Simple, robust, sensitive and low-cost all-solid-state ion-selective electrodes (SCISEs) are of interest in different fields, such as medicine, veterinary, water treatment, food control, environmental and pollution monitoring, security, etc. as a replacement for traditional ion-selective electrodes with liquid inner contact. In spite of their potential advantages, SCISEs remain mainly in the research laboratories.
View Article and Find Full Text PDFHigh throughput sequencing is discovering many likely causative genetic variants in individuals with cerebral palsy. Some investigators have suggested that this changes the clinical diagnosis of cerebral palsy and that these individuals should be removed from this diagnostic category. Cerebral palsy is a neurodevelopmental disorder diagnosed on clinical signs, not etiology.
View Article and Find Full Text PDFWe report here the fabrication of solid-contact calcium-selective electrodes (Ca-SCISEs) made of a polyurethane acrylate ion-selective membrane (ISM) that was covalently attached to the underlying ion-to-electron transducer (solid-contact). Methacrylate-functionalized poly(3,4-ethylenedioxythiophene) (Meth-PEDOT) and Meth-PEDOT films containing either multiwalled carbon nanotubes (MWCNT) or carboxylated MWCNT (cMWCNT) were used as solid contacts. The solid contacts were deposited by drop-casting on screen-printed electrodes and characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and potentiometry.
View Article and Find Full Text PDFA new solid contact ion selective electrode with intermediate conducting polymer (CP) layer formed by electropolymerization on a gold electrode of a bifunctional monomer, n-phenyl-ethylenediamine-methacrylamide (NPEDMA), which contains a methacrylamide group attached to aniline, is presented. The conducting polymer was studied by means of optical spectroscopy, cyclic voltammetry and potentiometric measurements. Ca-ion-selective membrane based on acrylated urethane polymer was shown to co-polymerize with the CP forming highly adhesive boundary that prevents formation of water layers between the CP and membrane, thus enhancing the stability and life-time of the sensor.
View Article and Find Full Text PDFIn this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal.
View Article and Find Full Text PDF