Publications by authors named "C Latkoczy"

Laser-induced breakdown detection (LIBD) is a promising method to detect trace amounts of nanoparticles (NP, <100 nm) in aqueous suspensions. Based on available systems, we developed a mobile LIBD, designed for on-site and on-line measurements. We used the energy ratio of every laser pulse before and after passing the laser beam through the aqueous sample as a new method to detect laser-induced plasma events.

View Article and Find Full Text PDF

Human bone and teeth fragments can be useful evidence when found in crime scenes and/or mass burials sites. The elemental and isotopic composition of these samples can provide information about environmental exposure events and could also be used to distinguish different individuals. The development and application of robust analytical methods for the quantification of trace elements in these biological matrices may lead to a better understanding of the potential utility of these measurements in forensic analyses.

View Article and Find Full Text PDF

Microbial mats collected at cold methane seeps in the Black Sea carry out anaerobic oxidation of methane (AOM) to carbon dioxide using sulfate as the electron acceptor. These mats, which predominantly consist of sulfate-reducing bacteria and archaea of the ANME-1 and ANME-2 type, contain large amounts of proteins very similar to methyl-coenzyme M reductase from methanogenic archaea. Mass spectrometry of mat samples revealed the presence of two nickel-containing cofactors in comparable amounts, one with the same mass as coenzyme F430 from methanogens (m/z = 905) and one with a mass that is 46 Da higher (m/z = 951).

View Article and Find Full Text PDF

The spatial distribution and concentration of impurities in metallurgical-grade silicon (MG-Si) samples (97-99% w/w Si) were investigated by use of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The spatial resolution (120 mum) and low limits of detection (mg kg(-1)) for quality assurance of such materials were studied in detail. The volume-dependent precision and accuracy of non-matrix-matched calibration for quantification of minor elements, using NIST SRM 610 (silicate standard), indicates that LA-ICP-MS is well suited to rapid process control of such materials.

View Article and Find Full Text PDF

Objective: We sought to investigate whether intrapleural topical application of cisplatin with a surgical carrier has a prolonged local tissue level in comparison with cisplatin solution while reducing systemic toxicity.

Methods: Forty immune-competent Fischer rats were inoculated with 10(6) mesothelioma cells. Ten days later, left pneumonectomy with tumor debulking was performed.

View Article and Find Full Text PDF