Publications by authors named "C Fulcheri"

This large multicenter study of 37 magnetic resonance imaging scanners aimed at characterizing, for the first time, spatial profiles of inaccuracy (namely, Δ-profiles) in apparent diffusion coefficient (ADC) values with varying acquisition plan orientation and diffusion weighting gradient direction, using a statistical approach exploiting unsupervised clustering analysis. A diffusion-weighted imaging (DWI) protocol (b-value: 0-200-400-600-800-1000 s mm) with different combinations of acquisition plan orientation (axial/sagittal/coronal) and diffusion weighting gradient direction (anterior-posterior/left-right/feet-head) was acquired on a standard water phantom. For each acquisition setup, Δ-profiles along the 3 main orthogonal directions were characterized by fitting data with a second order polynomial function ().

View Article and Find Full Text PDF

As a component of myeloablative conditioning before allogeneic hematopoietic stem cell transplantation (HSCT), Total Body Irradiation (TBI) is employed in radiotherapy centers all over the world. In recent and coming years, many centers are changing their technical setup from a conventional TBI technique to multi-isocenter conformal arc therapy techniques such as Volumetric Modulated Arc Therapy (VMAT) or Helical Tomotherapy (HT). These techniques allow better homogeneity and control of the target prescription dose, and provide more freedom for individualized organ-at-risk sparing.

View Article and Find Full Text PDF

Background/aim: To compare heart, left ventricle (LV) and coronary artery dose-sparing with three-dimensional conformal radiotherapy (3D-CRT) vs. helical tomotherapy (HT) in left-sided breast cancer (BC).

Patients And Methods: 3D-CRT and HT treatments were planned for 20 patients (pts).

View Article and Find Full Text PDF

Background: Palliative radiation therapy (RT) is used to treat symptomatic rectal cancer although clinical benefits and toxicities are poorly documented. There is no consensus about the optimal RT regimen and clinical practice undergoes significant changes. Our aim was to evaluate the efficacy and toxicity of short-course (SC) RT in this setting of patients.

View Article and Find Full Text PDF

Background: In patients with expander-based reconstruction a few dosimetric analyses detected radiation therapy dose perturbation due to the internal port of an expander, potentially leading to toxicity or loss of local control. This study aimed at adding data on this field.

Materials And Methods: A dosimetric analysis was conducted in 30 chest wall treatment planning without and with correction for port artifact.

View Article and Find Full Text PDF