Background: To explore the feasibility and image quality of ultra-low volume contrast-saline mixture injection with dual-flow injection technique in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI).
Methods: Forty (40) TAVI candidates underwent investigation with CTA using a third-generation dual-source CT scanner between September and November 2020. Different volumes of a monophasic contrast-saline mixture at an 80:20 ratio were administered at an infusion rate of 3 mL/s in 20 patients (group A).
Purpose: To support the wellbeing of both patients and their families, our aim was to investigate the satisfaction of non-COVID in- and out-patients regarding safety measures implemented at our radiology unit of a transplant institute against COVID infection.
Materials And Methods: Over a five-month period, adult patients' feedback was obtained by a questionnaire on the fear of contracting COVID-19 during a radiology examination, the perceived delay in treatment, and the following safety measures implemented: modified schedules to limit the number of patients in the waiting area and to maximize social distancing; assistance by staff when visitors were not admitted; cleaning and disinfection of machines; mask wearing and hand hygiene of staff; and staff advice on hand hygiene and infection control precautions.
Results: Over a five-month period, our preliminary results (387 patients) showed general patient satisfaction (99.
The aim of this work was to establish local diagnostic reference levels (DRLs) for retrograde wedge portography (RWP) performed on pediatric patients assessing the usefulness of radiation dose monitoring software in the establishing process. Between September 2016 and April 2020, 66 consecutive RWP were performed at a transplantation institute and were included in our study. Patients were divided in three groups according to age: n = 25 infants, n = 20 middle childhood and n = 21 early adolescence.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2020
We report three cases of clinically necessary, fluoroscopy-guided, percutaneous biliary procedures performed safely in a pregnant, liver transplant recipient using three different angiography suites. The uterine cumulative equivalent dose was 0.25 mSv, a value obtained by adding the doses of the three procedures described above, and which is relatively low when compared with the naturally occurring background radiation exposure for a 9-month pregnancy (~0.
View Article and Find Full Text PDF