Interdiscip Cardiovasc Thorac Surg
September 2024
(1) Background: This study aimed to analyse the hydrodynamic performance of two generations of self-expanding transcatheter heart valves (THV) as a valve-in-valve (ViV) in different surgical aortic valve (SAV) models under standardised conditions. The nitinol-based Evolut R valve is frequently used in ViV procedures. It is unclear whether its successor, the Evolut PRO, is superior in ViV procedures, particularly considering the previously implanted SAV model.
View Article and Find Full Text PDFBackground And Aims: The durability of surgical aortic valve bioprostheses (SAV) is limited by the calcification of the leaflets, which results in degeneration. In clinical routine, there seems to be substantial variability in the degeneration of specific SAV models. Our study aims to establish an in vitro calcification model for prosthetic valves, characterizing the calcification behavior of different SAVs.
View Article and Find Full Text PDFObjectives: Very precise positioning of the transcatheter heart valve (THV) inside the degenerated SAV is a crucial factor for valve-in-valve (ViV) procedure to achieve optimal hemodynamic results. Therefore, our study aimed to investigate the impact of implantation depth on functional results after ViV procedures in a standardized in vitro setting.
Methods: THV (SAPIEN 3 Ultra 23-mm size) and three SAV models (Magna Ease, Trifecta, and Hancock II-all 21-mm size) were tested at different circulatory conditions in five different positions of the THV (2-6 mm) inside the SAV.
Objectives: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material.
Methods: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit).
Introduction: Drug therapy to reduce the regurgitation fraction (RF) of high-grade aortic regurgitation (AR) by increasing heart rate (HR) is generally recommended. However, chronic HR reduction in HFREF patients can significantly improve aortic compliance and thereby potentially decrease RF. To clarify these contrasts, we examined the influence of HR, aortic compliance and stroke volume (SV) on RF in an ex vivo porcine model of severe AR.
View Article and Find Full Text PDFObjectives: We aimed to develop and validate an effective prediction model for 1-year mortality risk in elective transfemoral transcatheter aortic valve replacement (TAVR), ie, the TAVR-Risk (TARI) model.
Background: TAVR is the primary treatment for patients with symptomatic severe aortic valve stenosis; however, risk assessment tools for longer-term outcomes after TAVR remain scarce.
Methods: This retrospective cohort study used logistic regression to test univariate and multivariate associations.
Objectives: The aim of this study was to investigate the degree of functional improvement of a transcatheter heart valve (THV) for valve-in-valve after bioprosthetic valve fracture (BVF) of three small surgical aortic valve bioprostheses (SAVBP) using high-pressure balloon aortic valvuloplasty (HP-BAV) under standardized ex-vivo-conditions.
Methods: A THV 26 mm (Evolut R) and SAVBP 21 mm (Perimount Magna Ease, Trifecta, and Epic supra [n = 4] were used. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOA), minimal internal diameter (MID), and pinwheeling index (PWI) were analyzed before and after HP-BAV of the SAVBP using a noncompliant balloon.
Eur J Cardiothorac Surg
September 2022
Objectives: Selection of a surgical aortic valve (SAV) bioprosthesis model for the treatment of aortic valve disease remains controversial. The aim of this study was to characterize the functional performance of 8 SAV models in a standardized in vitro setting.
Methods: The hydrodynamic performance of 8 SAVs with labelled size 21 mm (Avalus™, Hancock® II, Mosaic® Ultra™, Perimount®, Perimount® Magna Ease, Epic™ Supra, Trifecta™ GT; Freestyle®), was investigated in a pulse duplicator.
Interact Cardiovasc Thorac Surg
August 2022
Objectives: We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study.
Methods: Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St.
Aims: The present study aims to characterize the genetic risk architecture of bicuspid aortic valve (BAV) disease, the most common congenital heart defect.
Methods And Results: We carried out a genome-wide association study (GWAS) including 2236 BAV patients and 11 604 controls. This led to the identification of a new risk locus for BAV on chromosome 3q29.
Objectives: The aim of this study was to analyse the outcome of patients between 50 and 69 years of age undergoing biological or mechanical aortic valve replacement.
Methods: Data were collected from the German Aortic Valve Registry. Data were analysed regarding baseline characteristics and outcome parameters such as 5-year survival, stroke and reintervention.
Objectives: Surgical aortic valve replacement (SAVR) in small annuli carries an elevated risk for the patient-prosthesis mismatch. In this study, we systematically investigated the influence of different implantation techniques including annular enlargement (AE) on the functional result after SAVR in small annuli using a standardized ex vivo model.
Methods: SAVR using the PERIMOUNT Magna Ease® (PME) 21 mm was performed in small porcine aortic roots using 4 implantation techniques: non-everting pledgeted (NE) suture, single interrupted (SI) suture, continuous suture (CS), figure-of-8 (F8) suture, as well as the PME 23 mm after AE using the Nunez method and the NE suture technique (PME23 AE).
Objectives: Transcatheter aortic valve-in-valve (ViV) procedures are increasingly performed for the treatment of degenerated surgical aortic valves with a high risk for a redo operation. For an optimal functional result, precise positioning of the transcatheter heart valve (THV) inside the SHV is crucial. The aim of this study was to systematically investigate the impact of implantation depth on the functional result after a ViV procedure in a standardized in vitro setting.
View Article and Find Full Text PDFThe treatment of aortic valve disease in young patients is still a major clinical challenge, as the pre-eminent emphasis is on durability and long-term outcomes beyond 10 to 15 years, sometimes >20 to 30 years. The Ross procedure uses the autologous pulmonary valve as an aortic valve substitute and aims to improve valve durability while avoiding anticoagulation and therefore achieve a sustained long-term result with regard to survival, valve functionality, and quality of life. However, this procedure is technically demanding and only performed at a low frequency.
View Article and Find Full Text PDFHuman pluripotent stem cells (hPSCs) hold great promise for applications in cell therapy and drug screening in the cardiovascular field. Bone morphogenetic protein 4 (BMP4) is key for early cardiac mesoderm induction in hPSC and subsequent cardiomyocyte derivation. Small-molecular BMP4 mimetics may help to standardize cardiomyocyte derivation from hPSCs.
View Article and Find Full Text PDFObjectives: We investigated the Ozaki procedure using a single interrupted suture technique (SST) and compared this with the standard continuous suture technique (CST) with regard to hydrodynamic valve performance. In addition, both techniques were compared with the native aortic valve (NAV).
Methods: Effective orifice area, mean pressure gradient and leakage volume were evaluated in the NAV as well as after an Ozaki procedure using SST or CST in fresh swine aortic roots using a mock circulation loop.
Eur J Cardiothorac Surg
November 2021
Objectives: To determine the 5-year outcome in patients treated by isolated transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (sAVR)-a prospective observational cohort study.
Methods: A total of 18 010 patients were included (n = 8942 TAVI and n = 9068 sAVR) in the German Aortic Valve Registry (GARY) who were treated in 2011 and 2012 at 92 sites in central Germany. Eligible patients with TAVI and sAVR were matched using propensity scores in a nearest-neighbour approach.
Background: Treatment of aortic-valve disease in young patients still poses challenges. The Ross procedure offers several potential advantages that may translate to improved long-term outcomes.
Objectives: This study reports long-term outcomes after the Ross procedure.
Objectives: This study sought to compare patient characteristics, procedural outcomes, and valve hemodynamics of surgical aortic valve replacement (SAVR) with current-generation rapid-deployment valves (RDVs) versus transcatheter aortic valve replacement (TAVR) with current-generation transcatheter heart valves (THVs).
Background: The patient population currently treated with RDVs may have potential similarities with the current TAVR population, but comparative studies in a large patient population remain scarce.
Methods: A total of 16,473 patients who underwent isolated SAVR using current-generation RDVs or isolated transfemoral TAVR with current-generation THVs between 2011 and 2017 were enrolled into the German Aortic Valve Registry.
Background: Bicuspid aortic stenosis accounts for almost 50% of patients undergoing surgical aortic valve replacement in the younger patients. Expanding the indication of transcatheter aortic valve replacement (TAVR) toward lower-risk and younger populations will lead to increased use of TAVR for patients with bicuspid aortic valve (BAV) stenosis despite the exclusion of bicuspid anatomy in all pivotal clinical trials.
Objectives: This study sought to evaluate the association of BAV morphology and outcomes of TAVR with the new-generation devices.
Background: Anatomically pre-shaped sinus prostheses (SP) were developed to mimic the aortic sinus with the goal to preserve near physiological hemodynamic conditions after valve-sparing aortic root replacement. Although SP have shown more physiological flow patterns, a comparison to straight tube prosthesis and the analysis of derived quantitative parameters is lacking. Hence, this study sought to analyze differences in aortic wall shear stress (WSS) between anatomically pre-shaped SP, conventional straight tube prostheses (TP), and age-matched healthy subjects) using time-resolved 3-dimensional flow cardiovascular magnetic resonance (4D Flow CMR).
View Article and Find Full Text PDFMitral valve annuloplasty has been the gold standard for treatment of functional mitral valve regurgitation. However, annuloplasty for functional mitral regurgitation may cause augmented posterior leaflet tethering, which results in functional anterior prolapse. Herein we added papillary muscle heads focalization for such patients.