Purpose: To provide beam quality correction factors ( ) for detectors used in Ir brachytherapy dosimetry measurements.
Materials And Methods: Ten detectors were studied, including the PTW 30013 and Exrading12 Farmer large cavity chambers, seven medium (0.1-0.
The radiological examination frequency, i.e. the number of examinations performed annually, is necessary for estimating the collective effective dose of the population from medical exposures with ionizing radiation.
View Article and Find Full Text PDFThe escalating use of Computed Tomography (CT) imaging necessitates establishment and periodic revision of Diagnostic Reference Levels (DRLs) to ensure patient protection optimization. This paper presents the outcomes of a national survey conducted from 2019 to 2022, focusing on revising DRLs for adult CT examinations. Dosimetric data from 127 scanners in 120 medical facilities, representing 25% of the country's CT scanners, were collected, emphasizing geographic distribution and technology representation.
View Article and Find Full Text PDFBackground: The Southeast European (SEE) region of 10 countries and about 43 million people differs from Western Europe in that most SEE countries lack active cancer registries and have fewer diagnostic imaging devices and radiotherapy (RT) units. The main objective of this research is to initiate a common platform for gathering SEE regional cancer data from the ground up to help these countries develop common cancer management strategies.
Methods: To obtain detailed on-the-ground information, we developed separate questionnaires for two SEE groups: a) ONCO - oncologists regarding cancer treatment modalities and the availability of diagnostic imaging and radiotherapy equipment; and b) REG - national radiation protection and safety regulatory bodies regarding diagnostic imaging and radiotherapy equipment in SEE facilities.
Covid-19 pandemic imposes crucial social distancing rules and restriction measures; therefore, the access to facilities and sites, in order to perform on-site inspections, became difficult or not feasible. Greek Atomic Energy Commission (EEAE) adopted remote virtual inspections (RVIs) of facilities and practices applying ionising radiation and magnetic resonance imaging installations, in order to continue discharging its regulatory duty of inspection, effectively. This study presents the experience gained and lessons learnt from the implementation of the RVIs and explores the RVIs perception by the stakeholders.
View Article and Find Full Text PDF