Publications by authors named "C G Ioannides"

Background: The main goal of the study was to find the magnetic resonance imaging (MRI) parameters that optimize contrast between tissue and thermal lesions produced by focused ultrasound (FUS) using T1-weighted (T1-W) and T2-weighted (T2-W) fast spin echo (FSE) sequences.

Methods: FUS sonications were performed in porcine tissue using a single-element FUS transducer of 2.6 MHz in 1.

View Article and Find Full Text PDF

Purpose: The current study provides insights into the challenges of safely operating a magnetic resonance imaging (MRI)-guided focused ultrasound (MRgFUS) robotic system in a high-field MRI scanner in terms of robotic motion accuracy.

Materials And Methods: Grid sonications were carried out in phantoms and excised porcine tissue in a 3T MRI scanner using an existing MRgFUS robotic system. Fast low-angle shot-based magnetic resonance thermometry was employed for the intraprocedural monitoring of thermal distribution.

View Article and Find Full Text PDF

The purpose of this study was to investigate whether a dynamic warm-up either with weighted vests (WVs) or with resistance bands (RBs) may enhance the physical fitness and combat ability of kumite karate athletes. Nine male athletes (age range from 16 to 30 years), participated in this study. Athletes followed three different warm-up programs in a randomized order: (a) with their body mass only (C), (b) with a WV of 10% load of their body mass and (c) with a wearable RB of 10% tension of their body mass.

View Article and Find Full Text PDF

Purpose: The study aimed to compare the performance of eight commercially available single-element High Intensity Focused Ultrasound (HIFU) transducers in terms of Magnetic Resonance Imaging (MRI) compatibility.

Methods: Imaging of an agar-based MRI phantom was performed in a 3 T MRI scanner utilizing T2-Weighted Fast Spin Echo (FSE) and Fast low angle shot (FLASH) sequences, which are typically employed for high resolution anatomical imaging and thermometry, respectively. Reference magnitude and phase images of the phantom were compared with images acquired in the presence of each transducer in terms of the signal to noise ratio (SNR), introduced artifacts, and overall image quality.

View Article and Find Full Text PDF

Duodenal trauma resulting in perforation is rare and management can be challenging due to injuries in other organs and vascular structures. Primary repair is the preferred option and is technically feasible even in cases with large defects. In more complex injuries with pancreaticobiliary tract involvement, damage control techniques and staged procedures may be required.

View Article and Find Full Text PDF