Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants and peri-implant tissues.Aim: To evaluate the impact of implant-supported removable prostheses bar designs in fully edentulous arch (in the maxilla and/or mandibula), with 4 implants or more, on the peri-implant soft and hard tissues.
View Article and Find Full Text PDFProsthetic treatment for elderly patients is a challenge that addresses both patient- and technology-mediated dental concerns. This report describes the fabrication of a cobalt-chromium crown without an impression using a digitized and scanned temporary crown to provide excellent integration.
View Article and Find Full Text PDFInt J Prosthodont
February 2018
To understand the relationship between surface morphology and proton conduction of polymer electrolyte thin films, perfluorinated ionomer Nafion® thin films were prepared on different substrates such as glassy carbon (GC), hydrophilic-GC (H-GC), and platinum (Pt) as models for the ionomer film within a catalyst layer. Atomic force microscopy coupled with an electrochemical (e-AFM) technique revealed that proton conduction decreased with film thickness; an abrupt decrease in proton conductance was observed when the film thickness was less than ca. 10 nm on GC substrates in addition to a significant change in surface morphology.
View Article and Find Full Text PDFJ Clin Pediatr Dent
February 2010
Unlabelled: A variety of alternatives to amalgam are now available for use in Class I and Class II restorations in primary teeth, including glass ionomer cements, compomers and resin modified glass ionomer cements (RMGIC).
Objectives: This study evaluated the two-year clinical performance of three restorative dental materials: A resin modified glass ionomer cement (Fuji IILC), a compomer (Dyract AP) and a high viscosity glass ionomer cement (Fuji IX), in primary molars of pediatric patients with high caries risk activity and compared these results to those reported for amalgam restorations.
Study Design: One hundred and forty nine Class I and Class II cavities in 45 patients aged 6 to 8 years were restored with compomer, glass ionomer cements and amalgam.
Purpose: The passive fit of a superstructure on implant abutments is essential to success. One source of error when using a tapered cone-screw internal connection may be the difference between the tightening torque level applied to the abutments by the laboratory technician compared to that applied by the treating clinician. The purpose of this study was to measure the axial displacement of tapered cone-screw abutments into implants and their replicas as a function of the tightening torque level.
View Article and Find Full Text PDFAim: To evaluate the reliability of professional qualitative scoring methods used in evaluating aesthetic results after root coverage therapy and to evaluate the relationship between subjective and objective measurements.
Material And Methods: A review panel of seven professional and non-professional, trained and untrained observers used photographic records to assess the overall cosmetic results of 162 root coverage surgical procedures in 133 patients (mean follow-up 17.51+/-17.
J Biomed Mater Res B Appl Biomater
January 2009
Recent studies have shown that the particle size of fillers used for the reinforcement of dental resin composites should be multimodally distributed, in which micron-sized fillers are mixed with nanoparticles so as to achieve a higher filler level in the resin, and should be kept well dispersed so as to be functionalized by a silane. In this study, porous alumina monoliths with high specific surface area, measured by the Brunauer-Emmett-Teller (BET) method, were obtained using a novel preparation method. Structure and surface reactivity have been investigated as functions of temperature and chemical treatments.
View Article and Find Full Text PDFSchweiz Monatsschr Zahnmed
June 2008
The purpose of the present study conducted in a school in Lebanon was to evaluate the one-year clinical performance of a polyacid-modified resin composite (PMC), a resin-modified glass ionomer cement (RMGIC), a high viscosity GIC (HVGIC) and an amalgam (Amlg). Hundred and forty-nine class I and class II cavities in 45 patients aged 6 to 8 years, with a high caries risk activity, were restored with these materials. Restorations were evaluated by two examiners at baseline, 6 and 12 months, according to USPHS criteria.
View Article and Find Full Text PDFObjectives: The purpose of this study was to evaluate the adhesion to dental ceramic by Vickers indenter methodology. This technique allows the creation of adhesive fractures and determines the influence of the surface treatment on adhesive capacities.
Methods: A single bond adhesive system (One Step Bisco) was applied to ceramic Vitapan 3D Master CE 0124 samples.
The choice of the most suitable orthodontic wire for each stage of treatment requires estimation of the forces generated. In theory, the selection of wire sequences should initially utilize a lower flexural rigidity; thus clinicians use smaller round cross-sectional dimension wires to generate lighter forces during the preliminary alignment stage. This assessment is true for conventional alloys, but not necessarily for superelastic nickel titanium (NiTi).
View Article and Find Full Text PDFThe purpose of this study was to compare the effects of time on the flexural strength of a resin-reinforced glass ionomer and a composite adhesive system, specifically at three time frames corresponding to the three stages of polymerization of Fuji Ortho LC. Ten rectangular specimens of each material were prepared in a metal mold (25 x 2 x 2 mm) and then stored at 37 degrees C and 100% humidity in an incubator. Six test groups were created, in which each specimen was fractured using a 3-point-bending test at a crosshead speed of 0.
View Article and Find Full Text PDF