Publications by authors named "Bryan W Cunitz"

Article Synopsis
  • The study evaluated the effectiveness of ultrasonic propulsion in helping patients with residual kidney stone fragments clear them and reduce the chance of relapse over five years.
  • It involved a randomized controlled trial with 82 adult participants, where those receiving ultrasonic propulsion experienced a significantly longer time to relapse and a lower relapse rate compared to the control group.
  • The treatment also led to a higher rate of fragment passage within three weeks, and while some adverse events were reported, they were mostly mild and resolved on their own, indicating that the procedure carries minimal risk.
View Article and Find Full Text PDF

Objectives: The number and distribution of lung ultrasound (LUS) imaging artifacts termed B-lines correlate with the presence of acute lung disease such as infection, acute respiratory distress syndrome (ARDS), and pulmonary edema. Detection and interpretation of B-lines require dedicated training and is machine and operator-dependent. The goal of this study was to identify radio frequency (RF) signal features associated with B-lines in a cohort of patients with cardiogenic pulmonary edema.

View Article and Find Full Text PDF

Pulsed high-intensity focused ultrasound (pHIFU) uses nonlinearly distorted millisecond-long ultrasound pulses of moderate intensity to induce inertial cavitation in tissue without administration of contrast agents. The resulting mechanical disruption permeabilizes the tissue and enhances the diffusion of systemically administered drugs. This is especially beneficial for tissues with poor perfusion such as pancreatic tumors.

View Article and Find Full Text PDF

Purpose: Our goal was to test transcutaneous focused ultrasound in the form of ultrasonic propulsion and burst wave lithotripsy to reposition ureteral stones and facilitate passage in awake subjects.

Materials And Methods: Adult subjects with a diagnosed proximal or distal ureteral stone were prospectively recruited. Ultrasonic propulsion alone or with burst wave lithotripsy was administered by a handheld transducer to awake, unanesthetized subjects.

View Article and Find Full Text PDF

Purpose: We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses.

Materials And Methods: This was a prospective multi-institutional feasibility study recruiting subjects undergoing clinical ureteroscopy (URS) for at least 1 stone ≤12 mm as measured on computerized tomography. During the planned URS, either before or after ureteroscope insertion, BWL was administered with a handheld transducer, and any stone fragmentation and tissue injury were observed.

View Article and Find Full Text PDF

Background: High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required.

View Article and Find Full Text PDF

Burst wave lithotripsy (BWL) is a technology under clinical investigation for non-invasive fragmentation of urinary stones. Under certain ranges of ultrasound exposure parameters, this technology can cause cavitation in tissue leading to renal injury. This study sought to measure the focal pressure amplitude needed to cause cavitation in vivo and determine its consistency in native tissue, in an implanted stone model and under different exposure parameters.

View Article and Find Full Text PDF

Boiling histotripsy (BH) uses millisecond-long ultrasound (US) pulses with high-amplitude shocks to mechanically fractionate tissue with potential for real-time lesion monitoring by US imaging. For BH treatments of abdominal organs, a high-power multielement phased array system capable of electronic focus steering and aberration correction for body wall inhomogeneities is needed. In this work, a preclinical BH system was built comprising a custom 256-element 1.

View Article and Find Full Text PDF

To test the effectiveness (Participant A) and tolerability (Participant B) of urinary stone comminution in the first-in-human trial of a new technology, burst-wave lithotripsy (BWL). An investigational BWL and ultrasonic propulsion system was used to target a 7-mm kidney stone in the operating room before ureteroscopy (Participant A). The same system was used to target a 7.

View Article and Find Full Text PDF

In certain medical applications, transmitting an ultrasound beam through the skin to manipulate a solid object within the human body would be beneficial. Such applications include, for example, controlling an ingestible camera or expelling a kidney stone. In this paper, ultrasound beams of specific shapes were designed by numerical modeling and produced using a phased array.

View Article and Find Full Text PDF

The color Doppler ultrasound twinkling artifact has been found to improve detection of kidney stones with ultrasound; however, it appears on only ∼60% of stones. Evidence from ex vivo kidney stones suggests twinkling arises from microbubbles stabilized in crevices on the stone surface. Yet it is unknown whether these bubbles are present on stones in humans.

View Article and Find Full Text PDF

Our goals were to validate stone comminution with an investigational burst wave lithotripsy (BWL) system in patient-relevant conditions and to evaluate the use of ultrasonic propulsion to move a stone or fragments to aid in observing the treatment endpoint. The Propulse-1 system, used in clinical trials of ultrasonic propulsion and upgraded for BWL trials, was used to fragment 46 human stones (5-7 mm) in either a 15-mm or 4-mm diameter calix phantom in water at either 50% or 75% dissolved oxygen level. Stones were paired by size and composition, and exposed to 20-cycle, 390-kHz bursts at 6-MPa peak negative pressure (PNP) and 13-Hz pulse repetition frequency (PRF) or 7-MPa PNP and 6.

View Article and Find Full Text PDF

Ultrasonic propulsion is an investigative modality to noninvasively image and reposition urinary stones. Our goals were to test safety and effectiveness of new acoustic exposure conditions from a new transducer, and to use simultaneous ureteroscopic and ultrasonic observation to quantify stone repositioning. During operation, ultrasonic propulsion was applied transcutaneously, whereas stone targets were visualized ureteroscopically.

View Article and Find Full Text PDF

Burst wave lithotripsy is an experimental technology to noninvasively fragment kidney stones with focused bursts of ultrasound (US). This study evaluated the safety and effectiveness of specific lithotripsy parameters in a porcine model of nephrolithiasis. A 6- to 7-mm human kidney stone was surgically implanted in each kidney of three pigs.

View Article and Find Full Text PDF

Multielement focused ultrasound phased arrays have been used in therapeutic applications to treat large tissue volumes by electronic steering of the focus, to target multiple simultaneous foci, and to correct aberration caused by inhomogeneous tissue pathways. There is an increasing interest in using arrays to generate more complex beam shapes and corresponding acoustic radiation force patterns for manipulation of particles such as kidney stones. Toward this end, experimental and computational tools are needed to enable accurate delivery of desired transducer vibrations and corresponding ultrasound fields.

View Article and Find Full Text PDF

Purpose: Burst wave lithotripsy (BWL) is a new technology in development to fragment urinary stones. Ultrasonic propulsion (UP) is a separate technology under investigation for displacing stones. We measure the effect of propulsion pulses on stone fragmentation from BWL.

View Article and Find Full Text PDF

A noninvasive ultrasound (US) system to facilitate the passage of small kidney stones has been developed. The device incorporates a software-based US platform programmed with brightness mode and Doppler for visualizing stones, plus long duration focused pulses for repositioning stones using the same transducer. This paper characterizes the acoustic outputs of the ultrasonic propulsion device.

View Article and Find Full Text PDF

Objective: To evaluate in more detail the effectiveness of a new designed more efficient ultrasonic propulsion for large stones and specific stone compositions in a tissue phantom model. In the first clinical trial of noninvasive ultrasonic propulsion, urinary stones of unknown compositions and sizes up to 10 mm were successfully repositioned.

Materials And Methods: The study included 8- to 12-mm stones of 4 different primary compositions (calcium oxalate monohydrate, ammonium acid urate, calcium phosphate, and struvite) and a renal calyx phantom consisting of a 12 mm × 30 mm well in a 10-cm block of tissue-mimicking material.

View Article and Find Full Text PDF

Purpose: Greater visual contrast between calculi and tissue would improve ultrasound (US) imaging of urolithiasis and potentially expand clinical use. The color Doppler twinkling artifact has been suggested to provide enhanced contrast of stones compared with brightness mode (B-mode) imaging, but results are variable. This work provides the first quantitative measure of stone contrast in humans for B-mode and color Doppler mode, forming the basis to improve US for the detection of stones.

View Article and Find Full Text PDF

Purpose: In the first-in-human trial of ultrasonic propulsion, subjects passed collections of residual stone fragments repositioned with a C5-2 probe. Here, effectiveness and safety in moving multiple fragments are compared between the C5-2 and a custom (SC-50) probe that produces a longer focal beam and burst duration.

Materials And Methods: Effectiveness was quantified by the number of stones expelled from a calyx phantom consisting of a 30-mm deep, water-filled well in a block of tissue mimicking material.

View Article and Find Full Text PDF

Purpose: Burst wave lithotripsy (BWL) is a transcutaneous technique with potential to safely and effectively fragment renal stones. Preclinical investigations of BWL require the assessment of potential renal injury. This study evaluates the capabilities of real-time ultrasound and MRI to detect and evaluate BWL injury that was induced in porcine kidneys.

View Article and Find Full Text PDF

Newer imaging and therapeutic ultrasound technologies may benefit from in situ pressure levels higher than conventional diagnostic ultrasound. One example is the recently developed use of ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.

View Article and Find Full Text PDF

Bone demineralization, dehydration and stasis put astronauts at increased risk of forming kidney stones in space. The color-Doppler ultrasound "twinkling artifact," which highlights kidney stones with color, can make stones readily detectable with ultrasound; however, our previous results suggest twinkling is caused by microbubbles on the stone surface which could be affected by the elevated levels of carbon dioxide found on space vehicles. Four pigs were implanted with kidney stones and imaged with ultrasound while the anesthetic carrier gas oscillated between oxygen and air containing 0.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to measure the accuracy of stone-specific algorithms (S-mode) and the posterior acoustic shadow for determining kidney stone size with ultrasound (US) in vivo.

Materials And Methods: Thirty-four subjects with 115 renal stones were prospectively recruited and scanned with S-mode on a research US system. S-mode is gray-scale US adjusted to enhanced stone contrast and resolution by minimizing compression and averaging, and increasing line density and frequency.

View Article and Find Full Text PDF

Transcutaneous focused ultrasound (US) is used to propel kidney stones using acoustic radiation force. It is important to estimate the level of heating generated at the stone/tissue interface for safety assessment. An in-vitro experiment is conducted to measure the temperature rise in a tissue-mimicking phantom with an embedded artificial stone and subjected to a focused beam from an imaging US array.

View Article and Find Full Text PDF