Radiographic imaging using X-rays is a tool for basic research and applications in industry, materials science, and medical diagnostics. In this article, we present a novel approach for the generation of X-rays using a vacuum-free microplasma by femtosecond fiber laser. By tightly focusing a laser pulse onto a micrometer-sized solid density near-surface plasma from a rotating copper target, we demonstrate the generation of Cu K-photons (8-9 keV) with high yield ∼ 1.
View Article and Find Full Text PDFThe proximal caudal vertebrae and notochord in thick-toed geckos (TG) (, Gray, 1864) were investigated after a 30-day space flight onboard the biosatellite Bion-M1. This region has not been explored in previous studies. Our research focused on finding sites most affected by demineralization caused by microgravity (G0).
View Article and Find Full Text PDFTo solve the problems of spectral tomography, an X-ray optical scheme was proposed, using a crystal analyzer in Laue geometry between the sample and the detector, which allowed for the selection of predetermined pairs of wavelengths from the incident polychromatic radiation to obtain projection images. On a laboratory X-ray microtomography setup, an experiment was carried out for the first time where a mixture of micro-granules of sodium chloride NaCl, silver behenate AgCHO, and lithium niobate LiNbO was used as a test sample to identify their spatial arrangement. The elements were chosen based on the presence of absorption edges in two of the elements in the energy range of the polychromatic spectrum of the probing radiation.
View Article and Find Full Text PDFBackground: The formation of concrements in human pineal gland (PG) is a physiological process and, according to many researchers, is associated with the involution of PG structures. The majority of scientific publications concern progressive calcification of PG, leaving out studies on the destruction of already formed calcified concrements. Our study fills the gap in knowledge about calcified zones destruction in PG in normal aging and neuropathological conditions, which has not been addressed until now.
View Article and Find Full Text PDFThe human olfactory bulb (OB) has a laminar structure. The segregation of cell populations in the OB image poses a significant challenge because of indistinct boundaries of the layers. Standard 3D visualization tools usually have a low resolution and cannot provide the high accuracy required for morphometric analysis.
View Article and Find Full Text PDFObjectives: To study the oxide layer stability of certified dental implants of system "P", made based on TiO alloy with carbon coating. To perform a comparative statistical analysis of the obtained data with the available data for the dental implants of systems "A" and "B".
Methods: X-ray microtomography and X-ray fluorescence analysis were used to study soft tissue biopsy specimens.
The Mongolian gerbil displays unique physiological and anatomical features that make this species an attractive object for biological experiments in space. However, until recently, the Mongolian gerbil has remained a novel, mostly unstudied animal model in investigating bone loss in weightlessness (G). After 12 days of orbital Foton-M3 mission, the humerus of Mongolian gerbils has been studied here micro-computed tomography (micro-CT) to quantify bone morphometric parameters.
View Article and Find Full Text PDFDetailed and accurate three-dimensional (3D) information about the morphology of hierarchically structured materials is derived from multi-scale X-ray computed tomography (XCT) and subsequent 3D data reconstruction. High-resolution X-ray microscopy and nano-XCT are suitable techniques to nondestructively study nanomaterials, including porous or skeleton materials. However, laboratory nano-XCT studies are very time-consuming.
View Article and Find Full Text PDFIn this study, the nanoscale transformation of the polylactic-co-glycolic acid (PLGA) internal structure, before and after its supercritical carbon dioxide (sc-CO) swelling and plasticization, followed by foaming after a CO pressure drop, was studied by small-angle X-ray scattering (SAXS) for the first time. A comparative analysis of the internal structure data and porosity measurements for PLGA scaffolds, produced by sc-CO processing, on a scale ranging from 0.02 to 1000 μm, was performed by SAXS, helium pycnometry (HP), mercury intrusion porosimetry (MIP) and both "lab-source" and synchrotron X-ray microtomography (micro-CT).
View Article and Find Full Text PDFFor the High-Energy-Density (HED) beamline at the SASE2 undulator of the European XFEL, a hard X-ray split-and-delay unit (SDU) has been built enabling time-resolved pump/probe experiments with photon energies between 5 keV and 24 keV. The optical layout of the SDU is based on geometrical wavefront splitting and multilayer Bragg mirrors. Maximum delays between Δτ = ±1 ps at 24 keV and Δτ = ±23 ps at 5 keV will be possible.
View Article and Find Full Text PDFThis article demonstrates how a combination of well-known tools-a standard 2D detector (CCD (charge-coupled device) camera) and a crystal analyzer-can improve the multimodality of X-ray imaging and tomographic sensing. The use of a crystal analyzer allowed two characteristic lines of the molybdenum anode-Kα and Kβ-to be separated from the polychromatic radiation of the conventional X-ray tube. Thus, as a result of one measurement, three radiographic projections (images) were simultaneously recorded.
View Article and Find Full Text PDFPineal gland (PG) is a part of the human brain epithalamus that plays an important role in sleep, circadian rhythm, immunity, and reproduction. The calcium deposits and lesions in PG interfere with normal function of the organ and can be associated with different health disorders including serious neurological diseases. At the moment, the detailed mechanisms of PG calcifications and PG lesions formation as well as their involvement in pathological processes are not fully understood.
View Article and Find Full Text PDFIn the present work, a method for adjusting a crystal analyzer to separate two characteristic lines from the spectrum of a conventional X-ray tube for simultaneous registration of tomographic projections is proposed. The experimental implementation of this method using radiation of a molybdenum anode (α, β lines) and a silicon Si(111) crystal analyzer in Laue geometry is presented. Projection images at different wavelengths are separated in space and can be recorded independently for further processing.
View Article and Find Full Text PDFBackground And Objective: The laser-induced stress relaxation provides new prospects to obtain stable long fragments of costal cartilage for autoimplantation avoiding the risk of spontaneous deformation and poor engraftment. However, the age-related alterations of cartilage may sufficiently influence its interaction with infrared (IR) laser radiation and disrupt the effectiveness and safety of the technique. The aim of the work is to study the influence of the structural quality of costal cartilage on its interaction with IR laser and efficiency of obtaining of curved implants for trachea surgery.
View Article and Find Full Text PDFThe unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ∼10 within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal.
View Article and Find Full Text PDFReptiles are a rare model object for space research. However, some reptile species demonstrate effective adaptation to spaceflight conditions. The main scope of this review is a comparative analysis of reptile experimental exposure in weightlessness, demonstrating the advantages and shortcomings of this model.
View Article and Find Full Text PDFHigh resolution X-ray imaging is crucial for many high energy density physics (HEDP) experiments. Recently developed techniques to improve resolution have, however, come at the cost of a decreased field of view. In this paper, an innovative experimental detector for X-ray imaging in the context of HEDP experiments with high spatial resolution, as well as a large field of view, is presented.
View Article and Find Full Text PDFThis study theoretically analyzes an increase in X-ray absorption by a grazing incidence mirror due to its surface roughness. We demonstrate that the increase in absorption can be several hundred times larger than predicted by the Nevot-Croce formula. As a result, absorption enhances by several times compared to a perfectly smooth mirror despite the extremely small grazing angle of an incident X-ray beam (a fraction of the critical angle of the total external reflection) and the high quality of the reflecting surface (the roughness height was 0.
View Article and Find Full Text PDFThis article describes the () package, a new interactive software framework for coherent and partially coherent X-ray wavefront propagation simulations. The package has been developed at European XFEL for users at the existing and emerging free-electron laser (FEL) facilities, as well as at the third-generation synchrotron sources and future diffraction-limited storage rings. The addresses the needs of beamline scientists and user groups to facilitate the design, optimization and improvement of X-ray optics to meet their experimental requirements.
View Article and Find Full Text PDFThe advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. We demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2016
A new phenomenon on X-ray optics surfaces has been observed: the growth of nano-dots (40-55 nm diameter, 8-13 nm height, 9.4 dots µm(-2) surface density) on the grazing-incidence mirror surface under irradiation by the free-electron laser (FEL) FLASH (5-45 nm wavelength, 3° grazing-incidence angle). With a model calculation it is shown that these nano-dots may occur during the growth of a contamination layer due to polymerization of incoming hydrocarbon molecules.
View Article and Find Full Text PDFThe paper presents a clinical case of jejunal duplication, a rare anomaly of the gastrointestinal tract. It describes an algorithm for hospital diagnostic and therapeutic measures. The capacities of radiodiagnostic studies, such as ultrasonography and magnetic resonance imaging, applied to this clinical case, are analyzed.
View Article and Find Full Text PDFA combination of X-ray tomography at different wavelengths and X-ray fluorescence analysis was applied in the study of two types of bone tissue changes: prolonged presence in microgravity conditions and age-related bone growth. The proximal tail vertebrae of geckos were selected for investigation because they do not bear the supporting load in locomotion, which allows them to be considered as an independent indicator of gravitational influence. For the vertebrae of geckos no significant differences were revealed in the elemental composition of the flight samples and the synchronous control samples.
View Article and Find Full Text PDF