefit more from tranexamic acid versus placebo as compared to spot-sign negative participants.

Methods: TICH-2 trial (Tranexamic Acid for Hyperacute Primary Intracerebral Haemorrhage) was a randomized, placebo-controlled clinical trial recruiting acutely hospitalized participants with intracerebral hemorrhage within 8 hours after symptom onset.

View Article and Find Full Text PDF

Most type 2 diabetes patients are treated in general practice and there is a need of developing and implementing efficient lifestyle interventions. eHealth interventions have shown to be effective in promoting a healthy lifestyle. The purpose of this study was to test the feasibility, including the identification of factors of importance, when offering digital lifestyle coaching to type 2 diabetes patients in general practice.

View Article and Find Full Text PDF

Background: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population.

View Article and Find Full Text PDF

Background: In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.

Methods: The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial.

View Article and Find Full Text PDF

Background: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients.

View Article and Find Full Text PDF

Background: Inotropes used to obtain short-term hemodynamic benefits in cardiac surgery may carry a risk of increased myocardial ischemia and adverse outcomes. This study investigated the association between intra- and postoperative use of inotropes and mortality and postoperative complications.

Methods: A historic cohort study using prospective data from the Western Denmark Heart Registry on 6,005 consecutive cardiac surgery cases from three university hospitals.

View Article and Find Full Text PDF

MAGE A3, which belongs to the family of cancer-testis antigens, is an attractive target for adoptive therapy given its reactivation in various tumors and limited expression in normal tissues. We developed an affinity-enhanced T cell receptor (TCR) directed to a human leukocyte antigen (HLA)-A*01-restricted MAGE A3 antigen (EVDPIGHLY) for use in adoptive therapy. Extensive preclinical investigations revealed no off-target antigen recognition concerns; nonetheless, administration to patients of T cells expressing the affinity-enhanced MAGE A3 TCR resulted in a serious adverse event (SAE) and fatal toxicity against cardiac tissue.

View Article and Find Full Text PDF