Background: Accurate quantification of right ventricular (RV) volumes and function is crucial for the management of congenital heart diseases.
Aims: We aimed to assess the feasibility and accuracy of bedside analysis using new RV quantification software from three-dimensional transthoracic echocardiography in children with or without congenital heart disease, and to compare measurements with cardiac magnetic resonance imaging.
Methods: We included paediatric patients with congenital heart disease (106 patients) responsible for RV volume overload and a control group (30 patients).
Magnetic resonance imaging (MRI) is being increasingly used for imaging suspected recurrence in prostate cancer therapy. Functional MRI with diffusion and perfusion imaging has the potential to demonstrate local recurrence even at low PSA value. Detection of recurrence can modify the management of postprostatectomy biochemical recurrence.
View Article and Find Full Text PDFGlomus tumor are rare mesenchymal neoplasm, belonging to the pericytic (perivascular) tumor family, witch recent molecular characterization has allowed highlight recurrent molecular abnormalities. In fact, glomus tumor involves frequent MIR143-NOTCH gene fusion whereas others pericytic tumor (myopericytoma and myofibroma) involve mutations of PDGFRB gene. Glomus tumor are usually developed in superficial localization.
View Article and Find Full Text PDFBackground/purpose: Dose-escalated external beam radiotherapy (RT) is effective in the control of prostate cancer but is associated with a greater incidence of rectal adverse events. We assessed the dosimetric gain and safety profile associated with implantation of a new biodegradable rectal spacer balloon.
Materials/methods: Patients scheduled for image-guided, intensity-modulated RT for intermediate-risk prostate cancer were prospectively included in the French multicenter BioPro-RCMI-1505 study (NCT02478112).
We present the case, with tomographic three-dimensional reconstructions, of an adult patient affected by congenital absence of one pulmonary valve cusp with completely normal morphology of the other two cusps.
View Article and Find Full Text PDFUpfront MRI is taking the lead in the diagnosis of clinically significant prostate cancer, while few image-guided biopsies (IGBs) fail to demonstrate clinically significant prostate cancer. The added value of innovative biomarkers is not confirmed in this context. We analysed SelectMDx-v2 (MDx-2) in a cohort of upfront MRI and image-guided biopsy patients.
View Article and Find Full Text PDFObjective: To analyse the accuracy of high preoperative PSA levels for predicting transitional zone incidental PCa (TZ-PCa) in men with very large prostates.
Materials And Methods: Perioperative data from 375 consecutive patients who underwent endoscopic enucleation of the prostate (EEP) for benign prostatic obstruction between July 2013 and December 2018 were retrospectively reviewed. Patients were stratified into three groups according to the preoperative PSA level: low-PSA (< 4 ng/mL), intermediate-PSA (4 ≤ PSA < 10 ng/mL) and high-PSA (≥ 10 ng/mL).
Background: Intra-individual heterogeneity of cardiac exposure is an issue in breast cancer (BC) radiotherapy that was poorly considered in previous cardiotoxicity studies mainly based on mean heart dose (MHD). This dosimetric study analyzes the distribution of individually-determined radiation doses to the heart and its substructures including coronary arteries and evaluate whether MHD is a relevant surrogate parameter of dose for these substructures.
Methods: Data were collected from the BACCARAT prospective study that included left or right unilateral BC patients treated with 3D-Conformal Radiotherapy (RT) between 2015 and 2017 and followed-up for 2 years with repeated cardiac imaging examinations.
Aims: The aim of this study was to assess the predictive value of simulation based on 3D-printed models before left atrial appendage occlusion (LAAO) for peri-device leaks (PDL) and the impact on procedural outcomes compared to conventional imaging.
Methods And Results: Seventy-six patients referred for LAAO with double disc device underwent construction of a 3D-printed LA model using flexible photopolymer resin. An implant simulation was performed retrospectively in Group 1 (55 patients), blinded to implanted device size, and prospectively in Group 2 (21 patients).
Purpose To measure the precision in placement of a biopsy needle in a magnetic resonance (MR) imaging-detected target with transrectal ultrasonography (US), to document the clinical relevance of precision, and to report on the precision of cognitive and software-based registrations. Materials and Methods This prospective study was approved by the institutional review board and performed between June 2013 and September 2013. Patients provided informed verbal consent.
View Article and Find Full Text PDFPurpose: In men with suspicion of prostate cancer the standard of cancer detection is transrectal ultrasound guided 10 to 12-core systematic biopsy. The targeted biopsy only strategy using magnetic resonance imaging-transrectal ultrasound image registration is gaining in popularity. We assessed the noninferiority of targeted vs systematic biopsy.
View Article and Find Full Text PDFBackground: Radiotherapy (RT) for breast cancer presents a benefit in terms of reducing local recurrence and deaths resulting from breast cancer but it can lead to secondary effects due to the presence of neighboring cardiac normal tissues within the irradiation field. Breast RT has been shown to be associated with long-term increased risk of heart failure, coronary artery disease, myocardial infarction and finally cardiovascular death more than 10 years after RT. However, there is still a lack of knowledge for early cardiotoxicity induced by breast RT that can appear long before the onset of clinically significant cardiac events.
View Article and Find Full Text PDFPurpose: To compare the diagnostic performance of the magnetic resonance (MR) imaging-based Prostate Imaging Reporting and Data System (PI-RADS) and a Likert scale in the detection of prostate cancer in a cohort of patients undergoing initial prostate biopsy.
Materials And Methods: This institutional review board-approved two-center prospective study included 118 patients with normal digital rectal examination (DRE) results but elevated prostate-specific antigen (PSA) levels (4-20 ng/mL) who were referred for initial prostate biopsies and had one suspicious (Likert scale score, ≥3) focus at prebiopsy 1.5-T multiparametric MR imaging performed with T2-weighted, diffusion-weighted [DW], and dynamic contrast material-enhanced imaging.
Purpose: To assess the learning curves for the intra-operative parameters of the GreenLight™ 180-W XPS for photoselective vaporization of the prostate (PVP).
Methods: A prospective study was conducted on 200 men who underwent PVP using the GreenLight™ 180-W XPS over 20 months. The population was divided into four consecutive equal groups.
Background: Accurate quantification of aortic valve stenosis (AVS) is needed for relevant management decisions. However, transthoracic Doppler echocardiography (TTE) remains inconclusive in a significant number of patients. Previous studies demonstrated the usefulness of phase-contrast cardiovascular magnetic resonance (PC-CMR) in noninvasive AVS evaluation.
View Article and Find Full Text PDFAlagille syndrome is a rare congenital multisystem disorder that may involve heart disease and pulmonary or peripheral artery stenosis. We report the clinical and radiological presentation of five adult patients with Alagille syndrome, hypertension and renal artery stenosis. All had systolic hypertension and a narrowing of the abdominal aorta, corresponding to a secondary midaortic syndrome.
View Article and Find Full Text PDFPurpose: To report a case of retrograde acute Stanford type A aortic dissection treated without hypothermic circulatory arrest.
Case Report: A 55-year-old man presented with a retrograde acute type A aortic dissection with an entry tear 30 mm below the left subclavian artery. A concurrent emergent endovascular and surgical treatment was performed, excluding the entry tear with retrograde delivery of a stent-graft and replacing the ascending aorta with a Dacron tube without circulatory arrest.