Cardiac implantable electronic devices (CIEDs) generate substantial data, often stored in image or PDF formats. Remote monitoring, now an integral component of patient care, places considerable administrative burdens on clinicians and staff, in large part due to the challenge of integrating these data seamlessly into electronic health records. Since 2006, the Heart Rhythm Society, in collaboration with the CIED industry, has led an initiative to establish a unified standard nomenclature.

View Article and Find Full Text PDF

Aims: This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors.

Methods And Results: During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance.

View Article and Find Full Text PDF

Objectives: We tested a simple noninvasive method for cardiac resynchronization therapy (CRT) optimization using standard finger photoplethysmography (FPPG).

Background: CRT can increase left ventricular cardiac output in patients with heart failure and ventricular conduction delay. Optimal therapy delivery depends on an appropriate AV delay.

View Article and Find Full Text PDF

Background: Single-site ventricular pacing in patients with heart failure, atrial fibrillation, and severe atrioventricular (AV) nodal block risks the generation of discoordinate contraction. Whether altering the site of stimulation can offset this detrimental effect and what role sequential right ventricular-left ventricular (RV-LV) stimulation might play in such patients remain unknown.

Methods And Results: Nine subjects with heart failure (ejection fraction, 14% to 30%), atrial fibrillation, and AV block were studied by pressure-volume analysis.

View Article and Find Full Text PDF

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE).