Objective: Sensorineural hearing loss is common with advancing age, but even with normal or near normal hearing in older persons, performance deficits are often seen for suprathreshold listening tasks such as understanding speech in background noise or localizing sound direction. This suggests there is also a more central source of the problem. Objectives of this study were to examine as a function of age (young adult to septuagenarian) performance on: 1) a spatial acuity task examining lateralization ability, and a spatial speech-in-noise (SSIN) recognition task, both measured in a hemi-anechoic sound field using a circular horizontal-plane loudspeaker array, and 2) a suprathreshold auditory temporal processing task and a spectro-temporal processing task, both measured under headphones.
View Article and Find Full Text PDFThe binaural interaction component (BIC) of the auditory brainstem response (ABR) is the difference obtained after subtracting the sum of right and left ear ABRs from binaurally evoked ABRs. The BIC has attracted interest as a biomarker of binaural processing abilities. Best binaural processing is presumed to require spectrally-matched inputs at the two ears, but peripheral pathology and/or impacts of hearing devices can lead to mismatched inputs.
View Article and Find Full Text PDFObjectives: The binaural interaction component (BIC) of the auditory brainstem response (ABR) is obtained by subtracting the sum of the monaural right and left ear ABRs from the binaurally evoked ABR. The result is a small but prominent negative peak (herein called "DN1"), indicating a smaller binaural than summed ABR, which occurs around the latency of wave V or its roll-off slope. The BIC has been proposed to have diagnostic value as a biomarker of binaural processing abilities; however, there have been conflicting reports regarding the reliability of BIC measures in human subjects.
View Article and Find Full Text PDFObjective: To determine the efficacy of "simultaneous" bilateral cochlear implantation (both implants placed during a single surgical procedure) by comparing bilateral and unilateral implant use in a large number of adult subjects tested at multiple sites.
Design: Prospective study of 37 adults with postlinguistic onset of bilateral, severe to profound sensorineural hearing loss. Performance with the bilateral cochlear implants, using the same speech processor type and speech processing strategy, was compared with performance using the left implant alone and the right implant alone.
Hyperacusis, as defined here, is a relatively rare condition in which the patient, with or without hearing loss, experiences severe loudness discomfort to everyday environmental sound levels. The case studies of 14 patients with severe hyperacusis are described; all wore passive attenuators (earplugs and/or earmuffs) in an attempt to alleviate their discomfort, frequently producing communication difficulties. These subjects were fitted binaurally with experimental electronic loudness suppression devices housed in in-the-ear casings.
View Article and Find Full Text PDF