This study evaluated some physicochemical properties of an experimental tricalcium silicate-based cement (ETSC) indicated for use as pulp capping or endodontic repair material; Biodentine (BD) and White MTA-Angelus (MTA) cements served as comparators. Setting time, radiopacity, sorption, and solubility were determined according to ISO 6876/2012 and compressive strength according to ISO 9917-1/2019. pH and calcium ion release capacity were also assessed.
View Article and Find Full Text PDFAust Endod J
December 2024
The influence of ultrasonic activation (UA) on the physicochemical properties of setting time (n = 5), volumetric stability (n = 10), alkalizing activity/calcium ions release (pH/Ca) (n = 10) and calcium/phosphate-rich substance formation in simulated body fluid (Hank's balanced salt solution; HBSS) of three cements was evaluated: white MTA-Angelus (MTA), MTA Repair HP (MTAHP) and Biodentine (BIO). It was observed that UA influenced the setting times (min) distinctly, delaying the initial setting time of MTA (40.8/64.
View Article and Find Full Text PDFIntroduction: The purpose of this study was to evaluate whether the mixing method of AH Plus Jet sealer affects its physicochemical and mechanical properties.
Methods: The properties of AH Plus Jet sealer were analyzed when mixed using either the Auto Mix Tip or manual mixing. The evaluated properties included radiopacity (n = 5), initial and final setting times (n = 5), flow (n = 5), and solubility (n = 3), following specifications outlined in ISO 6876/2012 and ADA Nº 57/2000.
J Endod
May 2023
Introduction: The obturation quality of the mandibular molar mesial canals and isthmuses with two thermoplastic techniques, ultrasonic vertical condensation (UVC) and continuous wave of condensation (CWC), was evaluated using computed microtomography (μCT).
Methods: Thirty-six human mandibular molars had been previously scanned and analyzed using μCT for mesial roots with morphologically similar isthmuses for this study. Coronal access and confirmation of foraminal patency were performed, and the actual length of the teeth was established using a clinical microscope (40X magnification).
This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.
View Article and Find Full Text PDFJ Mater Sci Mater Med
November 2021
This study aimed to investigate the antimicrobial and biological properties of Ambroxol associated with glycerin (GLI), propylene glycol (PG), and polyethylene glycol (PEG) as a possible vehicle for an experimental tricalcium silicate sealer, with the intention of developing a new biomaterial. Mouse undifferentiated dental pulp cells (OD-21) were cultured, and the effects of different association on cell proliferation and inflammatory cytokine production were investigated. Antimicrobial adhesion of Enterococcus faecalis to setting sealers at 2 h was evaluated.
View Article and Find Full Text PDFSixty moderately curved canals of mandibular molars classified as Vertucci's type IV canal configuration were selected by micro-CT 1174. The teeth were divided into two groups according to the kinematics used, whether reciprocating or rotary motion (n=30, totaling 60 mesial root canals). The instruments used to perform the glide path procedures had identical features (0.
View Article and Find Full Text PDFThis study aimed to evaluate the influence of large apical preparations with Reciproc (REC), Hyflex CM (HCM) and Twisted File Adaptive (TFA) systems using micro-computed tomography (MCT). Ninety mesiobuccal (MB) and distobuccal (DB) root canals of maxillary molars (n = 45) were scanned using MCT before and after the shaping procedures. The root canals (n = 15) were prepared until REC 40.
View Article and Find Full Text PDFThe aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci's type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1).
View Article and Find Full Text PDFThe aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files.
View Article and Find Full Text PDFClin Oral Investig
November 2019
Objectives: The effect of ultrasonic agitation (UA) on bond strength and adaptation of cervical plugs prepared with MTA Angelus (MTA), MTA Repair HP (MTAHP), and Biodentine (BIO) was evaluated. Dentin discoloration caused by the materials/treatment was also assessed.
Materials And Methods: Seventy-two single rooted teeth were divided into six groups depending on the materials/treatment.
J Conserv Dent
January 2018
Aim: The aim of this study was compare the capacity of different irrigation protocols for debris removal from artificial grooves and assess the effectiveness of Easy Clean used in different kinematics by means of micro-CT.
Methodology: Fifty acrylic prototyped maxillary incisors were instrumented and included in a muffle. The specimens were longitudinally sectioned, and a longitudinal groove was made on the inner surface of the root canal in one of hemisections, and the dentin debris was inserted into the grooves.
To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF.
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate the influence of humidity on the intra-tubular penetration, bond strength and failure mode associated with AH Plus (AH) and MTA Fillapex (MTAF) sealers.
Methods: For this analysis, an apparatus was created to maintain the humidity of the specimens. Sixty bovine single-rooted teeth with similar anatomy were used.
Although Root ZX is considered the gold standard electronic foramen locator (EFL), two variations of this device were launched, however without different operating mechanisms. This investigation aims to evaluate the precision of Root ZX (RZX), Root ZX II (RII), and Root ZX Mini (RM) EFLs. After access cavity preparation, 32 mandibular single rooted human premolars had their real length measured with the aid of a #15 K-type manual file under magnification (25x).
View Article and Find Full Text PDFJ Appl Oral Sci
April 2017
A wide range of accidents might happen during the treatment of the root canal system, where the instrument separation is one of the most unpleasant occurrences. Several techniques have been developed to facilitate the removal of the fragments; however, they generally require specific devices that not always are available to the clinician. The aim of this case report is to present a simple alternative technique to remove from the root canals manual instruments fractured during the treatment.
View Article and Find Full Text PDFThe present study evaluated the efficacy of electronic foramen locators (EFLs) to control root canal working length during rotary instrumentation and to assess possible reliability variations of different working lengths. Forty-eight human mandibular bicuspids were randomly divided in 2 groups according to the used device, Root ZX II (RZX) and Propex II (PRO). They were further subdivided in 2 subgroups according to the root canal preparation level (0.
View Article and Find Full Text PDFIntroduction: The objective of the present study was to evaluate the accuracy of electronic foramen locators (EFLs), Root ZX II (RZX; J. Morita, Tokyo, Japan), Propex II (Dentsply Maillefer, Ballaigues, Switzerland), and Apex ID (AID; SybronEndo, Glendora, CA), in root canals with an obstructed apical foramen (OAF) and to compare them with those 1.0 mm short of the apical foramen (AF; -1.
View Article and Find Full Text PDFIntroduction: The objective of the present study was to evaluate ex vivo the maintenance of the apical limit during instrumentation with the Root ZX (J Morita, Tokyo, Japan) and VDW Gold (VDW GbmH, Munich, Germany) hybrid devices in rotary and reciprocating modes and determine the possible function variations of different preparation levels (0.0 mm and -1.0 mm).
View Article and Find Full Text PDFThe aim of this study was to compare in vivo the accuracy of two electronic foramen locators (EFLs) based on different operation systems - Root ZX and Propex II. Ten healthy adult patients needing premolar extractions due to orthodontic reasons participated in the study, providing a sample of 17 noncarious, non-restored, vital teeth (n= 24 canals). After coronal access preparation and cervical preflaring and prior to tooth extraction, the root canal length was measured alternating the two EFLs.
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen.
Material And Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.
This study evaluated the accuracy of three electronic apex locators (Root ZX, Novapex, and Justy II) in root canal length determinations using different apical file sizes, considering the apical constriction (AC) and the major foramen (MF) as anatomic references. The diameter of the apical foramina of 40 single-rooted teeth was determined by direct visual measurement and the master apical file was established. Electronic measurements were then performed using 3 instruments: the selected master apical file (adjusted file), one size smaller (intermediate file), and two sizes smaller (misfit file).
View Article and Find Full Text PDFObjectives: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura) using the fluid filtration method.
Material And Methods: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen.
This study evaluated the increase of the instrumented area and dentin thickness in the mesial and distal aspects of mesial canals of mandibular molars after the use of Gates Glidden (GG), LA Axxess (LA) and Orifice Shaper (OS) instruments. A total of 53 canals from 27 mandibular molars were embedded in resin and divided into 3 groups. The roots were sectioned 3 mm below the cementoenamel junction and the images were captured before and after instrumentation.
View Article and Find Full Text PDF