Objectives: Contact shielding (CS) of patients during X-ray studies has been used for decades to protect radiosensitive organs. This practice has not changed much despite increasing evidence that CS is not useful in many cases. The Gonad And Patient Shielding (GAPS) group-founded by representatives of the main European bodies involved in radiology-promoted this survey to assess the current practice of CS among European radiology departments and the attitude towards a non-shielding policy.
View Article and Find Full Text PDFObjectives: The main goal of this work is to design and characterize a user-friendly methodology to perform mailed dosimetric audits in high dose rate (HDR) brachytherapy for systems using either Iridium-192 (Ir) or Cobalt-60 (Co) sources.
Methods: A solid phantom was designed and manufactured with four catheters and a central slot to place one dosimeter. Irradiations with an Elekta MicroSelectron V2 for Ir, and with a BEBIG Multisource for Co were performed for its characterization.
Patient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control (AEC) systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology.
View Article and Find Full Text PDFPatient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control (AEC) systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology.
View Article and Find Full Text PDFPatient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology.
View Article and Find Full Text PDF