Publications by authors named "C M Cobbaert"

External quality assessment (EQA) enhances patient safety through the evaluation of the quality of laboratory-based and point of care testing. Regulatory agencies and accreditation organizations utilize the results and the laboratory's response to them as part of assessing the laboratory's fitness to practice. In addition, where EQA samples are commutable and the assigned value has been determined using reference measurement procedures (RMPs), EQA data contributes to the verification of metrological traceability of assays as part of the post-market surveillance of diagnostic (IVD) medical devices (IVD-MDs).

View Article and Find Full Text PDF

Providers of external quality assessment (EQA) programs evaluate data or information obtained and reported by participant laboratories using their routine procedures to examine properties or measurands in samples provided for this purpose. EQA samples must offer participants an equal chance to obtain accurate results, while being designed to provide results in clinically relevant ranges. It is the responsibility of the EQA provider to meet the necessary requirements for homogeneity, stability and some other properties of the EQA items in order to offer participants a fair, reliable and technically interesting EQA experience.

View Article and Find Full Text PDF

Aim: Lipoprotein (a) [Lp(a)] is a well-established risk factor for cardiovascular disease independent of low-density lipoprotein-cholesterol (LDL-C). The Lp(a) concentrations were inconsistent between the immunoassays. This study aimed to investigate whether harmonization of Lp(a) measurements can be achieved using a serum panel value assigned with the IFCC-endorsed mass spectrometry-based reference measurement procedure (IFCC-MS-RMP).

View Article and Find Full Text PDF

Objectives: As high-sensitivity cardiac troponin T (hs-cTnT) is making the transition from diagnostic to prognostic use, a long-term stability study of 5th generation hs-cTnT according to EFLM CRESS recommendations was set up for investigation of frozen clinical specimens (two matrices).

Methods: Study samples collected in serum tubes and lithium heparin tubes with gel from patients admitted for suspected minor myocardial damage were measured directly after completion of the study (0 years), and after 3-year and 6-year storage at -80 °C, and recovery of hs-cTnT concentrations after long-term storage (%hs-cTnT concentration compared to 0-year) was calculated. Hs-cTnT changes were also compared to decisive delta changes, such as the ones proposed in the ESC NSTEMI 0 h/1 h algorithm (<3 or >5 ng/L for ruling out and ruling in suspected NSTEMI patients).

View Article and Find Full Text PDF

Objectives: Quantitative protein mass spectrometry (MS) is ideally suited for precision diagnostics and for reference standardization of protein analytes. At the Leiden Apolipoprotein Reference Laboratory we apply MS strategies to obtain detailed insight into the protein-to-peptide conversion in order to verify that quantifier peptides are not partly concealed in miscleaved protein backbone.

Methods: Apolipoprotein(a) (apo(a)) was digested in a non-optimal manner to enhance the number of miscleaved peptides that were identified by high resolution liquid chromatography tandem-MS measurements.

View Article and Find Full Text PDF