Publications by authors named "Buttarello M"

Introduction: Hereditary spherocytosis (HS) is a congenital haemolytic disorder, resulting from plasma membrane protein deficiency of red blood cells (RBCs). Typical pathological signs are anemia, jaundice, and splenomegaly; in newborns, jaundice is the main symptom.

Material And Methods: This study focused on the state of art about the HS diagnosis, from traditional to innovative methods, including diagnostic algorithms that can be applied for pediatric and adult patients, for different laboratory diagnostic levels.

View Article and Find Full Text PDF

So-called "reticulated" or "immature platelets," which are newly released into the circulation, are more reactive than mature platelets, contain more RNA, and can be counted using flow cytometry after staining with thiazole orange or using some fully automated hematology analyzers, albeit with numerical disagreement. This review provides an overview of the state of the art of available technology for measuring immature or reticulated platelets (RP) with preanalytical (time stability, biological variation), analytical (methods, imprecision), and postanalytical (reference range) limitations. We also analyzed the clinical conditions in which immature/RP can be considered a diagnostic or prognostic tool (ie, differential diagnosis of thrombocytopenia, recovery after bone marrow or stem cell transplantation, risk assessment in cardiovascular diseases, response to antiplatelet drugs).

View Article and Find Full Text PDF

Background: The study endpoint was to analyze the effect of preanalytical (time, temperature, anticoagulant) and analytical (imprecision, correlation between volume and platelet concentration) variables on mean platelet volume (MPV). A further aim was to calculate in an adult population the reference intervals using the Sysmex XE-5000 analyzer. A critical evaluation was also made of the clinical utility of these parameters.

View Article and Find Full Text PDF

Introduction: In this study, analytic performance (imprecision, carryover, time stability) and diagnostic efficiency of Mindray BC-6800 analyzer to quantify reticulocytes and extended reticulocyte parameters was evaluated. Moreover, reference intervals on adult population were determined. Results were compared with those obtained by Sysmex XE-5000 analyzer.

View Article and Find Full Text PDF

Background: Iron deficiency represents the most frequent cause of anemia. To diagnose iron deficiency some biochemical tests such as serum ferritin and the transferring saturation percent (TSAT%) are usually used. Recently, some hematological parameters such as mean reticulocyte hemoglobin content (CHr or Ret-He) and percentage of hypochromic RBCs (Hypo% or %Hypo-He) were proposed as alternative to biochemical tests.

View Article and Find Full Text PDF

Introduction: Anemia is a global problem affecting the population in both developing and developed countries, and there is a debate on which hemoglobin level limit should be used to define anemia in general population and particularly in the elderly. We present herein a laboratory approach to diagnosing the possible causes of anemia based on traditional and new erythroid parameters. In this article, we provide practical diagnostic algorithms that address to differential diagnosis of anemia.

View Article and Find Full Text PDF

Since red blood cells (RBCs) lack nuclei and organelles, cell membrane is their main load-bearing component and, according to a dynamic interaction with the cytoskeleton compartment, plays a pivotal role in their functioning. Even if erythrocyte membranes are available in large quantities, the low abundance and the hydrophobic nature of cell membrane proteins complicate their purification and detection by conventional 2D gel-based proteomic approaches. So, in order to increase the efficiency of RBC membrane proteome identification, here we took advantage of a simple and reproducible membrane sub-fractionation method coupled to Multidimensional Protein Identification Technology (MudPIT).

View Article and Find Full Text PDF
Article Synopsis
  • The study explored alternative diagnostic methods for iron deficiency in hemodialysis patients, focusing on reticulocyte hemoglobin content (CHret) and hypochromic RBC percentage (HYPO%), compared to traditional biochemical tests.
  • Reticulocyte indices and erythrocyte parameters showed better predictive abilities for iron deficiency, with area under the curve (AUC) values indicating their effectiveness.
  • Results suggest that newly proposed measures, Ret-He and %Hypo-He, are clinically useful and provide information comparable to traditional methods in assessing iron responsiveness.
View Article and Find Full Text PDF

The CBC count and leukocyte differential count (LDC) are among the most frequently requested clinical laboratory tests. These analyses are highly automated, and the correct interpretation of results requires extensive knowledge of the analytic performance of the instruments and the clinical significance of the results they provide. In this review, we analyze the state of the art regarding traditional and new parameters with emphasis on clinical applications and analytic quality.

View Article and Find Full Text PDF
Article Synopsis
  • Quality improvements in clinical laboratories are often limited because most errors occur in the preanalytical phase, particularly during specimen collection and handling.
  • Many preanalytical errors stem from system flaws and lack of proper auditing of staff, resulting in unsuitable specimens that are misidentified or contaminated.
  • The Italian Inter-society group has issued recommendations to help detect and manage these unsuitable samples, focusing on reducing variability in lab testing.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how effectively visceral proteins (albumin, prealbumin, RBP, and transferrin) indicate protein energy malnutrition in elderly patients, particularly their correlation with body composition.
  • The research involved 113 elderly subjects, comparing underweight individuals with normal/overweight ones while excluding those with acute illnesses or inflammatory conditions.
  • Results showed that lower levels of albumin, prealbumin, and RBP were linked to underweight subjects, highlighting their potential in assessing malnutrition, while transferrin did not correlate with nutritional status as effectively.
View Article and Find Full Text PDF

Background: Quality specifications for automated blood cell counts include topics that go beyond the traditional analytic stage (imprecision, inaccuracy, quality control) and extend to pre- and post-analytic phases.

Methods: In this review pre-analytic aspects concerning the choice of anticoagulants, maximum conservation times and differences between storage at room temperature or at 4 degrees C are considered. For the analytic phase, goals for imprecision and bias obtained with various approaches (ratio to biologic variation, state of the art, specific clinical situations) are evaluated.

View Article and Find Full Text PDF

To verify their clinical usefulness in diagnosis and early response to therapy of sideropenic anemia, we compared the behavior of the reticulocyte parameter (RET-Y), a raw measure dependent on size and content of the cell, generated by the Sysmex XE 2100, with the mean reticulocyte volume (MCVr) and mean reticulocyte hemoglobin content (CHr) from the Bayer ADVIA 120 in healthy subjects and patients with iron deficiency anemia. Correlations were high (r = 0.88 and r = 0.

View Article and Find Full Text PDF
Article Synopsis
  • HTLV-1 infections are rare in Italy and Europe, mostly affecting individuals from endemic areas, with HTLV-1-associated leukemia/lymphoma (ATLL) being especially aggressive and hard to identify outside these regions.
  • A case is presented involving an elderly Italian woman with no known risk factors who developed a rapidly fatal ATLL characterized by an abdominal lymphomatous mass and circulating leukemic cells.
  • Genetic analyses showed multiple T-cell clones in both the tumor and blood, indicating tumor spread post-surgery, and phylogenetic studies revealed her HTLV-1 isolate as belonging to the cosmopolitan subtype A.
View Article and Find Full Text PDF

The spun packed cell volume (PCV, hematocrit) is a key measurement on which are based hematology instrument calibration, reference range determination, and assignment of values to calibrators/controls. In 2001, the International Council for Standardization in Haematology (ICSH) recommended a Reference PCV method, which is fully traceable to the ICSH reference hemoglobin method. Because of its complexity, however, this method is impractical for occasional use in routine laboratories and is therefore intended primarily for use by manufacturers of capillary microhematocrit tubes, liquid calibrators, and multichannel analyzers.

View Article and Find Full Text PDF

We performed a parallel evaluation of 5 automated reticulocyte counters to produce the immature reticulocyte fraction (IRF). We analyzed 225 samples from healthy control subjects, 115 from patients with various diseases, 38 with advanced aplasia, and 22 in early erythropoietic recovery after chemotherapy or bone marrow transplantation. The reference intervals were different for each instrument (ADVIA 120, 0.

View Article and Find Full Text PDF
Article Synopsis
  • The study assessed how malnutrition indicators relate to functional status changes in older adults in nursing homes.
  • The research involved 98 subjects over two years, measuring various nutritional and body composition parameters.
  • Results showed that lower albumin levels and reduced body cell mass were linked to increased disability, indicating that malnutrition could predict a decline in daily living activities.
View Article and Find Full Text PDF

We performed a parallel evaluation of 5 automated reticulocyte analyzers. The guidelines were those proposed by the National Committee for Clinical Laboratory Standards and the International Council for Standardisation in Haematology. Duplicate analyses were performed for 225 healthy subjects and 115 patients affected by various diseases.

View Article and Find Full Text PDF

We analysed longitudinally the numbers of CD3-CD16+ (natural killer cells, NK) and CD3-CD57+ cells (a subset of NK) in 15 IFNbeta1b- and 12 IFNbeta1a-treated relapsing-remitting multiple sclerosis (RRMS) patients. IFNbeta1b (Betaferon)-treated RRMS patients showed a rapid and marked reduction in the number of both NK subsets which started 1 month after therapy initiation, and reached highest significance after 3 months (P=0.000); however, figures reverted to pre-treatment values following the appearance of anti-IFNbeta antibodies.

View Article and Find Full Text PDF

To identify immunological markers that could be used to monitor relapsing-remitting multiple sclerosis (RRMS) course/activity during interferon beta 1b (IFN beta 1b) therapy, we longitudinally studied HLA-DR and CD25 expression by T lymphocytes in 15 IFN beta 1b-treated RRMS patients. Peripheral blood T cell subsets were analysed before therapy (T0), and after 1 (T1), 2 (T2), 3 (T3), 6 (T4) and 12 (T5) months after therapy initiation. HLA-DR expression and the CD3+HLA-DR+ T cell number showed a peculiar trend in almost all (14/15) the patients: a significant decrease at T1 and T2 followed by a return to pre-treatment levels from T3 to T5.

View Article and Find Full Text PDF

The time-course of CD25 (the 55-kD/alpha subunit of the interleukin-2 (IL-2) receptor) expression on CD4+ T lymphocytes, and serum levels of soluble IL-2 receptors (sIL-2R) and IL-2 were evaluated in relapsing-remitting multiple sclerosis (RRMS) patients treated with interferon beta-1b (IFNbeta1b). Peripheral blood samples were collected before therapy (T0), and 1 (T1), 2 (T2), 3 (T3), 6 (T4), and 12 (T5) months after therapy initiation. While at T1 and T2, half the patients showed an increased number of circulating CD4+ CD25+ lymphocytes and an up-regulation of CD25 expression, at T3 this T-cell subset was significantly reduced in all the patients.

View Article and Find Full Text PDF
Article Synopsis
  • - The study assessed the performance of the Sysmex SE-9000 hematology analyzer for differential leukocyte counts, using a sample of 462 subjects and comparing its results with other methods like Bayer H6000, Coulter MAXM, and manual microscopy according to clinical guidelines.
  • - The SE-9000 showed low imprecision for most leukocyte subpopulations except for basophils, correlating well with other methods, although its measurement of neutrophils and lymphocytes had some discrepancies when compared to microscopic counts.
  • - The analyzer demonstrated good clinical sensitivity, particularly in detecting immature granulocytic cells, with an impressive agreement rate for distributional abnormalities (89.6%).
View Article and Find Full Text PDF

In this study the ability of the Coulter MAXM analyzer to quantify reticulocytes was evaluated. The results were compared with those obtained by a microscopic method according to NCCLS H44-P recommendations and with the results from the automated analyzer Sysmex R-1000. Duplicate samples from 330 patients were analyzed.

View Article and Find Full Text PDF

Objective: To evaluate the performance of the new commercial Miles H.3 RTX analyzer in counting reticulocytes.

Methods And Patients: The results from the counter were compared to those obtained from microscopic methods, following the National Committee for Clinical Laboratory Standards H44-P guidelines, and to the results from the Sysmex R-1000 counter.

View Article and Find Full Text PDF