Publications by authors named "Burriesci G"

Chitosan is gaining scientific recognition as a hydrogel in bone tissue engineering (BTE) due to its ability to support osteoblast attachment and proliferation. However, its low mechanical strength and lack of structural integrity limit its application. Nanometric hydroxyapatite (HA) is used as a filler to enhance the mechanical properties and osteoinductivity of hydrogels.

View Article and Find Full Text PDF

Cardiovascular diseases (CVDs) were responsible for approximately 19 million deaths in 2020, marking an increase of 18.7% since 2010. Biological decellularized patches are common therapeutic solutions for CVD such as cardiac and valve defects.

View Article and Find Full Text PDF

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Introduction: Statistical shape analysis (SSA) with clustering is often used to objectively define and categorise anatomical shape variations. However, studies until now have often focused on simplified anatomical reconstructions, despite the complexity of studied anatomies. This work aims to provide insights on the anatomical detail preservation required for SSA of highly diverse and complex anatomies, with particular focus on the left atrial appendage (LAA).

View Article and Find Full Text PDF

Inversion of the left atrial appendage is a rare phenomenon, which may occur during the de-airing maneuvers associated to routinely performed surgery procedures, such as cardiopulmonary bypass or left ventricular assist device implantation. In this case, the body of the inverted appendage can obstruct the mitral valve leading to severe complications. The mechanisms are still poorly known, and more specific studies are needed to better understand its causes and identify mitigating strategies.

View Article and Find Full Text PDF

Background: Complications of atrial fibrillation (AF) include ischemic events originating within the left atrial appendage (LAA), a protrusion of the left atrium with variable morphological characteristics. The role of the patient specific morphology and pathological haemodynamics on the risk of ischemia remains unclear.

Methods: This work performs a comparative assessment of the hemodynamic parameters among patient-specific LAA morphologies through fluid-structure interaction computational analyses.

View Article and Find Full Text PDF

Background And Objective: Fluid-structure interaction (FSI) is required in the study of several cardiovascular engineering problems were the mutual interaction between the pulsatile blood flow and the tissue structures is essential to establish the biomechanics of the system. Traditional FSI methods are partitioned approaches where two independent solvers, one for the fluid and one for the structure, are asynchronously coupled. This process results into high computational costs.

View Article and Find Full Text PDF

Biological soft tissues and polymers used in biomedical applications (e.g. in the cardiovascular area) are hyperelastic incompressible materials that commonly operate under multi-axial large deformation fields.

View Article and Find Full Text PDF

Heart valve disease is a major cause of mortality and morbidity worldwide with no effective medical therapy and no ideal valve substitute emulating the extremely sophisticated functions of a living heart valve. These functions influence survival and quality of life. This has stimulated extensive attempts at tissue engineering "living" heart valves.

View Article and Find Full Text PDF

Objective: Aortic stenos (AS) is a heart valve disease that commonly affects the elderly. Transcatheter aortic valve implantation is a minimally invasive treatment that allows to replace the function of the diseased native valve with a prosthetic device, relying on catheters for device implantation. According to the current clinical guidelines, the choice of the implanted device is based on preoperative sizing determined by image-based technology.

View Article and Find Full Text PDF

In this paper a novel model, based on the smoothed particle hydrodynamics (SPH) method, is proposed to simulate thrombus formation. This describes the main phases of the coagulative cascade through the balance of four biochemical species and three type of platelets. SPH particles can switch from fluid to solid phase when specific biochemical and physical conditions are satisfied.

View Article and Find Full Text PDF

Objectives: Valve-sparing procedures are surgical techniques allowing to restore adequate function of the native aortic valve by replacing the dysfunctional ascending aorta with a prosthetic conduit. A number of techniques are currently used, such as Yacoub's remodelling and David's reimplantation, based on a regular straight conduit. More recently, the De Paulis proposed the use of bulging conduits to reconstruct the shape of the Valsalva sinuses.

View Article and Find Full Text PDF

Aortic valvuloplasty is a minimally invasive procedure for the dilatation of stenotic aortic valves. Rapid ventricular pacing is an established technique for balloon stabilization during this procedure. However, low cardiac output due to the pacing is one of the inherent risks, which is also associated with several potential complications.

View Article and Find Full Text PDF

Background: A large majority of thrombi causing ischemic complications under atrial fibrillation (AF) originate in the left atrial appendage (LAA), an anatomical structure departing from the left atrium, characterized by a large morphological variability between individuals. This work analyses the hemodynamics simulated for different patient-specific models of LAA by means of computational fluid-structure interaction studies, modeling the effect of the changes in contractility and shape resulting from AF.

Methods: Three operating conditions were analyzed: sinus rhythm, acute atrial fibrillation, and chronic atrial fibrillation.

View Article and Find Full Text PDF

Nickel-Titanium (NiTi) shape memory alloys subjected to cyclic loading exhibit reversible temperature changes whose modulation is correlated with the applied load. This reveals the presence of reversible thermomechanical heat sources activated by the applied stresses. One such source is the elastocaloric effect, accounting for the latent heat of Austenite-Martensite phase transformation.

View Article and Find Full Text PDF

Objective: There is growing interest in the application of genetically engineered reduced antigenicity animal tissue for manufacture of bioprosthetic heart valves (BHVs) to reduce antibody induced tissue calcification and accelerated structural valve degeneration (SVD). This study tested biological equivalence of valves made from Gal-knockout (GalKO) and standard porcine pericardium after 90-day mitral valve implantation in sheep.

Methods: GalKO (n = 5) and standard (n = 5) porcine pericardial BHVs were implanted in a randomized and blind fashion into sheep for 90-days.

View Article and Find Full Text PDF

Flow-sensitive four-dimensional Cardiovascular Magnetic Resonance Imaging (4D Flow CMR) has increasingly been utilised to characterise patients' blood flow, in association with patiens' state of health and disease, even though spatial and temporal resolutions still constitute a limit. Computational fluid dynamics (CFD) is a powerful tool that could expand these information and, if integrated with experimentally-obtained velocity fields, would enable to derive a large variety of the flow descriptors of interest. However, the accuracy of the flow parameters is highly influenced by the quality of the input data such as the anatomical model and boundary conditions typically derived from medical images including 4D Flow CMR.

View Article and Find Full Text PDF

This work is the result of a campaign of measures of exposure levels to magnetic field gradients (GMF) generated by magnetic resonance imaging (MRI) tomographs, to which both healthcare staff and any persons accompanying patients who remain inside the magnet room are exposed while performing a diagnostic Investigation. The study was conducted on three MRI tomographs with a static magnetic induction field up to 1.5 T installed in two hospitals of Lombardy.

View Article and Find Full Text PDF

Atrial fibrillation () is a common arrhythmia mainly affecting the elderly population, which can lead to serious complications such as stroke, ischaemic attack and vascular dementia. These problems are caused by thrombi which mostly originate in the left atrial appendage (), a small muscular sac protruding from left atrium. The abnormal heart rhythm associated with results in alterations in the heart muscle contractions and in some reshaping of the cardiac chambers.

View Article and Find Full Text PDF

Objective: This study investigates the effect of transcatheter aortic valve (TAV) angular alignment on the postprocedure haemodynamics. TAV implantation has emerged as an effective alternative to surgery when treating valve dysfunction. However, the benefit of avoiding surgery is paid back by the inability to remove the native diseased leaflets and accurately position the device in relation to the aortic root, and the literature has shown the root anatomy and substitute position can play an essential role on valve function.

View Article and Find Full Text PDF

Transapical off-pump mitral valve repair with neochord implantation is an established technique for minimally-invasive intervention on mitral valve prolapse/flail. The procedure involves the positioning of artificial chords, whose length/tension is adjusted intraoperatively, adopting different methods based on the experience of the surgeon. This unsystematic approach occasionally leads to complications such as leaflet rupture and excessive/insufficient load on the neochords.

View Article and Find Full Text PDF

This study aims at achieving a proof-of-concept for a novel device designed to occlude the orifices that may form between transcatheter valves and host tissues after TAVI. The device effect on the performance of a SAPIEN XT with a paravalvular gap was assessed into an in vitro and ex vivo pulse duplicator. The in vitro tests were performed complying with the standard international regulations, measuring the trasvalvular pressure and regurgitant volumes with and without the paravalvular gap, and with the occluder correctly positioned into the gap.

View Article and Find Full Text PDF

Objectives: We examined the incidence, the impact of subsequent cerebrovascular events and the clinical or procedural predictors of leaflet thrombosis (LT) in patients undergoing transcatheter aortic valve implantation (TAVI).

Methods: MEDLINE/PubMed was systematically screened for studies reporting on LT in TAVI patients. Incidence [both clinical and subclinical, i.

View Article and Find Full Text PDF

Background And Objective: Clinical evaluation of pacing therapy in mitigating the aortic insufficiency after transchateter aortic valve implantation often gives contradictory outcomes. This study presents an in vitro investigation aimed at clarifying the effect of pacing on paravalvular leakage.

Methods: A series of in vitro tests reproducing the heart operating changes clinically obtained by pacing was carried out in a 26 mm Edwards Sapien XT prosthesis with mild paravalvular leakage.

View Article and Find Full Text PDF

Bioprosthetic leaflets made from animal tissues are used in the majority of surgical and transcatheter cardiac valve replacements. This study develops a new surgical bioprosthesis, using porcine pericardial leaflets. Porcine pericardium was obtained from genetically engineered pigs with a mutation in the GGTA-1 gene (GTKO) and fixed in 0.

View Article and Find Full Text PDF