Eur J Nucl Med Mol Imaging
March 2010
Unlabelled: Rheumatoid arthritis (RA) involves the accumulation of monocyte-derived macrophages in the affected synovial tissue. This process of cell migration could be portrayed scintigraphically to monitor noninvasively the effects of therapy on the progress of the disease. For this purpose, labeling of purified autologous monocytes with 99mTc-hexamethylpropyleneamine oxime (99mTc-HMPAO) at very high specific radioactivity has recently been developed.
View Article and Find Full Text PDFBackground: The combined application of potent beta-emitting isotopes for therapy with remitting isotopes for scintigraphy requires a profound regimen concerning team member safety and radionuclide quantification.
Methods: We have developed materials and methods for a proper and easy manipulation of 90Y during preparation and administration of 90Y/111In pharmaceuticals used for radioimmunotherapy.
Results: The efficacy of the shielding measures is documented.
Purpose: A dynamic cardiac phantom was used as a reference to compare volumes measured with gated SPECT and 4D echocardiography.
Material And Methods: Gated SPECT data were acquired with a standard single-head gamma camera, and the volume reconstructions were carried out using the Mirage software by Segami. 4D echocardiography used a new prototype of rotating scan head to acquire ultrasound images during a cardiac cycle, used to reconstruct the volume deformations as a function of time.
Eur J Nucl Med Mol Imaging
July 2005
The European procedural guidelines for radionuclide imaging of myocardial perfusion and viability are presented in 13 sections covering patient information, radiopharmaceuticals, injected activities and dosimetry, stress tests, imaging protocols and acquisition, quality control and reconstruction methods, gated studies and attenuation-scatter compensation, data analysis, reports and image display, and positron emission tomography. If the specific recommendations given could not be based on evidence from original, scientific studies, we tried to express this state-of-art. The guidelines are designed to assist in the practice of performing, interpreting and reporting myocardial perfusion SPET.
View Article and Find Full Text PDFPurpose: (123)I presents imaging problems owing to high-energy photon emission. We investigated the influence of collimators on (123)I-MIBG heart/mediastinum ratios (H/M ratios). Secondly, we assessed the influence on H/M ratios of different activity concentrations, simulating clinical conditions.
View Article and Find Full Text PDFA dynamic cardiac phantom was used as a reference to compare the volumes reconstructed with 4-D echocardiography and gated single-photon emission computed tomography (SPECT). 4-D echocardiography used a new prototype of rotating scan head to acquire ultrasound (US) images during a cardiac cycle, associated with a new protocol (left ventricular 4-D or LV 4-D) to reconstruct the volume deformations of the heart as a function of time. Gated SPECT data were acquired with a standard single-head gamma camera, and the reconstructions were carried out using the Mirage software released by Segami.
View Article and Find Full Text PDFUnlabelled: Ex vivo measurements in animals are used frequently in the field of nuclear medicine for the characterization of newly developed radioligands and for drug development. In vivo SPECT would replace these ex vivo measurements in a relatively large number of cases if one were able to adequately image small organs. The pinhole collimator has been used extensively to obtain greater detail in planar imaging.
View Article and Find Full Text PDFThe main aim of the EANM Task Group on Quality Assurance and Standardisation is to develop harmonised clinical procedures that are accepted within Europe. In order to achieve an evidence-based analysis of guidelines in the 27 EANM member societies, a survey was conducted. A questionnaire in mid 1999 investigated three major questions: (1) current status of national guidelines in EANM member societies, (2) specification of the cover and level of these national guidelines, and (3) future desires for national, EANM and SNM guidelines.
View Article and Find Full Text PDFThis study reports on the distribution and radiation dosimetry of iodine-123-labelled cis-11beta-methoxy-17alpha-iodovinyloestradiol (Z-[123I]MIVE), a promising radioligand for imaging of oestrogen receptors (ERs) in human breast cancer. Whole-body scans were performed up to 24 h after intravenous injection of 138-193 MBq Z-[123I]MIVE in five healthy female volunteers, four with and one without thyroid blockade. Blood samples were taken at various times up to 24 h after injection.
View Article and Find Full Text PDFThis study reports on the biodistribution and radiation dosimetry of iodine-123-labelled N-omega-(flu- oropropyl)-2beta-carbomethoxy-3beta-(4-iodophenyl)tropane ([123I]FP-CIT), a promising radioligand for the imaging of dopamine transporters. In 12 healthy volunteers, conjugate whole-body scans were performed up to 48 h following intravenous injection of approximately 100 MBq [123I]FP-CIT. Attenuation correction was performed using a transmission whole-body scan obtained prior to injection of the radioligand, employing a 123I flood source.
View Article and Find Full Text PDFA survey of all member societies of the European Association of Nuclear Medicine has shown that a satisfactory degree of harmonisation exists for the quality assurance of the preparation and handling of radiopharmaceuticals and the performance of nuclear medicine instrumentation. However, variations were found in acquisition protocols, data analysis and the interpretation and presentation of clinical results. Harmonisation of these areas of a nuclear medicine investigation would help ensure the overall quality.
View Article and Find Full Text PDFFactors contributing to the quantification of the central benzodiazepine receptor binding potential in vivo using 123I-iomazenil and single photon emission computed tomography (SPECT) were analysed in phantom studies and in volunteers. SPECT was performed with the SME810 multidetector system. The Hoffman three-dimensional brain phantom was used to investigate linearity and reproducibility of SPECT results using different 123I activity concentrations.
View Article and Find Full Text PDFThe distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.
View Article and Find Full Text PDFLiver regeneration and restoration of liver function were studied in six patients who underwent partial hepatectomy with removal of 30-70% of the liver. Liver volume and liver regeneration were studied by single-photon computed tomography (SPECT), using 99mTc-colloid as tracer. The method was assessed in 11 patients by comparing the pre- and post-operative volume measurements with the volume of the resected liver mass.
View Article and Find Full Text PDFTen gated cardiac software phantoms, representing normal and abnormal clinical conditions, were transferred to 9 different computer systems and tested with 11 cardiac programmes. Problems of inappropriate data format were encountered when analysing the phantoms on other systems. The global left ventricular ejection fraction (LVEF) values resulting from the different programmes were compared.
View Article and Find Full Text PDFIn order to meet an increasing demand for a standard file format which would facilitate the exchange of image files from one computer to another, the protocol initiated by Report #10 of the American Association of Physicists in Medicine has been adopted. This protocol uses the concept of an ASCII file in which key-value pairs are used to describe the various parameters of the image file. Keys specific to nuclear medicine image files have been established and are published here.
View Article and Find Full Text PDFSixteen European countries participated in this WHO-IAEA intercomparison for which transmission CAP (College of American Pathologists) thyroid and IAEA-WHO liver phantoms were used. A total of 257 laboratories submitted 428 image evaluation reports. Overall results showed differences in performance between the various countries but similarities in performance for two gamma camera subgroups defined by year of manufacture, before and after 1980.
View Article and Find Full Text PDFCollimator hole angulation was measured at 16 locations in three collimators used in SPECT. The parallel hole collimator measured -0.1 +/- -0.
View Article and Find Full Text PDFNucl Med Commun
January 1986
Ejection fraction results obtained from the Vanderbilt rotating cardiac phantom exhibit a strong dependence on the algorithms used to derive the time--activity curves and calculate the ejection fraction from those curves. This problem is caused because the background chamber is located behind the rotating attenuator which is used to produce the pseudo ejection fraction. As a result, the counts due to background in both the regions on the 'left ventricle' and the area assigned for background correction do not remain constant during the 'cardiac cycle'.
View Article and Find Full Text PDFA rotating cardiac phantom with three possible ejection fraction (EF) values was used in conjunction with a scintillation camera employing energy correction and count skim arithmetic for uniformity correction. Studies were collected with and without any correction, with the energy window of the analyzer set properly, and with the camera properly tuned. The uniformity was then degraded in one experiment by off-setting the analyzer window both high and low with respect to the primary photopeak and in another experiment by de-tuning a selected photomultiplier tube.
View Article and Find Full Text PDF